Upravit

Sdílet prostřednictvím


Application Configuration Files

An application configuration file is an XML file used to control assembly binding. It can redirect an application from using one version of a side-by-side assembly to another version of the same assembly. This is called per-application configuration. An application configuration file applies only to a specific application manifest and dependent assemblies. Isolated components compiled with an embedded ISOLATIONAWARE_MANIFEST_RESOURCE_ID manifest require a separate application configuration file. Manifests managed with CreateActCtx require a separate application configuration file.

The redirection specified by an application configuration file can override the assembly versions specified by application manifests and publisher configuration files. For example, if a publisher configuration file specifies that all references to an assembly be redirected from version 1.0.0.0 to 1.1.0.0, an application configuration file can be used to redirect a particular application to use version 1.0.0.0. An application configuration file applies only to the specified application manifest and dependent assemblies.

For a complete listing of the XML schema, see Application Configuration File Schema.

Application configuration files have the elements and attributes shown in the following table.

Element Attributes Required
configuration Yes
windows Yes
publisherPolicy Yes
apply Yes
runtime No
assemblyBinding Yes
probing No
privatePath Yes
dependency No
dependentAssembly Yes
assemblyIdentity Yes
type Yes
name Yes
language No
processorArchitecture Yes
version Yes
publicKeyToken No
bindingRedirect Yes
oldVersion Yes
newVersion Yes

File Location

Application configuration files must be installed in the same location as the application's application manifest.

File Name Syntax

The name of an application configuration file is the name of the application executable followed by .config.

For example, an application configuration file that refers to Example.exe or Example.dll would use the file name syntax shown in the following example. You can omit the field for <resource ID> if installing the configuration file as a separate file or if the resource ID is 1.

example.exe.<resource ID>.config

example.dll.<resource ID>.config

Elements

Names of elements and attributes are case-sensitive. The values of elements and attributes are all case-insensitive, except for the value of the type attribute.

configuration

A container element for the windows and runtime elements of an application configuration file. Required.

windows

Includes the parts of the application configuration file that apply to the redirection of Win32 assemblies.

Note

The author of an application should not include a configuration file with a windows subelement as part of their application. This may be permitted if the configuration file's only purpose is to enable the privatePath functionality of a probing element. The probing element is unavailable on systems earlier than Windows Server 2008 R2 and Windows 7.

publisherPolicy

Specifies whether to apply publisher policy.

This element has the attributes shown in the following table.

Attribute Description
apply A value of "yes" applies the publisher policy. This is the default setting. The value "no" does not apply the publisher policy.

runtime

Includes the parts of the application configuration file that apply to redirection of .Net assemblies.

assemblyBinding

Includes the redirection information for the application and the assembly affected by this application configuration file. The first subelement of assemblyBinding must be an assemblyIdentity that identifies the application.

Starting with Windows Server 2008 R2 and Windows 7 an assemblyBinding element can include a probing subelement.

probing

An optional subelement of an assemblyBinding element that extends the search for assemblies into additional directories. The additional directories are not required to be subdirectories of the directory of the assembly.

Note

This element is unavailable on systems earlier than Windows Server 2008 R2 and Windows 7 and can only be used within a windows element.

This element has the attributes shown in the following table.

Attribute Description
privatePath Specifies the relative paths of subdirectories of the application's base directory that might contain assemblies. A maximum of nine subdirectory paths can be specified. Delimit each subdirectory path with a semicolon.

You can use the double-dots special specifier in a path to denote the parent directory of the current directory. No more than two levels above the current directory can be specified using double-dots. Do not use triple-dots. For example, an application using the following probing element checks additional directories for an assembly.

<probing privatePath="bin;..\bin2\subbin;bin3"/>

dependency

A container element for at least one dependentAssembly. Every dependentAssembly can be inside exactly one dependency. This element has no attributes. Optional.

dependentAssembly

The first subelement must be an assemblyIdentity element that identifies the side-by-side assembly being redirected by the application configuration file. A dependentAssembly has no attributes.

assemblyIdentity

As the first subelement of an assemblyBinding element, assemblyIdentity describes and uniquely identifies an application. The application configuration file redirects the binding of this application to side-by-side assemblies. For example, the following assemblyIdentity indicates that the application configuration file affects the binding of the application mysampleApp to side-by-side assemblies. The assemblies being redirected would be identified in a dependentAssembly.

<assemblyIdentity processorArchitecture="X86" name="Microsoft.Windows.mysampleApp" type="win32" version="1.0.0.0"/>

As the first subelement of a dependentAssembly element, assemblyIdentity describes a side-by-side assembly on which the application depends. The application configuration file reconfigures the identity of this required assembly. For example, the following assemblyIdentity and bindingRedirect reconfigures a dependency on Microsoft.Windows.SampleAssembly from version 2.0.0.0 to version 2.1.0.0.

<dependency>
      <dependentAssembly>
         <assemblyIdentity type="win32"
          name="Microsoft.Windows.SampleAssembly"
          processorArchitecture="x86"
          publicKeyToken="0000000000000000"/>
         <bindingRedirect oldVersion="2.0.0.0" newVersion="2.1.0.0"/>
      </dependentAssembly>
</dependency>

Note that every assemblyIdentity included in a dependentAssembly must exactly match the assemblyIdentity in the assembly's own assembly manifest.

The assemblyIdentity element has the following attributes. It has no subelements.

Attribute Description
type The value must be win32 (lower case). Required.
name The name attribute identifies the application being affected by the application configuration file or the assembly being redirected. Use the following format for the name: Organization.Division.Name. Required. For example: Microsoft.Windows.MysampleApp or Microsoft.Windows.MysampleAsm.
language Identifies the language. Optional. For an assemblyIdentity referring to an assembly, if the assembly is language-specific, specify the DHTML language code. If the assembly is for worldwide use (language neutral) set the value as "*".
processorArchitecture Specifies the processor running the application.
version Specifies the version of the application or assembly. Use four-part version syntax: mmmm.nnnn.oooo.pppp. Required.
publicKeyToken For an assemblyIdentity referring to an assembly, a 16-character hexadecimal string representing the last 8 bytes of the SHA-1 hash of the public key under which the assembly is signed. The public key used to sign the catalog must be 2048 bits or greater. Required for all shared side-by-side assemblies.

bindingRedirect

The bindingRedirect element contains redirection information for the binding of the assembly. Each bindingRedirect must be included in exactly one dependentAssembly. The four-part version syntax of the new version and the old version must specify the same major and minor versions.

This element has the attributes shown in the following table.

Attribute Description
oldVersion Specifies the assembly version being overridden and redirected. Use the four-part version syntax nnnnn.nnnnn.nnnnn.nnnnn. Specify a range of versions by a dash without spaces. For example, 2.14.3.0 or 2.14.3.0 2.16.0.0. Required.
newVersion Specifies the replacement assembly version. Use four-part version syntax nnnnn.nnnnn.nnnnn.nnnnn.

Remarks

Application configuration files do not specify files.

Example

<bindingRedirect oldVersion="1.0.0.0" newVersion="1.0.10.0"/>
<bindingRedirect oldVersion="1.0.50.2011-1.0.60.65535" newVersion="1.0.70.0"/>