IIS WAS Availability

Applies To: Windows Server 2008 R2

The Internet Information Services (IIS) Windows Process Activation Service (WAS) is needed for most Web sites because it supports the World Wide Web Publishing Service (W3SVC), which handles HTTP requests. The WAS Process Manager maps application pools to existing worker processes and spawns new instances of W3SVC to host new application pools as needed. If WAS is not available, most Web sites will not start.

Events

Event ID Source Message

5030

Microsoft-Windows-WAS

Windows Process Activation Service terminated unexpectedly and the system was not configured to restart it. The Windows Process Activation Service has shut down.

5036

Microsoft-Windows-WAS

The configuration manager for Windows Process Activation Service (WAS) did not initialize. The data field contains the error number.

5092

Microsoft-Windows-WAS

The Windows Process Activation Service failed to issue a request for the worker process '%2' of application pool '%1' to supply its performance counters. The data field contains the error number.

5118

Microsoft-Windows-WAS

After recovering from an unexpected termination of the inetinfo process, Windows Process Activation Service (WAS) did not identify records that require deletion from the metadata cache. The data field contains the error number.

5153

Microsoft-Windows-WAS

The Windows Process Activation Service (WAS) encountered an error attempting to look up the built in IIS_IUSRS group. There may be problems in viewing and setting security permissions with the IIS_IUSRS group. This happens if the machine has been joined and promoted to be a Domain Controller in a legacy domain. Please see the online help for more information and solutions to this problem. The data field contains the error number.

5165

Microsoft-Windows-WAS

Windows Process Activation Service (WAS) did not notify protocol %1 to enable request processing. Requests made to this protocol may be rejected. If this error occurred when WAS was starting, the service will not start. To resolve this issue, restart WAS. The data field contains the error number.

5177

Microsoft-Windows-WAS

Windows Process Activation Service (WAS) did not create a relationship between protocol %1 and application %2, which belongs to site %3. The listener adapter for this protocol will not be notified about this application. To resolve this issue, restart WAS. The data field contains the error number.

IIS Windows Process Activation Service (WAS)

Internet Information Services (IIS) 7.5