Iot.Device.Pn532.RfConfiguration Namespace
Important
Some information relates to prerelease product that may be substantially modified before it’s released. Microsoft makes no warranties, express or implied, with respect to the information provided here.
Classes
Analog106kbpsTypeAMode |
This CfgItem is used to choose the analog settings that the PN532 will use for the baudrate 106kbps type A. When using this command, the host controller has to provide 11 values (ConfigurationData[]) for the following internal registers Actually, there is only one CIU_Demod register which defines a setting used by the reader in reception only.But depending on the RF condition, two different settings can be used for this register: • CIU_Demod when own RF is On defines a setting when its RF field is on during a reception i.e.initiator passive mode, • CIU_Demod when own RF is Off defines a setting when its RF field is off during a reception i.e.initiator active mode. CIU = Contactless Interface Unit Please refer to https://www.nxp.com/docs/en/nxp/data-sheets/PN532_C1.pdf page 144 |
Analog212_424_848kbpsMode |
This CfgItem is used to choose the analog settings that the PN532 will use for the baudrates 212/424/848 kbps with ISO/IEC14443-4 cards. When using this command, the host controller has to provide 9 values (ConfigurationData[]) for the following internal registers: Except for these three specific registers (CIU_RxThreshold, CIU_ModWidth and CIU_MifNFC), the 8 remaining analog registers are the same as the previous CfgItem 0x0A. CIU = Contactless Interface Unit Please refer to https://www.nxp.com/docs/en/nxp/data-sheets/PN532_C1.pdf page 144 |
Analog212_424kbpsMode |
This CfgItem is used to choose the analog settings that the PN532 will use for the baudrates 212/424kbps. When using this command, the host controller has to provide 8 values (ConfigurationData[]) for the following internal registers Actually, there is only one CIU_Demod register which defines a setting used by the reader in reception only.But depending on the RF condition, two different settings can be used for this register: • CIU_Demod when own RF is On defines a setting when its RF field is on during a reception i.e.initiator passive mode, • CIU_Demod when own RF is Off defines a setting when its RF field is off during a reception i.e.initiator active mode. CIU = Contactless Interface Unit Please refer to https://www.nxp.com/docs/en/nxp/data-sheets/PN532_C1.pdf page 144 |
AnalogSettingsTypeBMode |
This CfgItem is used to choose the analog settings that the PN532 will use for the type B when configured as PCD. When using this command, the host controller has to provide 3 new values (ConfigurationData[]) for the following internal registers: Except for these two specific settings, the 8 remaining analog settings are the same as the CfgItem 106 kbps type A. CIU = Contactless Interface Unit Please refer to https://www.nxp.com/docs/en/nxp/data-sheets/PN532_C1.pdf page 144 |
MaxRetriesMode |
The parameters MxRtyATR, MxRtyPSL and MxRtyPassiveActivation define the number of retries that the PN532 will use in case of the following processes |
VariousTimingsMode |
The radio frequency timing modes |
Enums
RfFieldMode |
Radio frequency field modes |
RfTimeout |
Radio frequency timeouts |