WebPart.AllowHide Property
Definition
Important
Some information relates to prerelease product that may be substantially modified before it’s released. Microsoft makes no warranties, express or implied, with respect to the information provided here.
Gets or sets a value indicating whether end users are allowed to hide a WebPart control.
public:
virtual property bool AllowHide { bool get(); void set(bool value); };
[System.Web.UI.Themeable(false)]
[System.Web.UI.WebControls.WebParts.Personalizable(System.Web.UI.WebControls.WebParts.PersonalizationScope.Shared)]
public virtual bool AllowHide { get; set; }
[<System.Web.UI.Themeable(false)>]
[<System.Web.UI.WebControls.WebParts.Personalizable(System.Web.UI.WebControls.WebParts.PersonalizationScope.Shared)>]
member this.AllowHide : bool with get, set
Public Overridable Property AllowHide As Boolean
Property Value
true
if the WebPart control can be hidden; otherwise, false
. The default value is true
.
- Attributes
Examples
The following code example demonstrates how to change the default setting of the AllowHide property for a custom Web Parts control, so that the custom control cannot be hidden by a user. This example assumes the use of a custom WebPart control, TextDisplayWebPart
, which is found in the Example section of the WebPart class overview.
The code example also uses a custom user control that enables users to change display modes on a Web Parts page. The user control is referenced by means of a Register
directive near the top of the Web page that hosts the user control. For a detailed description of how to create this user control and work with display modes, see Walkthrough: Developing and Using a Custom Web Server Control.
<%@ control language="C#" classname="DisplayModeMenuCS"%>
<script runat="server">
// Use a field to reference the current WebPartManager.
WebPartManager _manager;
void Page_Init(object sender, EventArgs e)
{
Page.InitComplete += new EventHandler(InitComplete);
}
void InitComplete(object sender, System.EventArgs e)
{
_manager = WebPartManager.GetCurrentWebPartManager(Page);
String browseModeName = WebPartManager.BrowseDisplayMode.Name;
// Fill the dropdown with the names of supported display modes.
foreach (WebPartDisplayMode mode in _manager.SupportedDisplayModes)
{
String modeName = mode.Name;
// Make sure a mode is enabled before adding it.
if (mode.IsEnabled(_manager))
{
ListItem item = new ListItem(modeName, modeName);
DisplayModeDropdown.Items.Add(item);
}
}
// If shared scope is allowed for this user, display the scope-switching
// UI and select the appropriate radio button for the current user scope.
if (_manager.Personalization.CanEnterSharedScope)
{
Panel2.Visible = true;
if (_manager.Personalization.Scope == PersonalizationScope.User)
RadioButton1.Checked = true;
else
RadioButton2.Checked = true;
}
}
// Change the page to the selected display mode.
void DisplayModeDropdown_SelectedIndexChanged(object sender, EventArgs e)
{
String selectedMode = DisplayModeDropdown.SelectedValue;
WebPartDisplayMode mode = _manager.SupportedDisplayModes[selectedMode];
if (mode != null)
_manager.DisplayMode = mode;
}
// Set the selected item equal to the current display mode.
void Page_PreRender(object sender, EventArgs e)
{
ListItemCollection items = DisplayModeDropdown.Items;
int selectedIndex =
items.IndexOf(items.FindByText(_manager.DisplayMode.Name));
DisplayModeDropdown.SelectedIndex = selectedIndex;
}
// Reset all of a user's personalization data for the page.
protected void LinkButton1_Click(object sender, EventArgs e)
{
_manager.Personalization.ResetPersonalizationState();
}
// If not in User personalization scope, toggle into it.
protected void RadioButton1_CheckedChanged(object sender, EventArgs e)
{
if (_manager.Personalization.Scope == PersonalizationScope.Shared)
_manager.Personalization.ToggleScope();
}
// If not in Shared scope, and if user is allowed, toggle the scope.
protected void RadioButton2_CheckedChanged(object sender, EventArgs e)
{
if (_manager.Personalization.CanEnterSharedScope &&
_manager.Personalization.Scope == PersonalizationScope.User)
_manager.Personalization.ToggleScope();
}
</script>
<div>
<asp:Panel ID="Panel1" runat="server"
Borderwidth="1"
Width="230"
BackColor="lightgray"
Font-Names="Verdana, Arial, Sans Serif" >
<asp:Label ID="Label1" runat="server"
Text=" Display Mode"
Font-Bold="true"
Font-Size="8"
Width="120"
AssociatedControlID="DisplayModeDropdown"/>
<asp:DropDownList ID="DisplayModeDropdown" runat="server"
AutoPostBack="true"
Width="120"
OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
<asp:LinkButton ID="LinkButton1" runat="server"
Text="Reset User State"
ToolTip="Reset the current user's personalization data for the page."
Font-Size="8"
OnClick="LinkButton1_Click" />
<asp:Panel ID="Panel2" runat="server"
GroupingText="Personalization Scope"
Font-Bold="true"
Font-Size="8"
Visible="false" >
<asp:RadioButton ID="RadioButton1" runat="server"
Text="User"
AutoPostBack="true"
GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
<asp:RadioButton ID="RadioButton2" runat="server"
Text="Shared"
AutoPostBack="true"
GroupName="Scope"
OnCheckedChanged="RadioButton2_CheckedChanged" />
</asp:Panel>
</asp:Panel>
</div>
<%@ control language="vb" classname="DisplayModeMenuVB"%>
<script runat="server">
' Use a field to reference the current WebPartManager.
Dim _manager As WebPartManager
Sub Page_Init(ByVal sender As Object, ByVal e As EventArgs)
AddHandler Page.InitComplete, AddressOf InitComplete
End Sub
Sub InitComplete(ByVal sender As Object, ByVal e As System.EventArgs)
_manager = WebPartManager.GetCurrentWebPartManager(Page)
Dim browseModeName As String = WebPartManager.BrowseDisplayMode.Name
' Fill the dropdown with the names of supported display modes.
Dim mode As WebPartDisplayMode
For Each mode In _manager.SupportedDisplayModes
Dim modeName As String = mode.Name
' Make sure a mode is enabled before adding it.
If mode.IsEnabled(_manager) Then
Dim item As New ListItem(modeName, modeName)
DisplayModeDropdown.Items.Add(item)
End If
Next mode
' If shared scope is allowed for this user, display the scope-switching
' UI and select the appropriate radio button for the current user scope.
If _manager.Personalization.CanEnterSharedScope Then
Panel2.Visible = True
If _manager.Personalization.Scope = PersonalizationScope.User Then
RadioButton1.Checked = True
Else
RadioButton2.Checked = True
End If
End If
End Sub
' Change the page to the selected display mode.
Sub DisplayModeDropdown_SelectedIndexChanged(ByVal sender As Object, _
ByVal e As EventArgs)
Dim selectedMode As String = DisplayModeDropdown.SelectedValue
Dim mode As WebPartDisplayMode = _
_manager.SupportedDisplayModes(selectedMode)
If Not (mode Is Nothing) Then
_manager.DisplayMode = mode
End If
End Sub
' Set the selected item equal to the current display mode.
Sub Page_PreRender(ByVal sender As Object, ByVal e As EventArgs)
Dim items As ListItemCollection = DisplayModeDropdown.Items
Dim selectedIndex As Integer = _
items.IndexOf(items.FindByText(_manager.DisplayMode.Name))
DisplayModeDropdown.SelectedIndex = selectedIndex
End Sub
' Reset all of a user's personalization data for the page.
Protected Sub LinkButton1_Click(ByVal sender As Object, _
ByVal e As EventArgs)
_manager.Personalization.ResetPersonalizationState()
End Sub
' If not in User personalization scope, toggle into it.
Protected Sub RadioButton1_CheckedChanged(ByVal sender As Object, _
ByVal e As EventArgs)
If _manager.Personalization.Scope = PersonalizationScope.Shared Then
_manager.Personalization.ToggleScope()
End If
End Sub
' If not in Shared scope, and if user is allowed, toggle the scope.
Protected Sub RadioButton2_CheckedChanged(ByVal sender As Object, _
ByVal e As EventArgs)
If _manager.Personalization.CanEnterSharedScope AndAlso _
_manager.Personalization.Scope = PersonalizationScope.User Then
_manager.Personalization.ToggleScope()
End If
End Sub
</script>
<div>
<asp:Panel ID="Panel1" runat="server"
Borderwidth="1"
Width="230"
BackColor="lightgray"
Font-Names="Verdana, Arial, Sans Serif" >
<asp:Label ID="Label1" runat="server"
Text=" Display Mode"
Font-Bold="true"
Font-Size="8"
Width="120"
AssociatedControlID="DisplayModeDropdown"/>
<asp:DropDownList ID="DisplayModeDropdown" runat="server"
AutoPostBack="true"
Width="120"
OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
<asp:LinkButton ID="LinkButton1" runat="server"
Text="Reset User State"
ToolTip="Reset the current user's personalization data for the page."
Font-Size="8"
OnClick="LinkButton1_Click" />
<asp:Panel ID="Panel2" runat="server"
GroupingText="Personalization Scope"
Font-Bold="true"
Font-Size="8"
Visible="false" >
<asp:RadioButton ID="RadioButton1" runat="server"
Text="User"
AutoPostBack="true"
GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
<asp:RadioButton ID="RadioButton2" runat="server"
Text="Shared"
AutoPostBack="true"
GroupName="Scope"
OnCheckedChanged="RadioButton2_CheckedChanged" />
</asp:Panel>
</asp:Panel>
</div>
In the declarative markup for the Web page, on the <aspSample:TextDisplayWebPart>
element that references the control, note the AllowHide="false"
attribute, which prevents a user who is editing the control from being able to hide it. Load the page in a browser and use the Display Mode drop-down list control to change the display mode to edit mode. Next, click the verbs menu in the title bar of the WebPart control and click the edit verb. As the edit user interface (UI) is displayed, you can see that the UI to edit the Hidden property is now disabled, which occurred because you set the AllowHide property value to false
.
<%@ page language="C#" %>
<%@ register TagPrefix="uc1"
TagName="DisplayModeMenuCS"
Src="DisplayModeMenuCS.ascx" %>
<%@ register tagprefix="aspSample"
Namespace="Samples.AspNet.CS.Controls"
Assembly="TextDisplayWebPartCS"%>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<head id="Head1" runat="server">
<title>ASP.NET Example</title>
</head>
<body>
<form id="Form1" runat="server">
<asp:webpartmanager id="WebPartManager1" runat="server" />
<uc1:DisplayModeMenuCS ID="DisplayModeMenu1" runat="server" />
<asp:webpartzone
id="WebPartZone1"
runat="server"
title="Zone 1"
PartChromeType="TitleAndBorder">
<parttitlestyle font-bold="true" ForeColor="#3300cc" />
<partstyle
borderwidth="1px"
borderstyle="Solid"
bordercolor="#81AAF2" />
<zonetemplate>
<aspSample:TextDisplayWebPart
runat="server"
id="textwebpart"
title = "Text Content WebPart"
AllowHide="false" />
</zonetemplate>
</asp:webpartzone>
<asp:EditorZone id="EditZone1" Runat="server">
<ZoneTemplate>
<asp:AppearanceEditorPart ID="editor1" Runat="server" />
</ZoneTemplate>
</asp:EditorZone>
</form>
</body>
</html>
<%@ page language="VB" %>
<%@ register TagPrefix="uc1"
TagName="DisplayModeMenuVB"
Src="DisplayModeMenuVB.ascx" %>
<%@ register tagprefix="aspSample"
Namespace="Samples.AspNet.VB.Controls"
Assembly="TextDisplayWebPartVB"%>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<head id="Head1" runat="server">
<title>ASP.NET Example</title>
</head>
<body>
<form id="Form1" runat="server">
<asp:webpartmanager id="WebPartManager1" runat="server" />
<uc1:DisplayModeMenuVB ID="DisplayModeMenu1" runat="server" />
<asp:webpartzone
id="WebPartZone1"
runat="server"
title="Zone 1"
PartChromeType="TitleAndBorder">
<parttitlestyle font-bold="true" ForeColor="#3300cc" />
<partstyle
borderwidth="1px"
borderstyle="Solid"
bordercolor="#81AAF2" />
<zonetemplate>
<aspSample:TextDisplayWebPart
runat="server"
id="textwebpart"
title = "Text Content WebPart"
AllowHide="false" />
</zonetemplate>
</asp:webpartzone>
<asp:EditorZone id="EditZone1" Runat="server">
<ZoneTemplate>
<asp:AppearanceEditorPart ID="editor1" Runat="server" />
</ZoneTemplate>
</asp:EditorZone>
</form>
</body>
</html>
Remarks
The AllowHide property determines whether users can modify the Hidden property. In the default case, when the property value is true
, users can change the value when the control is being edited. By default, controls are not hidden and their Hidden property value is false
. When a WebPart control is being edited, if a user selects a check box to hide the control (which sets the Hidden property to true
), the control will no longer be visible when the page returns to browse mode.
Hidden controls are distinct from controls that are closed, because the Hidden property has a distinct meaning within the Web Parts control set. Closed controls are not even rendered on a page, and do not participate in page life cycle events. In contrast, while hidden WebPart controls are not visible to users, they are still rendered on a Web page, are still contained in a zone, and can still maintain connections with other WebPart controls as part of a Web Parts application.
This property cannot be set by themes or style sheet themes. For more information, see ThemeableAttribute and ASP.NET Themes and Skins.
The personalization scope of this property is set to Shared and can be modified only by authorized users. For more information, see PersonalizableAttribute and Web Parts Personalization Overview.