Sdílet prostřednictvím


Test-WebServicesConnectivity

 

Applies to: Exchange Server 2007 SP1, Exchange Server 2007 SP2, Exchange Server 2007 SP3

The Test-WebServicesConnectivity cmdlet performs basic operations to verify the functionality of Exchange Web Services on a Microsoft Exchange Server 2007 computer that has the Client Access server role installed.

Syntax

Test-WebServicesConnectivity [-ClientAccessServer <ServerIdParameter>] [-AllowUnsecureAccess <SwitchParameter>] [-Confirm [<SwitchParameter>]] [-DomainController <Fqdn>] [-LightMode <SwitchParameter>] [-MailboxCredential <PSCredential>] [-MailboxServer <ServerIdParameter>] [-MonitoringContext <SwitchParameter>] [-ResetTestAccountCredentials <SwitchParameter>] [-Site <AdSiteIdParameter>] [-Timeout <UInt32>] [-TrustAnySSLCertificate <SwitchParameter>] [-UseAutodiscoverForClientAccessServer <SwitchParameter>] [-WhatIf [<SwitchParameter>]]

Detailed Description

The Test-WebServicesConnectivity cmdlet lets you test the functionality of Exchange Web Services. If the test fails, a message is displayed in the Exchange Management Shell.

To run the Test-WebServicesConnectivity cmdlet, the account you use must be delegated the Exchange Administrator role and local Administrators group for the target server.

For more information about permissions, delegating roles, and the rights that are required to administer Exchange 2007, see Permission Considerations.

Parameters

Parameter Required Type Description

AllowUnsecureAccess

Optional

System.Management.Automation.SwitchParameter

This parameter enables the Test-WebServicesConnectivity cmdlet to continue to run over an unsecured channel that does not require Secure Sockets Layer (SSL).

ClientAccessServer

Optional

Microsoft.Exchange.Configuration.Tasks.ServerIdParameter

This parameter specifies the Client Access server to use when the Test-WebServicesConnectivity cmdlet is run.

Confirm

Optional

System.Management.Automation.SwitchParameter

This parameter causes the command to pause processing and requires that you acknowledge what the command will do before processing continues. You do not have to specify a value with the Confirm parameter.

DomainController

Optional

Microsoft.Exchange.Data.Fqdn

The DomainController parameter specifies the domain controller to use to write this configuration change to the Active Directory directory service. Use the fully qualified domain name (FQDN) of the domain controller that you want to use.

LightMode

Optional

System.Management.Automation.SwitchParameter

This parameter is not implemented for the Test-PopConnectivity diagnostic cmdlet. Using this parameter does not change the behavior of the cmdlet.

Note   This cmdlet is implemented for other Exchange 2007 diagnostic cmdlets. Specifically, it is used when you want to run a less intensive version of a cmdlet.

MailboxCredential

Optional

System.Management.Automation.PSCredential

This parameter specifies the mailbox to use when the Test-WebServicesConnectivity cmdlet is run.

MailboxServer

Optional

Microsoft.Exchange.Configuration.Tasks.ServerIdParameter

This parameter specifies the identity of the Exchange 2007 Mailbox server on which the test will be run.

MonitoringContext

Optional

System.Management.Automation.SwitchParameter

This parameter specifies whether the test result is passed to Microsoft Operations Manager (MOM). If this parameter is set to $true, the test result is passed to MOM. If this parameter is set to $false, the test result appears only in the command line.

ResetTestAccountCredentials

Optional

System.Management.Automation.SwitchParameter

The ResetTestAccountCredentials parameter resets the password for the test account used to perform this command. The password for the test account is typically reset every seven days if you're using Microsoft System Center Operations Manager to manage your Exchange environment. Use of this flag forces a password reset at any time if it's required for security reasons.

Site

Optional

Microsoft.Exchange.Configuration.Tasks.AdSiteIdParameter

The Site parameter is used to specify the Active Directory site.

Timeout

Optional

System.UInt32

The Timeout parameter specifies the amount of time, in seconds, to wait for the test operation to finish. The default value for the Timeout parameter is 300 seconds. You must specify a time-out value greater than 0 seconds. We recommend that you always configure this parameter with a value of 5 seconds or more.

TrustAnySSLCertificate

Optional

System.Management.Automation.SwitchParameter

This parameter allows the test to use any SSL certificate that is available.

UseAutodiscoverForClientAccessServer

Optional

System.Management.Automation.SwitchParameter

This parameter specifies whether the test should use the Autodiscover service to locate the Client Access server.

WhatIf

Optional

System.Management.Automation.SwitchParameter

This parameter instructs the command to simulate the actions that it would take on the object. By using the WhatIf parameter, you can view what changes would occur without having to apply any of those changes. You do not have to specify a value with the WhatIf parameter.

Input Types

Return Types

Errors

Error Description

 

 

Exceptions

Exceptions Description

 

 

Example

The following code example tests the Exchange Web Services on the local Client Access server and allows the test to use an unsecured connection that does not require SSL. A default test account will be used.

Test-WebServicesConnectivity -AllowUnsecureAccess