Configuration Manager cmdlet library changes for version 2309
Applies to: Configuration Manager (current branch)
These release notes summarize changes to the Configuration Manager cmdlet library in version 2309.
Note
Configuration Manager current branch version 2111 is the baseline for these changes. For more information, see Configuration Manager cmdlet library changes for version 2111.
New cmdlets
New-CMWindows11EditionUpgrade
Use this cmdlet to create a Windows 11 edition upgrade policy. For more information, see About upgrading windows version in Configuration Manager.
New-CMWindows11EditionUpgrade -Name "NewEditionPolicyByKey" -WindowsEdition Windows11Enterprise -ProductKey "123ab-cd456-789ef-2j3k4-0ghi1"
Set-UpdateServerApplication
Use this cmdlet to add the missing URL 'http://localhost' to your existing server app. For more information, see About creating and deploying applications in Configuration Manager.
SET-UpdateServerApplication -TenantId 1E7C0B63-1DAB-4754-8433-AF8F9CFFCF38
Cmdlet changes
The following changes have been made to existing cmdlets in this version. Changes may be new functionality or bug fixes. Some changes may be breaking. If you use one of the cmdlets or feature areas listed in this section, carefully review the changes to understand how they may affect your use.
Add-CMDistributionPoint
For more information, see Add-CMDistributionPoint.
Non-breaking changes
Two new parameters have been added to the cmdlet
- InitialMPForLookup: It's required (and requires) when providing -PreferredMPEnabled parameter. It expects a string input that represents the different lookup MPs separated by the * symbol. MPs are filtered based on the Site code of the DP, if the MP's site code is different, an error is thrown.
- PreferredMPEnabled: It's a switch parameter. The presence of the parameter indicates that the dynamic MP usage is enabled. PXE has to be enabled on the Distribution Point before using this parameter.
Set-CMDistributionPoint
For more information, see Set-CMDistributionPoint.
Non-breaking changes
Two new parameters have been added to the cmdlet
- InitialMPForLookup: This parameter expects a string that represents the different lookup MPs separated by the symbol'*'. MPs are filtered out based on the Site code of the DP, if the MP's site code is different, an error is thrown.
- PreferredMPEnabled: This parameter is boolean where the $true value for the parameter indicates that the dynamic MP usage is enabled. PXE has to be enabled on the Distribution Point before using this parameter.
Invoke-CMScript
For more information, see Invoke-CMScript.
Non-breaking changes
A new optional parameter, ScheduleTime, has been added to the Invoke-CMScript cmdlet. It specifies the script runtime(UTC).
$ScriptObj = Get-CMScript -ScriptName "test"
Invoke-CMScript -InputObject $ScriptObj -CollectionId "SMSDM003" -ScheduleTime "08/02/2023 07:35:00"
New-CMCloudManagementGateway
For more information, see New-CMCloudManagementGateway.
Non-breaking changes
A new parameter, TenantId, has been added to the New-CMCloudManagementGateway cmdlet.
How to provide feedback or report issues
Many of the fixes and improvements described in this article are a result of your feedback.
To send feedback, use the Configuration Manager console. For more information, see Feedback for PowerShell.