Duplicate detection

If an application fails due to a fatal error immediately after sending a message, and the restarted application instance erroneously believes that the prior message delivery didn't occur, a subsequent send causes the same message to appear in the system twice.

It's also possible for an error at the client or network level to occur a moment earlier, and for a sent message to be committed into the queue, with the acknowledgment not successfully returned to the client. This scenario leaves the client in doubt about the outcome of the send operation.

Duplicate detection takes the doubt out of these situations by enabling the sender resend the same message, and the queue or topic discards any duplicate copies.

Note

The basic tier of Service Bus doesn't support duplicate detection. The standard and premium tiers support duplicate detection. For differences between these tiers, see Service Bus pricing.

How it works

Enabling duplicate detection helps keep track of the application-controlled MessageId of all messages sent into a queue or topic during a specified time window. If any new message is sent with MessageId that was logged during the time window, the message is reported as accepted (the send operation succeeds), but the newly sent message is instantly ignored and dropped. No other parts of the message other than the MessageId are considered.

Application control of the identifier is essential, because only that allows the application to tie the MessageId to a business process context from which it can be predictably reconstructed when a failure occurs.

For a business process in which multiple messages are sent in the course of handling some application context, the MessageId can be a composite of the application-level context identifier, such as a purchase order number, and the subject of the message, for example, 12345.2017/payment.

The MessageId can always be some GUID, but anchoring the identifier to the business process yields predictable repeatability, which is desired for using the duplicate detection feature effectively.

Important

  • When partitioning is enabled, MessageId+PartitionKey is used to determine uniqueness. When sessions are enabled, partition key and session ID must be the same.
  • When partitioning is disabled (default), only MessageId is used to determine uniqueness.
  • For information about SessionId, PartitionKey, and MessageId, see Use of partition keys.
  • When using partitioning and sending batches of messages, you should ensure that they do not contain any partition identifying properties. Since deduplication relies on explicitly setting message IDs to determine uniqueness, it is not recommended to use deduplication and batching together with partitioning.

Note

Scheduled messages are included in duplicate detection. Therefore, if you send a scheduled message and then send a duplicate non-scheduled message, the non-scheduled message gets dropped. Similarly, if you send a non-scheduled message and then a duplicate scheduled message, the scheduled message is dropped.

Duplicate detection window size

Apart from just enabling duplicate detection, you can also configure the size of the duplicate detection history time window during which message IDs are retained. This value defaults to 10 minutes for queues and topics, with a minimum value of 20 seconds to maximum value of 7 days.

Enabling duplicate detection and the size of the window directly impact the queue (and topic) throughput, since all recorded message IDs must be matched against the newly submitted message identifier.

Keeping the window small means that fewer message IDs must be retained and matched, and throughput is impacted less. For high throughput entities that require duplicate detection, you should keep the window as small as possible.

Next steps

You can enable duplicate message detection using Azure portal, PowerShell, CLI, Resource Manager template, .NET, Java, Python, and JavaScript. For more information, see Enable duplicate message detection.

In scenarios where client code is unable to resubmit a message with the same MessageId as before, it's important to design messages that can be safely reprocessed. This blog post about idempotence describes various techniques for how to do that.

Try the samples in the language of your choice to explore Azure Service Bus features.

See samples for the older .NET and Java client libraries here:

On 30 September 2026, we'll retire the Azure Service Bus SDK libraries WindowsAzure.ServiceBus, Microsoft.Azure.ServiceBus, and com.microsoft.azure.servicebus, which don't conform to Azure SDK guidelines. We'll also end support of the SBMP protocol, so you'll no longer be able to use this protocol after 30 September 2026. Migrate to the latest Azure SDK libraries, which offer critical security updates and improved capabilities, before that date.