The RemoteGetClassObject (Opnum 3) method is used by clients to create an object reference for the class factory object.
-
HRESULT RemoteGetClassObject( [in] handle_t rpc, [in] ORPCTHIS* orpcthis, [out] ORPCTHAT* orpcthat, [in, unique] MInterfacePointer* pActProperties, [out] MInterfacePointer** ppActProperties );
rpc: This MUST specify an RPC binding handle as specified in [MS-RPCE] section 3.2.2.3.1.
orpcthis: This MUST specify an ORPCTHIS. The COMVERSION field SHOULD contain the negotiated version as specified in section 2.2.11. The extensions field MUST be set to NULL.
orpcthat: This MUST contain an ORPCTHAT. The extensions field MUST be set to NULL.
pActProperties: This MUST specify an MInterfacePointer that MUST contain an OBJREF_CUSTOM with a CLSID field set to CLSID_ActivationPropertiesIn (section 1.9) and a pObjectData field that MUST contain an activation properties BLOB (section 2.2.22). The iid field of the OBJREF portion of the structure MUST be set to IID_IActivationPropertiesIn (see section 1.9). An implementation MAY use this value as the IID of an interface with the local IDL attribute (section 2.2.27).<73>
-
The activation properties BLOB MUST contain properties marked Required in the following table and MAY contain properties marked Optional.
-
Property Name
Section
Required or Optional
InstantiationInfoData
Required
ScmRequestInfoData
Required
LocationInfoData
Required
SecurityInfoData
Optional
ActivationContextInfoData
Optional
InstanceInfoData
Optional
SpecialPropertiesData
Optional
-
Servers SHOULD ignore properties that they do not recognize.<74>
ppActProperties: This MUST contain an MInterfacePointer that MUST contain an OBJREF_CUSTOM with a CLSID field set to CLSID_ActivationPropertiesOut (section 1.9) and a pObjectData field that MUST contain an activation properties BLOB (section 2.2.22). The iid field of the OBJREF portion of the structure MUST be set to IID_ IActivationPropertiesOut (see section 1.9). An implementation MAY use this value as the IID of an interface with the local IDL attribute (section 2.2.27).<75>
-
The activation properties BLOB MUST contain all properties listed in the following table. Clients SHOULD ignore properties that they do not recognize.
-
Property Name
Section
Required or Optional
ScmReplyInfoData
Required
PropsOutInfo
Required
When processing this call, the object resolver MUST perform the operations specified in section 3.1.2.5.2.3.