다음을 통해 공유


ParametersInReadyEventArgs Class

NOTE: This API is now obsolete.

Provides an array of parameter values to the ParametersInReadyevent of the IParametersInProvider interface.

Inheritance Hierarchy

System.Object
  System.EventArgs
    Microsoft.SharePoint.WebPartPages.Communication.ParametersInReadyEventArgs

Namespace:  Microsoft.SharePoint.WebPartPages.Communication
Assembly:  Microsoft.SharePoint (in Microsoft.SharePoint.dll)

Syntax

'Declaration
<ObsoleteAttribute("Use System.Web.UI.WebControls.WebParts.IWebPartParameters instead")> _
Public Class ParametersInReadyEventArgs _
    Inherits EventArgs
'Usage
Dim instance As ParametersInReadyEventArgs
[ObsoleteAttribute("Use System.Web.UI.WebControls.WebParts.IWebPartParameters instead")]
public class ParametersInReadyEventArgs : EventArgs

Examples

The following code example shows an overridden PartCommunicationMainmethod that creates an instance of the ParametersInReadyEventArgs class to send when the ParametersInReady event occurs. This code example is part of a larger example provided for the IParametersInProvider interface.

      ' Step #7: Implement the PartCommunicationMain() method.
      ' The PartCommunicationMain method is called by the Web Part 
      ' infrastructure on the client during the ASP.NET PreRender
      ' event to allow the part to pass its primary data to the other 
      ' connected parts.
      ' It is important to always fire either the ParametersInReady or 
      ' the NoParametersIn event. Some parts
      ' may not behave properly if they are left waiting for this 
      ' information.
      ' ParametersInReady should be fired to send the parameters.
      ' NoParametersIn should be fired to indicate that there is no 
      ' change in the parameters.
      Public Overrides Sub PartCommunicationMain()
            ' Ensure that all of the Web Part's controls are created.
            EnsureChildControls()

            'Check if connected
            If _connected Then
                ' Create the ParametersInReadyEventArgs object for the ParametersInReady event.
                Dim parametersInReadyEventArgs As New ParametersInReadyEventArgs()

                If _parametersReadyButtonClicked Then 'ParametersInReady Button was clicked

                    ' Set the parameter values to the text box values.
                    If Not (_fieldList Is Nothing) Then
                        parametersInReadyEventArgs.ParameterValues = New String(_fieldList.Length) {}

                        Dim index As Integer
                        For index = 0 To _fieldList.Length - 1
                            parametersInReadyEventArgs.ParameterValues(index) = _fontAttributeTextBox(index).Text
                        Next index

                        ' Fire the ParametersInReady event.
                        RaiseEvent ParametersInReady(Me, parametersInReadyEventArgs)
                        '_fieldList is null
                    Else
                        ' Fire the event.
                        RaiseEvent NoParametersIn(Me, New EventArgs())
                    End If
                    _parametersReadyButtonClicked = False
                ElseIf _noParametersInButtonClicked Then 'NoParametersIn Button was clicked                       
                    ' Fire the NoParametersIn event.
                    RaiseEvent NoParametersIn(Me, New EventArgs())
                    _noParametersInButtonClicked = False
                End If
            End If
        End Sub
// Step #7: Implement the PartCommunicationMain() method.
// The PartCommunicationMain method is called by the Web Part 
// infrastructure on the client during the ASP.NET PreRender
// phase to allow the part to pass its primary data to the other 
// connected parts.
// It is important to always fire either the ParametersInReady or the 
// NoParametersIn event. Some parts
// may not behave properly if they are left waiting for this 
// information.
// ParametersInReady should be fired to send the parameters.
// NoParametersIn should be fired to indicate that there is no change 
// in the parameters.

public override void PartCommunicationMain()
{
    // Ensure that all of the Web Part's controls are created.
    EnsureChildControls();

    // Check if connected.
    if(_connected)
    {
        // If there is a listener, fire the ParametersInReady event.
        if(ParametersInReady != null)
        {
            //Create the ParametersInReadyEventArgs object for the 
            //ParametersInReady event.
            ParametersInReadyEventArgs parametersInReadyEventArgs = new ParametersInReadyEventArgs();

            // If the ParametersInReady button was clicked.
            if(_parametersReadyButtonClicked)
            {
                // If there is a listener, fire the ParametersInReady 
                // event.
                if(ParametersInReady != null)
                {
                    //Set the parameter values to the text box values.
                    if (_fieldList != null)
                    parametersInReadyEventArgs.ParameterValues = new string[_fieldList.Length];

                    for (int index = 0; index < _fieldList.Length; index++)
                    {
                        parametersInReadyEventArgs.ParameterValues[index] = _fontAttributeTextBox[index].Text;
                    }

                    // Fire the ParametersInReady event.
                    ParametersInReady(this, parametersInReadyEventArgs);

                    _parametersReadyButtonClicked = false;
                }
            }
            // If the NoParametersIn button was clicked.
            else if(_noParametersInButtonClicked)
            {
                // If there is a listener, fire the NoParametersIn 
                // event.
                if(NoParametersIn != null)
                {
                    // Fire the event.
                    NoParametersIn(this, new EventArgs());

                    _noParametersInButtonClicked = false;
                }
            }
            // The user didn't click any button.
            else 
            {
               // If there is a listener, fire the NoParametersIn 
               // event.
                if(NoParametersIn != null)
                {
                    // Fire the event
                    NoParametersIn(this, new EventArgs());

                    _noParametersInButtonClicked = false;
                }
            }
        }
    }
}

Thread Safety

Any public static (Shared in Visual Basic) members of this type are thread safe. Any instance members are not guaranteed to be thread safe.

See Also

Reference

ParametersInReadyEventArgs Members

Microsoft.SharePoint.WebPartPages.Communication Namespace