Share via


Set-SCLogicalSwitch

Mantıksal anahtarın özelliklerini Güncelleştirmeler.

Syntax

Set-SCLogicalSwitch
   [-VirtualSwitchExtensions <VirtualSwitchExtension[]>]
   [-Description <String>]
   [-EnableSriov <Boolean>]
   [-SwitchUplinkMode <SwitchUplinkMode>]
   [-MinimumBandwidthMode <BandwidthMode>]
   [-VMMServer <ServerConnection>]
   [-LogicalSwitch] <LogicalSwitch>
   [-Name <String>]
   [-EnablePacketDirect <Boolean>]
   [-RunAsynchronously]
   [-PROTipID <Guid>]
   [-JobVariable <String>]
   [<CommonParameters>]
Set-SCLogicalSwitch
   [-Description <String>]
   [-EnableSriov <Boolean>]
   [-SwitchUplinkMode <SwitchUplinkMode>]
   [-MinimumBandwidthMode <BandwidthMode>]
   [-VMMServer <ServerConnection>]
   [-LogicalSwitch] <LogicalSwitch>
   [-RemoveAllExtensions]
   [-Name <String>]
   [-EnablePacketDirect <Boolean>]
   [-RunAsynchronously]
   [-PROTipID <Guid>]
   [-JobVariable <String>]
   [<CommonParameters>]

Description

Set-SCLogicalSwitch cmdlet'i bir mantıksal anahtarın özelliklerini güncelleştirir.

Örnekler

Örnek 1: Mantıksal anahtar için en düşük bant genişliği modunu değiştirme

PS C:\> Get-SCLogicalSwitch -Name "LogicalSwitch01" | Set-SCLogicalSwitch -MinimumBandwidthMode "Weight"

Bu komut LogicalSwitch01 adlı mantıksal anahtar nesnesini alır ve nesneyi Set-SCLogicalSwitch'e geçirmek için işlem hattı işlecini kullanır ve bu da mantıksal anahtar nesnesinin en düşük bant genişliği modunu Weight olarak değiştirir.

Örnek 2: Mantıksal anahtardan tüm sanal anahtar uzantılarını kaldırma

PS C:\> Get-SCLogicalSwitch -Name "LogicalSwitch01" | Set-SCLogicalSwitch -RemoveAllExtensions

Bu komut LogicalSwitch01 adlı mantıksal anahtar nesnesini alır ve nesneyi Set-SCLogicalSwitch'e geçirmek için işlem hattı işlecini kullanır ve bu da mantıksal anahtar nesnesinden tüm sanal anahtar uzantılarını kaldırır.

Parametreler

-Description

Belirtilen nesne için bir açıklama belirtir.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-EnablePacketDirect

Cmdlet'in anahtarda Doğrudan Paket'i etkinleştirip etkinleştirmediğini belirtir.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-EnableSriov

Tek köklü G/Ç sanallaştırmanın (SR-IOV) etkinleştirilip etkinleştirilmediğini gösterir.

Type:Boolean
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-JobVariable

İş ilerleme durumunun izlendiği ve depolandığı bir değişken belirtir.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-LogicalSwitch

Mantıksal anahtar nesnesini belirtir.

Type:LogicalSwitch
Position:0
Default value:None
Required:True
Accept pipeline input:True
Accept wildcard characters:False

-MinimumBandwidthMode

Mantıksal anahtar için en düşük bant genişliği modunu belirtir. Bu parametrenin kabul edilebilir değerleri şunlardır:

  • Varsayılan
  • Ağırlık
  • Mutlak
  • Hiçbiri
Type:BandwidthMode
Accepted values:Default, Weight, Absolute, None
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Name

Virtual Machine Manager (VMM) nesnesinin adını belirtir.

Type:String
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-PROTipID

Bu eylemi tetikleyen Performans ve Kaynak İyileştirme (PRO) ipucunun kimliğini belirtir. Bu, PRO ipuçlarının denetlenmesini sağlar.

Type:Guid
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-RemoveAllExtensions

Tüm sanal anahtar uzantılarının mantıksal anahtardan kaldırıldığını gösterir.

Type:SwitchParameter
Position:Named
Default value:None
Required:True
Accept pipeline input:False
Accept wildcard characters:False

-RunAsynchronously

Denetimin komut kabuğuna hemen döndürülmesi için işin zaman uyumsuz olarak çalıştığını gösterir.

Type:SwitchParameter
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-SwitchUplinkMode

Anahtar yukarı bağlantı modu nesnesini belirtir.

Type:SwitchUplinkMode
Accepted values:NoTeam, Team, EmbeddedTeam
Position:Named
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-VirtualSwitchExtensions

Sanal anahtar uzantısı nesnelerinin dizisini belirtir.

Sanal anahtar uzantısı nesnesi almak için Get-SCVirtualSwitchExtension cmdlet'ini kullanın.

Type:VirtualSwitchExtension[]
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-VMMServer

BIR VMM sunucu nesnesi belirtir.

Type:ServerConnection
Position:Named
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False