Resolve common errors for the Intune Exchange Connector
This article can help Intune administrators resolve specific errors and messages about the operation of the Intune Exchange Connector.
Configuration failed and returned error code 0x0000001
Issue:
When you try to configure the Microsoft Intune Exchange Connector, you receive the following error message:
The Microsoft Intune Exchange Connector cannot connect to the Microsoft Exchange server.
The following Microsoft Exchange Server address could not be reached <Exchange server Name FQDN>
Verify that the FQDN of the exchange server address and credentials that you entered is correct and the server is running. The Microsoft Intune Exchange Connector does not support Exchange server arrays.
Error code: 0x0000001
This problem can occur if the Internet proxy settings are misconfigured.
Solution:
Configure proxy settings:
Contact the local network administrator to make sure that the proxy settings are configured correctly.
Use the Netsh winhttp command to configure the proxy server and add the required exclusion list. For example:
Netsh winhttp set proxy proxy-server="http=proxy.corp.domain.com" bypass-list"34*.*;134.132.*.*;10.*.*;localhost;*.corp.domain.com;*.staging.domain.com"
Configuration failed and returned error code 0x000000b
Issue:
When you try to configure the Microsoft Intune Exchange Connector, you receive the following error message:
The Microsoft Intune Exchange Connector experienced an error:
CertEnroll::CX509PrivateKey::Create: The system cannot find the file specified. 0x80070002 (WIN32: 2
ERROR_FILE_NOT_FOUND
Error code: 0x000000b
This problem can occur if the account that you used to sign in to Intune isn't an Intune Global Administrator account.
Solution:
Sign in to Intune with an account that is a Global Administrator, or add your account to the Global Admin group. For more information, see Role-based administration control (RBAC) with Microsoft Intune.
Configuration failed and returned error code 0x0000006
Issue:
When you try to configure the Microsoft Intune Exchange Connector, you receive the following error message:
The Microsoft Intune Exchange Connector cannot connect to Microsoft Intune
Verify that you are connected to the Internet, check the Microsoft Intune Service Status, and try to connect again.
Error code: 0x00000006
This error can occur if a proxy server is used to connect to the Internet and is blocking traffic to the Intune Service. To determine whether a proxy is in use, go to Control Panel > Internet Options, select the Connection tab, and then click LAN Settings.
Solution:
Option 1 - Remove the proxy settings to allow the computer to connect to the Internet without going through the proxy.
Option 2 - Configure your proxy server to allow communication to the Intune service, as documented in Intune Exchange Connector requirements.
Event 7000 or 7041: Microsoft Intune Exchange Connector Service won't start
Issue:
An iOS device fails to enroll in Intune and generates one of the following error messages:
Log Name: System
Source: Service Control Manager
Date: <time>
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: <computer>
Description:
The Microsoft Intune Exchange Connector Service service failed to start because of the following error:
The service did not start because of a logon failure.
Log Name: System
Source: Service Control Manager
Date: <time>
Event ID: 7041
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: <computer>
Description:
The WIEC service was unable to log on as .\WIEC_USER with the currently configured password because of the following error:
Logon failure: the user has not been granted the requested logon type at this computer.
Service: WIEC
Domain and account: .\WIEC_USER
This service account does not have the required user right "Log on as a service."
This problem can occur if the WIEC_User account doesn't have the Log on as service user right in the local policy.
Solution:
On the computer that runs the Intune Exchange Connector, assign the Log on as a service user right to the WIEC_User service account. If the computer is a node in a cluster, make sure to assign the Log on as a service user right to the cluster service account on all nodes in the cluster.
To assign the Log on as a service user right to the WIEC_User service account on the computer, follow these steps:
- Log on to the computer as an administrator or as a member of the Administrators group.
- Run secpol.msc to open the Local Security Policy.
- Go to Security settings > Local policies, and then select User Rights Assignment.
- In the right pane, double-click Log on as a service.
- Select Add User or Group, add WIEC_USER to the policy, and then select OK two times.
If the Log on as a service user right was assigned to WIEC_User but was later removed, contact the domain administrator to determine whether a Group Policy setting is overwriting it.