Редагувати

Поділитися через


SMS_TaskSequence_SetVariableAction server WMI class

The SMS_TaskSequence_SetVariableAction WMI class is an SMS Provider server class in Configuration Manager. It represents a task sequence action that sets the value of a task sequence environment variable.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Syntax

Class SMS_TaskSequence_SetVariableAction : SMS_TaskSequence_Action
{
      SMS_TaskSequence_Condition Condition;
      Boolean ContinueOnError;
      String Description;
      Boolean DoNotShowVariableValue;
      Boolean Enabled;
      string HiddenVariableValue;
      String Name;
      String SupportedEnvironment;
      UInt32 Timeout;
      String VariableName;
      String VariableValue;
};

Methods

The SMS_TaskSequence_SetVariableAction class doesn't define any methods.

Properties

Condition

Data type: SMS_TaskSequence_Condition

Access type: Read/Write

Qualifiers: None

For more information, see SMS_TaskSequence_Action server WMI class.

ContinueOnError

Data type: Boolean

Access type: Read/Write

Qualifiers: None

For more information, see SMS_TaskSequence_Action server WMI class.

Description

Data type: String

Access type: Read/Write

Qualifiers: [AllowedLen("0-255")]

For more information, see SMS_TaskSequence_Action server WMI class.

DoNotShowVariableValue

Data type: Boolean

Access type: Read/write

Default value false. This property corresponds to the setting in the task sequence editor, Do not display this value.

Enabled

Data type: Boolean

Access type: Read/Write

Qualifiers: None

For more information, see SMS_TaskSequence_Action server WMI class.

HiddenVariableValue

Data type: String

Access type: Read/write

Hidden value of the task sequence environment variable. The value length must be between 0 and 4,001 characters.

Name

Data type: String

Access type: Read/Write

Qualifiers: [AllowedLen("1-100")]

For more information, see SMS_TaskSequence_Action server WMI class.

SupportedEnvironment

Data type: String

Access type: Read/Write

Qualifiers: [Not_Null:ToInstance]

For more information, see SMS_TaskSequence_Action server WMI class.

Timeout

Data type: UInt32

Access type: Read/Write

Qualifiers: None

For more information, see SMS_TaskSequence_Action server WMI class.

VariableName

Data type: String

Access type: Read/Write

Qualifiers: [CommandLineArg(1), Not_Null, AllowedLen("1-256")]

Name of the task sequence environment variable to set. The name length must be between 1 and 256 characters.

VariableValue

Data type: String

Access type: Read/Write

Qualifiers: [CommandLineArg(2), Not_Null, AllowedLen("0-4001")]

Value of the task sequence environment variable. The value length must be between 0 and 4,001 characters.

Remarks

Class qualifiers for this class include:

[CommandLine("tsenv.exe \\"%1=%2\\""),  

ActionCategory{"General,7,1"},ActionUI{"AdminUI.TaskSequenceEditor.dll", "Microsoft.ConfigurationManagement.AdminConsole.TaskSequenceEditor", "SetSequenceVariableControl", "TaskSequenceOptionControl"}]  

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager class and property qualifiers.

Requirements

Runtime requirements

For more information, see Configuration Manager server runtime requirements.

Development requirements

For more information, see Configuration Manager server development requirements.