Timer.Interval Tulajdonság
Definíció
Fontos
Egyes információk olyan, kiadás előtti termékekre vonatkoznak, amelyek a kiadásig még jelentősen módosulhatnak. A Microsoft nem vállal kifejezett vagy törvényi garanciát az itt megjelenő információért.
Ezredmásodpercben kifejezve lekéri vagy beállítja azt az intervallumot, amelynél az Elapsed eseményt emelni szeretné.
public:
property double Interval { double get(); void set(double value); };
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
[System.ComponentModel.SettingsBindable(true)]
public double Interval { get; set; }
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
[<System.ComponentModel.SettingsBindable(true)>]
member this.Interval : double with get, set
Public Property Interval As Double
Tulajdonság értéke
Az események közötti Elapsed idő ezredmásodpercben. Az értéknek nullánál nagyobbnak kell lennie, és kisebbnek vagy egyenlőnek kell lennie az Int32.MaxValue értéknél. Az alapértelmezett érték 100 ezredmásodperc.
- Attribútumok
Kivételek
Az intervallum kisebb vagy egyenlő nullánál.
-vagy-
Az intervallum nagyobb, mint az Int32.MaxValue, és az időzítő jelenleg engedélyezve van. (Ha az időzítő jelenleg nincs engedélyezve, a rendszer addig nem ad kivételt, amíg engedélyezve nem lesz.)
Példák
Az alábbi példa létrehoz egy Timer objektumot, amely két másodpercenként (2000 ezredmásodpercenként) aktiválja Timer.Elapsed az eseményt, beállít egy eseménykezelőt az eseményhez, és elindítja az időzítőt. Az eseménykezelő minden alkalommal megjeleníti a ElapsedEventArgs.SignalTime tulajdonság értékét, amikor az elő van emelve.
using System;
using System.Timers;
public class Example
{
private static Timer aTimer;
public static void Main()
{
// Create a timer and set a two second interval.
aTimer = new System.Timers.Timer();
aTimer.Interval = 2000;
// Hook up the Elapsed event for the timer.
aTimer.Elapsed += OnTimedEvent;
// Have the timer fire repeated events (true is the default)
aTimer.AutoReset = true;
// Start the timer
aTimer.Enabled = true;
Console.WriteLine("Press the Enter key to exit the program at any time... ");
Console.ReadLine();
}
private static void OnTimedEvent(Object source, System.Timers.ElapsedEventArgs e)
{
Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime);
}
}
// The example displays output like the following:
// Press the Enter key to exit the program at any time...
// The Elapsed event was raised at 5/20/2015 8:48:58 PM
// The Elapsed event was raised at 5/20/2015 8:49:00 PM
// The Elapsed event was raised at 5/20/2015 8:49:02 PM
// The Elapsed event was raised at 5/20/2015 8:49:04 PM
// The Elapsed event was raised at 5/20/2015 8:49:06 PM
open System.Timers
let onTimedEvent source (e: ElapsedEventArgs) =
printfn $"The Elapsed event was raised at {e.SignalTime}"
// Create a timer and set a two second interval.
let aTimer = new Timer()
aTimer.Interval <- 2000
// Hook up the Elapsed event for the timer.
aTimer.Elapsed.AddHandler onTimedEvent
// Have the timer fire repeated events (true is the default)
aTimer.AutoReset <- true
// Start the timer
aTimer.Enabled <- true
printfn "Press the Enter key to exit the program at any time... "
stdin.ReadLine() |> ignore
// The example displays output like the following:
// Press the Enter key to exit the program at any time...
// The Elapsed event was raised at 5/20/2015 8:48:58 PM
// The Elapsed event was raised at 5/20/2015 8:49:00 PM
// The Elapsed event was raised at 5/20/2015 8:49:02 PM
// The Elapsed event was raised at 5/20/2015 8:49:04 PM
// The Elapsed event was raised at 5/20/2015 8:49:06 PM
Imports System.Timers
Public Module Example
Private aTimer As Timer
Public Sub Main()
' Create a timer and set a two second interval.
aTimer = New System.Timers.Timer()
aTimer.Interval = 2000
' Hook up the Elapsed event for the timer.
AddHandler aTimer.Elapsed, AddressOf OnTimedEvent
' Have the timer fire repeated events (true is the default)
aTimer.AutoReset = True
' Start the timer
aTimer.Enabled = True
Console.WriteLine("Press the Enter key to exit the program at any time... ")
Console.ReadLine()
End Sub
Private Sub OnTimedEvent(source As Object, e As System.Timers.ElapsedEventArgs)
Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime)
End Sub
End Module
' The example displays output like the following:
' Press the Enter key to exit the program at any time...
' The Elapsed event was raised at 5/20/2015 8:48:58 PM
' The Elapsed event was raised at 5/20/2015 8:49:00 PM
' The Elapsed event was raised at 5/20/2015 8:49:02 PM
' The Elapsed event was raised at 5/20/2015 8:49:04 PM
' The Elapsed event was raised at 5/20/2015 8:49:06 PM
Megjegyzések
A tulajdonsággal Interval meghatározhatja az esemény aktivált gyakoriságát Elapsed . Mivel az Timer osztály a rendszerórától függ, a felbontása megegyezik a rendszerórával. Ez azt jelenti, hogy az esemény a Elapsed rendszeróra felbontása által meghatározott időközönként aktiválódik, ha a Interval tulajdonság kisebb, mint a rendszeróra felbontása. Az alábbi példa 5 ezredmásodpercre állítja a Interval tulajdonságot. Ha olyan Windows rendszeren fut, amelynek a rendszerórája körülbelül 15 ezredmásodperc felbontással rendelkezik, az esemény körülbelül 15 ezredmásodpercenként aktiválódik, nem pedig 5 ezredmásodpercenként.
Note
A használt rendszeróra megegyezik a GetTickCount által használt órával, amelyet a timeBeginPeriod és a timeEndPeriod módosításai nem befolyásolnak.
using System;
using System.IO;
using System.Collections.Generic;
using System.Timers;
public class Example
{
private static Timer aTimer;
private static List<String> eventlog;
private static int nEventsFired = 0;
private static DateTime previousTime;
public static void Main()
{
eventlog = new List<String>();
StreamWriter sr = new StreamWriter(@".\Interval.txt");
// Create a timer with a five millisecond interval.
aTimer = new Timer(5);
aTimer.Elapsed += OnTimedEvent;
// Hook up the Elapsed event for the timer.
aTimer.AutoReset = true;
sr.WriteLine("The timer should fire every {0} milliseconds.",
aTimer.Interval);
aTimer.Enabled = true;
Console.WriteLine("Press the Enter key to exit the program... ");
Console.ReadLine();
foreach (var item in eventlog)
sr.WriteLine(item);
sr.Close();
Console.WriteLine("Terminating the application...");
}
private static void OnTimedEvent(Object source, ElapsedEventArgs e)
{
eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})",
e.SignalTime,
nEventsFired++ == 0 ?
0.0 : (e.SignalTime - previousTime).TotalMilliseconds));
previousTime = e.SignalTime;
if (nEventsFired == 20) {
Console.WriteLine("No more events will fire...");
aTimer.Enabled = false;
}
}
}
// The example writes output like the following to a file:
// The timer should fire every 5 milliseconds.
// Elapsed event at 08:42:49.370344 (0)
// Elapsed event at 08:42:49.385345 (15.0015)
// Elapsed event at 08:42:49.400347 (15.0015)
// Elapsed event at 08:42:49.415348 (15.0015)
// Elapsed event at 08:42:49.430350 (15.0015)
// Elapsed event at 08:42:49.445351 (15.0015)
// Elapsed event at 08:42:49.465353 (20.002)
// Elapsed event at 08:42:49.480355 (15.0015)
// Elapsed event at 08:42:49.495356 (15.0015)
// Elapsed event at 08:42:49.510358 (15.0015)
// Elapsed event at 08:42:49.525359 (15.0015)
// Elapsed event at 08:42:49.540361 (15.0015)
// Elapsed event at 08:42:49.555362 (15.0015)
// Elapsed event at 08:42:49.570364 (15.0015)
// Elapsed event at 08:42:49.585365 (15.0015)
// Elapsed event at 08:42:49.605367 (20.002)
// Elapsed event at 08:42:49.620369 (15.0015)
// Elapsed event at 08:42:49.635370 (15.0015)
// Elapsed event at 08:42:49.650372 (15.0015)
// Elapsed event at 08:42:49.665373 (15.0015)
open System
open System.IO
open System.Timers
let aTimer = new Timer 5
let eventlog = ResizeArray()
let mutable nEventsFired = 0
let mutable previousTime = DateTime()
let onTimedEvent source (e: ElapsedEventArgs) =
String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})", e.SignalTime, if nEventsFired = 0 then 0. else (e.SignalTime - previousTime).TotalMilliseconds)
|> eventlog.Add
nEventsFired <- nEventsFired + 1
previousTime <- e.SignalTime
if nEventsFired = 20 then
printfn "No more events will fire..."
aTimer.Enabled <- false
[<EntryPoint>]
let main _ =
use sr = new StreamWriter(@".\Interval.txt")
// Create a timer with a five millisecond interval.
aTimer.Elapsed.AddHandler onTimedEvent
// Hook up the Elapsed event for the timer.
aTimer.AutoReset <- true
sr.WriteLine $"The timer should fire every {aTimer.Interval} milliseconds."
aTimer.Enabled <- true
printfn "Press the Enter key to exit the program... "
stdin.ReadLine() |> ignore
for item in eventlog do
sr.WriteLine item
printfn "Terminating the application..."
0
// The example writes output like the following to a file:
// The timer should fire every 5 milliseconds.
// Elapsed event at 08:42:49.370344 (0)
// Elapsed event at 08:42:49.385345 (15.0015)
// Elapsed event at 08:42:49.400347 (15.0015)
// Elapsed event at 08:42:49.415348 (15.0015)
// Elapsed event at 08:42:49.430350 (15.0015)
// Elapsed event at 08:42:49.445351 (15.0015)
// Elapsed event at 08:42:49.465353 (20.002)
// Elapsed event at 08:42:49.480355 (15.0015)
// Elapsed event at 08:42:49.495356 (15.0015)
// Elapsed event at 08:42:49.510358 (15.0015)
// Elapsed event at 08:42:49.525359 (15.0015)
// Elapsed event at 08:42:49.540361 (15.0015)
// Elapsed event at 08:42:49.555362 (15.0015)
// Elapsed event at 08:42:49.570364 (15.0015)
// Elapsed event at 08:42:49.585365 (15.0015)
// Elapsed event at 08:42:49.605367 (20.002)
// Elapsed event at 08:42:49.620369 (15.0015)
// Elapsed event at 08:42:49.635370 (15.0015)
// Elapsed event at 08:42:49.650372 (15.0015)
// Elapsed event at 08:42:49.665373 (15.0015)
Imports System.Collections.Generic
Imports System.IO
Imports System.Timers
Module Example
Private WithEvents aTimer As Timer
Private eventlog As List(Of String)
Private nEventsFired As Integer = 0
Private previousTime As Date
Public Sub Main()
eventlog = New List(Of String)()
Dim sr As New StreamWriter(".\Interval.txt")
' Create a timer with a five millisecond interval.
aTimer = New Timer(5)
aTimer.AutoReset = True
sr.WriteLine("The timer should fire every {0} milliseconds.",
aTimer.Interval)
aTimer.Enabled = True
Console.WriteLine("Press the Enter key to exit the program... ")
Console.ReadLine()
For Each item In eventlog
sr.WriteLine(item)
Next
sr.Close()
Console.WriteLine("Terminating the application...")
End Sub
Private Sub OnTimedEvent(source As Object, e As ElapsedEventArgs) _
Handles aTimer.Elapsed
eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})",
e.SignalTime,
If(nEventsFired = 0,
0.0, (e.SignalTime - previousTime).TotalMilliseconds)))
nEventsFired += 1
previousTime = e.SignalTime
if nEventsFired = 20 Then
Console.WriteLine("No more events will fire...")
aTimer.Enabled = False
End If
End Sub
End Module
' The example displays the following output:
' The timer should fire every 5 milliseconds.
' Elapsed event at 08:42:49.370344 (0)
' Elapsed event at 08:42:49.385345 (15.0015)
' Elapsed event at 08:42:49.400347 (15.0015)
' Elapsed event at 08:42:49.415348 (15.0015)
' Elapsed event at 08:42:49.430350 (15.0015)
' Elapsed event at 08:42:49.445351 (15.0015)
' Elapsed event at 08:42:49.465353 (20.002)
' Elapsed event at 08:42:49.480355 (15.0015)
' Elapsed event at 08:42:49.495356 (15.0015)
' Elapsed event at 08:42:49.510358 (15.0015)
' Elapsed event at 08:42:49.525359 (15.0015)
' Elapsed event at 08:42:49.540361 (15.0015)
' Elapsed event at 08:42:49.555362 (15.0015)
' Elapsed event at 08:42:49.570364 (15.0015)
' Elapsed event at 08:42:49.585365 (15.0015)
' Elapsed event at 08:42:49.605367 (20.002)
' Elapsed event at 08:42:49.620369 (15.0015)
' Elapsed event at 08:42:49.635370 (15.0015)
' Elapsed event at 08:42:49.650372 (15.0015)
' Elapsed event at 08:42:49.665373 (15.0015)
Ha az alkalmazás nagyobb felbontást igényel, mint amit az Timer osztály vagy a rendszeróra kínál, használja a nagy felbontású multimédiás időzítőket. Lásd : Útmutató: Az High-Resolution időzítő használata.
Ha az időköz a Timer kezdés után van beállítva, a darabszám alaphelyzetbe áll. Ha például 5 másodpercre állítja az intervallumot, majd beállítja a Enabled tulajdonságot true, a szám a beállítás időpontjában Enabled kezdődik. Ha 3 másodperces szám esetén 10 másodpercre állítja vissza az időközt, az Elapsed esemény az első alkalommal 13 másodpercre emelkedik a beállítás után Enabledtrue.
Ha Enabled be van állítva true és AutoReset be van állítva false, a Timer rendszer csak egyszer állítja be az Elapsed eseményt, az intervallum első elteltekor.
Enabled ekkor a következőre van falseállítva: .
Note
Ha Enabled és mindkettőre van állítva AutoReset, és az időzítő korábban engedélyezve lett, a false tulajdonság beállítása miatt az Interval esemény egyszer lesz előállítva, mintha a Elapsed tulajdonság értéke lett volnaEnabled.true Ha az esemény növelése nélkül szeretné beállítani az időközt, ideiglenesen beállíthatja a Enabled tulajdonságot truea Interval kívánt időintervallumra, majd azonnal visszaállíthatja a Enabled tulajdonságot a kívánt időpontra false.