InjectNtmsCleaner Function
[Removable Storage Manager is no longer available as of Windows 7 and Windows Server 2008 R2.]
The InjectNtmsCleaner function allows a cleaner cartridge to be inserted into the specified library unit.
Syntax
DWORD InjectNtmsCleaner(
__in HANDLE hSession,
__in LPNTMS_GUID lpLibrary,
__inout LPNTMS_GUID lpInjectOperation,
__out WORD dwNumberOfCleansLeft,
__in DWORD dwAction
);
Parameters
hSession [in]
Handle to the session returned by the OpenNtmsSession function.lpLibrary [in]
Unique identifier of a library object.lpInjectOperation [in, out]
GUID of the insert process library operation. If dwAction is NTMS_INJECT_START, this parameter receives the GUID for the operation. If dwAction is NTMS_INJECT_STOP, this parameter must be set to the GUID for the operation to be stopped.dwNumberOfCleansLeft [out]
Number of cleaning cycles left on the inserted cleaning cartridge.dwAction [in]
This parameter can be one of the following values.Value Meaning NTMS_INJECT_START Start the insertion with either the NTMS_IEPORT or the NTMS_IEDOOR object. A single cleaner cartridge should be inserted. If the NTMS_IEDOOR object is used, no inventory will be performed on the library.
NTMS_INJECT_STOP Terminates the insertion prior to the time-out event lapsing. (For libraries with ports only.)
Return Value
This function returns one of the following values.
Value | Meaning |
---|---|
ERROR_ACCESS_DENIED | Access to at least one RSM object is denied. |
ERROR_DEVICE_NOT_AVAILABLE | The library is not currently connected. |
ERROR_INVALID_HANDLE | The value specified in the hSession parameter is not valid. |
ERROR_INVALID_LIBRARY | Unable to retrieve the library definition from the database. |
ERROR_LIBRARY_OFFLINE | The library must be online for a cleaner cartridge to be inserted. |
ERROR_NO_SLOT_SET | This library has no slot reserved as a cleaner slot. |
ERROR_SLOT_FULL | A cleaner slot is reserved but already has a cleaner cartridge. The cleaner cartridge must be ejected first, using the EjectNtmsCleaner function. |
ERROR_SLOT_NOT_PRESENT | A cleaner slot is reserved but the slot specified is currently not installed in the library. This error occurs if at least one magazine is missing from the library. |
ERROR_SUCCESS | The function was successful. |
Remarks
This function returns to the application as soon as the insert request is queued.
To use the InjectNtmsCleaner function, the number of cleaning cycles that remain on the cleaner cartridge must be specified so that RSM can keep track of it.
If an NTMS_IEPORT object is available, the NTMS_IEPORT object directs the cartridge to the currently reserved cleaner slot.
If there is no NTMS_IEPORT object, a door access is performed. In this case, the operator is directed to place the media into the reserved slot.
Requirements
Minimum supported client |
Windows 2000 Professional |
Minimum supported server |
Windows 2000 Server |
End of client support |
Windows Vista |
End of server support |
Windows Server 2008 |
Header |
Ntmsapi.h |
Library |
Ntmsapi.lib |
DLL |
Ntmsapi.dll |
See Also
Send comments about this topic to Microsoft
Build date: 6/9/2011