Disable-StorageEnclosureIdentification
Turns off the identification LED on a storage enclosure or the slots for individual disks.
Syntax
Disable-StorageEnclosureIdentification
[-FriendlyName] <String[]>
[-SlotNumbers <UInt32[]>]
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[<CommonParameters>]
Disable-StorageEnclosureIdentification
-UniqueId <String[]>
[-SlotNumbers <UInt32[]>]
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[<CommonParameters>]
Disable-StorageEnclosureIdentification
-InputObject <CimInstance[]>
[-SlotNumbers <UInt32[]>]
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[-PassThru]
[<CommonParameters>]
Description
The Disable-StorageEnclosureIdentification cmdlet turns off the identification LED on the specified storage enclosure and, optionally, on the slots for individual disks. Administrators typically use LEDs to locate a physical disk in an enclosure for removal or replacement. This cmdlet requires a storage enclosure that supports SCSI Enclosure Services (SES).
Examples
Example 1: Disable identification of an enclosure
PS C:\>Disable-StorageEnclosureIdentification -FriendlyName "E11"
This command disables identification for the enclosure named E11.
Example 2: Disable identification of specified slot numbers
PS C:\>Disable-StorageEnclosureIdentification -FriendlyName "E11" -SlotNumbers @(20, 14)
This command disables identification for the slots numbers 20 and 14 of the enclosure named E11.
Parameters
-AsJob
ps_cimcommon_asjob
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-CimSession
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSessionhttp://go.microsoft.com/fwlink/p/?LinkId=227967 or Get-CimSessionhttp://go.microsoft.com/fwlink/p/?LinkId=227966 cmdlet. The default is the current session on the local computer.
Type: | CimSession[] |
Aliases: | Session |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-FriendlyName
Specifies an array of friendly names. This cmdlet turns off the identification LEDs for the enclosures that the names specify or for slots that belong to the specified enclosures.
Type: | String[] |
Position: | 0 |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-InputObject
Specifies an array of storage enclosures as CimInstance objects. This cmdlet turns off the identification LEDs for the enclosures that the objects specify or for slots that belong to the specified enclosures. To obtain a storage enclosure object, use the Get-StorageEnclosure cmdlet.
Type: | CimInstance[] |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-PassThru
Returns an array of StorageEnclosure objects. By default, this cmdlet does not generate any output.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-SlotNumbers
Specifies an array of slot numbers. This cmdlet turns off the identification LEDs for the slots that the numbers identify.
Type: | UInt32[] |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-UniqueId
Specifies an array of IDs. This cmdlet turns off the identification LEDsfor the enclosures that the IDs specify or for slots that belong to the specified enclosures.
Type: | String[] |
Aliases: | Id |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Outputs
MSFT_StorageEnclosure[]
This cmdlet does not generate any output. If you specify the Passthru parameter, the cmdlet returns an array of MSFT_StorageEnclosure objects.
Related Links
Обратная связь
https://aka.ms/ContentUserFeedback.
Ожидается в ближайшее время: в течение 2024 года мы постепенно откажемся от GitHub Issues как механизма обратной связи для контента и заменим его новой системой обратной связи. Дополнительные сведения см. в разделеОтправить и просмотреть отзыв по