Upravit

Sdílet prostřednictvím


LocalComputer collection

Contains a single object that corresponds to the computer whose catalog you are accessing. This object holds computer level settings information. If you call the Connect method on an object created from the COMAdminCatalog class, the object in the LocalComputer collection contains information about the remote computer whose catalog you are accessing.

This collection does not support the Add and Remove methods of the COMAdminCatalogCollection object.

Members

The LocalComputer collection inherits from the IUnknown interface but does not have additional members.

You can navigate from this collection to any of the following collections:

You can navigate to this collection from the following collections:

Properties

The following properties are supported by the COMAdminCatalogObject object within the collection:

ApplicationProxyRSN

Entry Value
Description Remote server name used by application proxies by default.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

CISEnabled

Entry Value
Description Indicates whether COM Internet Services is enabled.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

DCOMEnabled

Entry Value
Description Set to True to enable DCOM on the computer.
Access ReadWrite
Type Bool
Default True
Minimum system Windows 2000

 

DefaultAuthenticationLevel

Entry Value
Description Authentication level used by applications that have Authentication set to Default. Values correspond to the Remote Procedure Call (RPC) authentication settings.
Access ReadWrite
Type Long Possible values:COMAdminAuthenticationDefault (0)COMAdminAuthenticationNone (1) COMAdminAuthenticationConnect (2)COMAdminAuthenticationCall (3)COMAdminAuthenticationPacket (4)COMAdminAuthenticationIntegrity (5)COMAdminAuthenticationPrivacy (6)
Default COMAdminAuthenticationConnect (2)
Minimum system Windows 2000

 

Note

COMAdminAuthenticationDefault is mapped to COMAdminAuthenticationConnect when COM calls CoInitializeSecurity. It is recommended that you use the constants in the enumeration and not the numeric values.

 

DefaultImpersonationLevel

Entry Value
Description Impersonation level to allow if one is not set.
Access ReadWrite
Type Long Possible values:COMAdminImpersonationAnonymous (1)COMAdminImpersonationIdentify (2)COMAdminImpersonationImpersonate (3)COMAdminImpersonationDelegate (4)
Default COMAdminImpersonationIdentify (2)
Minimum system Windows 2000

 

Note

It is recommended that you use the constants in the enumeration, and not the numeric values.

 

DefaultToInternetPorts

Entry Value
Description Determines whether the default type of port provided should be Internet (True) or intranet (False).
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

Description

Entry Value
Description A description of the computer.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

DSPartitionLookupEnabled

Entry Value
Description Indicates whether the user of the partition mappings is checked into the domain store.
Access ReadWrite
Type Bool
Default True
Minimum system Windows Server 2003

 

InternetPortsListed

Entry Value
Description Determines whether the ports listed in the Ports property are to be used for Internet (True) or for intranet (False).
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

IsRouter

Entry Value
Description Set to True if the computer is a router for the component load balancing (CLB) service. This property can be set to True only if the component load balancing service is currently installed on the computer; otherwise, it errors with COMADMIN_E_REQUIRES_DIFFERENT_PLATFORM.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

If this property is set to True, the CLB server is configured and starts at startup. The server is added to the ApplicationCluster collection if it is not already present.

LoadBalancingCLSID

Entry Value
Description The CLSID of the object to balance.
Access ReadWrite
Type String
Default NULL
Minimum system Windows XP

 

LocalPartitionLookupEnabled

Entry Value
Description Indicates whether the user of the partition mappings is checked into the local store.
Access ReadWrite
Type Bool
Default True
Minimum system Windows Server 2003

 

Name

Entry Value
Description The name of the computer. Extra spaces at the beginning and end of the string are stripped out. This property is returned when the Key or Name property method is called on an object of this collection.
Access WriteOnce
Type String
Default "My Computer"
Minimum system Windows 2000

 

OperatingSystem

Entry Value
Description The operating system installed on the local computer.
Access ReadWrite
Type Long Possible values:COMAdminOSNotInitialized (0)COMAdminOSWindows3_1(1)COMAdminOSWindows9x (2)COMAdminOSWindows2000 (3)COMAdminOSWindows2000AdvancedServer (4)COMAdminOSWindows2000Unknown (5)COMAdminOSUnknown (6)COMAdminOSWindowsXPPersonal (11)COMAdminOSWindowsXPProfessional (12)COMAdminOSWindowsNETStandardServer (13)COMAdminOSWindowsNETEnterpriseServer (14)COMAdminOSWindowsNETDatacenterServer (15)COMAdminOSWindowsNETWebServer (16)
Default COMAdminOSNotInitialized (0)
Minimum system Windows 2000

 

PartitionsEnabled

Entry Value
Description Indicates whether COM+ partitions can be used on the local computer. If this property is False, any attempt to use COM+ partitions results in an error.
Access ReadWrite
Type Bool
Default False
Minimum system Windows Server 2003

 

Ports

Entry Value
Description A string describing ports that are for either Internet or intranet use, depending on the InternetPortsListed property; for example, "500-599: 600-800".
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

ResourcePoolingEnabled

Entry Value
Description Enables use of resource dispensers.
Access ReadWrite
Type Bool
Default True
Minimum system Windows 2000

 

RPCProxyEnabled

Entry Value
Description Controls whether the RPC IIS proxy is enabled. The RPC IIS proxy is used in conjunction with IIS to forward calls to the RPC mechanism from IIS and is one of the core pieces of COM Internet Services, which is enabled by setting CISEnabled to True. For more information on RPCProxyEnabled, see HTTP RPC Security.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

SecureReferencesEnabled

Entry Value
Description Enforces in DCOM computers that cross-process calls to IUnknown::AddRef and IUnknown::Release methods are secured.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

SecurityTrackingEnabled

Entry Value
Description Set to True if security tracking is enabled on objects.
Access ReadWrite
Type Bool
Default True
Minimum system Windows 2000

 

SRPActivateAsActivatorChecks

Entry Value
Description Determines how the software restriction policy (SRP) handles activate-as-activator connections. If set to True, the SRP trust level that is configured for the server object is compared with the SRP trust level of the client object and the higher (more stringent) trust level is used to run the server object. If set to False, the server object runs with the SRP trust level of the client object, regardless of the SRP trust level with which the server is configured.
Access ReadWrite
Type Bool
Default True
Minimum system Windows XP

 

SRPRunningObjectChecks

Entry Value
Description Determines how the software restriction policy (SRP) handles attempted connections to existing processes. If set to False, attempts to connect to running objects are not checked for appropriate SRP trust levels. If set to True, the running object must have an equal or higher (more stringent) SRP trust level than the client object. For example, a client object with an Unrestricted SRP trust level cannot connect to a running object with a Disallowed SRP trust level.
Access ReadWrite
Type Bool
Default True
Minimum system Windows XP

 

TransactionTimeout

Entry Value
Description Should be set to a sufficient value in seconds if you are doing numerous operations within a transaction. The default time-out period is 60 seconds, and the maximum time-out period is 3600 seconds (1 hour). Setting this property to 0 disables transaction time-outs. This property can be overridden by individual components by using the ComponentTransactionTimeout property of the Components collection.
Access ReadWrite
Type Long (0-3600)
Default 60
Minimum system Windows 2000

 

Example

The following Microsoft Visual Basic example demonstrates how to connect to a remote computer and get its SecurityTrackingEnabled property by using the LocalComputer collection of the remote computer. To use this example, add the COM+ Admin Type Library as a reference to your Visual Basic project.

Function RemoteComputerConnect(strComputer As String _
) As Boolean  ' Return False if any errors occur.
    
    RemoteComputerConnect = False   ' Initialize the function.
    On Error GoTo My_Error_Handler  ' Initialize error handling.

    Dim boolSTE As Boolean
    Dim objCatalog As COMAdminCatalog
    Dim objRemoteRootColl As COMAdminCatalogCollection
    Dim objRemoteComputerColl As COMAdminCatalogCollection
    Dim objRemoteComputerItem As COMAdminCatalogObject
    
    Set objCatalog = CreateObject("COMAdmin.COMAdminCatalog")
    Set objRemoteRootColl = objCatalog.Connect(strComputer)
    Set objRemoteComputerColl = objRemoteRootColl.GetCollection( _
      "LocalComputer", objRemoteRootColl.Name)
    objRemoteComputerColl.Populate
    Set objRemoteComputerItem = objRemoteComputerColl.Item(0)
    boolSTE = objRemoteComputerItem.Value("SecurityTrackingEnabled")
    If boolSTE Then
        MsgBox "Security Tracking is enabled on " & strComputer
    Else
        MsgBox "Security Tracking is NOT enabled on " & strComputer
    End If

    Set objRemoteComputerItem = Nothing
    Set objRemoteComputerColl = Nothing
    Set objRemoteRootColl = Nothing
    Set objCatalog = Nothing
    RemoteComputerConnect = True  ' Successful end to procedure
    Exit Function

My_Error_Handler:  ' Replace with specific error handling.
    MsgBox "Error # " & Err.Number & " (Hex: " & Hex(Err.Number) _
      & ")" & vbNewLine & Err.Description
    Set objRemoteComputerItem = Nothing
    Set objRemoteComputerColl = Nothing
    Set objRemoteRootColl = Nothing
    Set objCatalog = Nothing
End Function


To use the function, provide a string value for the name of the remote computer. The following Visual Basic code shows how to connect to the computer named "RemoteComputerName".

Sub Main()
    If Not RemoteComputerConnect("RemoteComputerName") Then
        MsgBox "RemoteComputerConnect failed."
    End If
End Sub

See also

COM+ Administration Collections