MSSQLSERVER_7984

Applies to: SQL Server

Details

Attribute Value
Product Name SQL Server
Event ID 7984
Event Source MSSQLSERVER
Component SQLEngine
Symbolic Name DBCC2_PRE_CHECKS_BAD_PAGE_TYPE
Message Text System table pre-checks: Object ID O_ID. Page P_ID has unexpected page type PAGETYPE. Check statement terminated because of an irreparable error.

Explanation

A page with a type other than DATA_PAGE was found in the data level of the specified object. This error is raised during the first phase of the DBCC CHECKDB command checks. During this phase, DBCC CHECKDB performs primitive checks on the data pages of critical system base tables.

Note

If any errors are found in the system tables, the errors cannot be repaired; therefore, the DBCC CHECKDB command ends immediately.

User Action

Look for Hardware Failure

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows system and application logs and the SQL Server error log to see whether the error occurred as the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware components to isolate the problem. Check to make sure that the system does not have write-caching enabled on the disk controller. If you suspect write-caching to be the problem, contact your hardware vendor.

Finally, you might find it useful to switch to a new hardware system. This switch may include reformatting the disk drives and reinstalling the operating system.

Restore from Backup

If the problem is not hardware related and a known clean backup is available, restore the database from the backup.

Run DBCC CHECKDB