Extract_CPIC_Side_Information (CPI-C)

The Extract_CPIC_Side_Information call (function name xcmesi) returns the side information for an entry number or symbolic destination name.

Syntax

  
CM_ENTRY Extract_CPIC_Side_Information(   
  CM_INT32 FAR *entry_number,          
  unsigned char FAR *sym_dest_name,    
  SIDE_INFO FAR *side_info_entry,      
  CM_INT32 FAR *side_info_entry_length,    
    CM_INT32 FAR *return_code            
);  

Parameters

entry_number
Supplied parameter. Specifies the number (index) of the side information entry to be returned. The first entry is 1.

The program can look up the side information entry by the symbolic destination name instead. To accomplish this, set the entry number to zero.

sym_dest_name
Supplied parameter. Specifies the symbolic destination name to search for.

If entry_number is set to a number greater than zero, this parameter is ignored.

side_info_entry
Returned parameter. Specifies the side information entry. For a detailed explanation of the side information entry, see Set_CPIC_Side_Information.

Each field in the side information structure is left-aligned and padded with spaces on the right as necessary.

side_info_entry_length
Supplied parameter. Always 124.

return_code
The code returned from this call. The valid return codes are listed later in this topic.

Return Codes

CM_OK
Primary return code; the call executed successfully.

CM_PROGRAM_PARAMETER_CHECK
Primary return code; one of the following occurred:

  • The entry_number specified a number larger than the maximum number of entries in the side information table or a number that is less than zero.

  • The sym_dest_name parameter is invalid and entry_number is set to zero.

  • The side_info_entry_length parameter is not set to 124.

    CM_PRODUCT_SPECIFIC_ERROR
    Primary return code; a product-specific error occurred and has been logged in the products error log.

State Changes

This call is not associated with a conversation and can be in any state.

There is no state change.

Remarks

The security password is never returned. If the security user identifier in the side information is not set, the security user identifier field is returned as all spaces.