Rediger

Del via


Avoiding naming conflicts

A naming conflict occurs when you try to create or use an identifier that was previously defined. In some cases, naming conflicts generate errors such as Ambiguous name detected or Duplicate declaration in current scope. Naming conflicts that go undetected can result in bugs in your code that produce erroneous results, especially if you don't explicitly declare all variables before first use.

You can avoid most naming conflicts by understanding the scoping, private module-level, and public module-level.

A naming conflict can occur when an identifier:

  • Is visible at more than one scoping level.
  • Has two different meanings at the same level.

For example, procedures in separate modules can have the same name. Therefore, you can define a procedure named MySub in modules named Mod1 and Mod2. No conflicts occur if each procedure is called only from other procedures in its own module. However, an error can occur if MySub is called from a third module, and no qualification is provided to distinguish between the two MySub procedures.

Most naming conflicts can be resolved by preceding each identifier with a qualifier that consists of the module name and, if necessary, a project name. For example:

YourProject.YourModule.YourSub MyProject.MyModule.MyVar

The preceding code calls the Sub procedure YourSub and passes MyVar as an argument. Use any combination of qualifiers to differentiate identical identifiers.

Visual Basic matches each reference to an identifier with the "closest" declaration of a matching identifier. For example, if MyID is declared Public in two modules in a project (Mod1 and Mod2), you can specify the MyID declared in Mod2 without qualification from within Mod2, but you must qualify it as Mod2.MyID to specify it in Mod1.

This is also true if Mod2 is in a different but directly referenced project. However, if Mod2 is in an indirectly referenced project, that is, a project referenced by the project you directly reference, references to the Mod2 variable named MyID must always be qualified with the project name. If you reference MyID from a third, directly referenced module, the match is made with the first declaration encountered by searching:

  • Directly referenced projects, in the order that they appear in the References dialog box of the Tools menu.
  • The modules of each project. Note that there is no inherent order to the modules in the project.

You can't reuse names of host-application objects, for example, R1C1 in Microsoft Excel, at different scoping levels.

Tip

Typical errors caused by naming conflicts include ambiguous names, duplicate declarations, undeclared identifiers, and procedures that are not found. By beginning each module with an Option Explicit statement to force explicit declarations of variables before they are used, you can avoid some potential naming conflicts and identifier-related bugs.

See also

Support and feedback

Have questions or feedback about Office VBA or this documentation? Please see Office VBA support and feedback for guidance about the ways you can receive support and provide feedback.