Rediger

Del via


signal command

The signal command identifies a specified position in the workspace by sending the application an MM_MCISIGNAL message. Digital-video devices recognize this command. MCIAVI supports only one active signal at a time.

To send this command, call the mciSendString function with the lpszCommand parameter set as follows.

_stprintf_s(
  lpszCommand, 
  TEXT("signal %s %s %s"), 
  lpszDeviceID, 
  lpszSignalFlags, 
  lpszFlags
); 

Parameters

lpszDeviceID

Identifier of an MCI device. This identifier or alias is assigned when the device is opened.

lpszSignalFlags

One of the following flags.

Value Meaning
at position Specifies the frame to invoke a signal.
cancel Removes signals from the workspace. An individual signal is specified by using the "uservalue" flag. If the "uservalue" flag is not specified by using "cancel", the device cancels all signals. The "cancel" flag is incompatible with the "at", "every", and "return position" flags.
every interval Specifies the period of the signals. The interval value is specified in the current time format.If used with "at" position, signals are placed throughout the workspace with one signal mark placed at position.
Without the "at" flag, signals are placed throughout the workspace with one signal at the current position.
If this flag is omitted, only the position indicated by the "at" flag is marked.
If the interval value is less than the minimum frequency supported by a device, it will use its minimum value.
return position Indicates the device should send the position value instead of the "uservalue" identifier in the signaling message. The "uservalue" identifier can still be used to cancel or to redefine the signal marks.
uservalue id Specifies an identifier that is reported back with the signaling message. This identifier acts as an identifier that can be used with other signal commands to reference this signal setting. If omitted, the default value is zero.

lpszFlags

Can be "wait", "notify", "test", or a combination of these. For more information about these flags, see The Wait, Notify, and Test Flags.

Return Value

Returns zero if successful or an error otherwise.

Remarks

The window handle used for notification of command completion messages is also used for signaling.

Requirements

Requirement Value
Minimum supported client
Windows 2000 Professional [desktop apps only]
Minimum supported server
Windows 2000 Server [desktop apps only]

See also

MCI

MCI Command Strings

MM_MCISIGNAL