Rediger

Del via


WM_NOTIFY message

Sent by a common control to its parent window when an event has occurred or the control requires some information.

Parameters

wParam

The identifier of the common control sending the message. This identifier is not guaranteed to be unique. An application should use the hwndFrom or idFrom member of the NMHDR structure (passed as the lParam parameter) to identify the control.

lParam

A pointer to an NMHDR structure that contains the notification code and additional information. For some notification messages, this parameter points to a larger structure that has the NMHDR structure as its first member.

Return value

The return value is ignored except for notification messages that specify otherwise.

Remarks

The destination of the message must be the HWND of the parent of the control. This value can be obtained by using GetParent, as shown in the following example, where m_controlHwnd is the HWND of the control itself.

NMHDR nmh;
nmh.code = CUSTOM_SELCHANGE;    // Message type defined by control.
nmh.idFrom = GetDlgCtrlID(m_controlHwnd);
nmh.hwndFrom = m_controlHwnd;
SendMessage(GetParent(m_controlHwnd), 
    WM_NOTIFY, 
    nmh.idFrom, 
    (LPARAM)&nmh);

Applications handle the message in the window procedure of the parent window, as shown in the following example, which handles the notification message sent by the custom control in the previous example.

INT_PTR CALLBACK DlgProc(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam)
{
    switch (message)
    {
    case WM_NOTIFY:
        switch (((LPNMHDR)lParam)->code)
        {
        case CUSTOM_SELCHANGE:
            if (((LPNMHDR)lParam)->idFrom == IDC_CUSTOMLISTBOX1)
            {
                ...   // Respond to message.
                return TRUE;
            }
            break; 
        ... // More cases on WM_NOTIFY switch.
        break;
        }
    ...  // More cases on message switch.
    }
    return FALSE;
}

Some notifications, chiefly those that have been in the API for a long time, are sent as WM_COMMAND messages. For more information, see Control Messages.

If the message handler is in a dialog box procedure, you must use the SetWindowLong function with DWL_MSGRESULT to set a return value.

For Windows Vista and later systems, the WM_NOTIFY message cannot be sent between processes.

Many notifications are available in both ANSI and Unicode formats. The window sending the WM_NOTIFY message uses the WM_NOTIFYFORMAT message to determine which format should be used. See WM_NOTIFYFORMAT for further discussion.

Requirements

Requirement Value
Minimum supported client
Windows Vista [desktop apps only]
Minimum supported server
Windows Server 2003 [desktop apps only]
Header
Winuser.h

See also

WM_NOTIFYFORMAT