MsSna_Connection8022Dlc Class
Describes a type of SNA connection that uses DLC 802.2 protocol over a Token Ring or Ethernet.
The following syntax is simplified from MOF code.
Syntax
class MsSna_Connection8022Dlc : MsSna_Connection
{
String Address;
sint16 DlcRetryLimit;
sint16 DlcTimerT1;
sint16 DlcTimerT2;
sint16 DlcXidRetry;
sint16 DlcRecvThresh;
sint16 DlcSendLimit;
sint16 DlcRemoteSAP;
sint16 DLCType;
sint16 DlcLocalSAP;
sint32 MaxBtu;
};
Parameters
Address
Data Type: String Qualifiers: MAXLEN(12), TOUPPERCASE Access Type: Read/Write
The 12-digit hexadecimal remote network address. You can receive the correct value for Address by contacting the administrator of the remote system.
DlcRetryLimit
Data Type: sint16 Qualifiers: MINVALUE(0), MAXVALUE(255) Access Type: Read/Write
The number of times that the local system should retransmit a frame if no response is received from the remote system.
DlcTimerT1
Data Type: sint16 Access Type: Read/Write
The amount of time that the local system should wait for the remote system to respond to a transmission before the local system tries again. The following table describes the possible values for DlcTimer.
Value | Description |
---|---|
0 | Default |
1 | 200 ms |
2 | 400 ms |
3 | 600 ms |
4 | 800 ms |
5 | 1000 ms |
6 | 1 s |
7 | 2 s |
8 | 3 s |
9 | 4 s |
10 | 5 s |
DlcTimerT2
Data Type: sint16 Access Type: Read/Write
The maximum amount of time that should be allowed before the local system sends an acknowledgment of a received transmission. The following table describes the possible values for DlcTimerT2.
Value | Description |
---|---|
0 | Default |
1 | 40 ms |
2 | 80 ms |
3 | 120 ms |
4 | 160 ms |
5 | 200 ms |
6 | 400 ms |
7 | 800 ms |
8 | 1200 ms |
9 | 1600 ms |
10 | 2000 ms |
DlcXidRetry
Data Type: sint16 Qualifiers: QualiferValueHere Access Type: Read/Write
The amount of time that the link can be inactive before the local system treats it as nonfunctioning and shuts it down. The following table describes the possible values for DlcXidRetry.
Value | Description |
---|---|
0 | 1 s |
1 | 2 s |
2 | 3 s |
3 | 4 s |
4 | 5 s |
5 | 5 s (2) |
6 | 10 s |
7 | 15 s |
8 | 20 s |
9 | 25 s |
DlcXidRetry
Data Type: sint16 Qualifiers: MINVALUE(0), MAXVALUE(30) Access Type: Read/Write
The number of times that the local system should retransmit an XID, an identifying message, if no response is received from the remote system.
DlcRecvThresh
Data Type: sint16 Qualifiers: MINVALUE(0), MAXVALUE(127) Access Type: Read/Write
The maximum number of frames that the local system can receive from the remote system before sending a response.
DlcSendLimit
Data Type: sint16 Qualifiers: MINVALUE(0), MAXVALUE(127) Access Type: Read/Write
The maximum number of frames that the local system can send without receiving a response from the remote system.
DlcRemoteSAP
Data Type: sint16 Qualifiers: MINVALUE(4), MAXVALUE(252) Access Type: Read/Write
A 2-digit hexadecimal number that is a multiple of 04, between 04 and EC. See your Token Ring or Ethernet manual for more information.
DLCType
Data Type: sint16 Access Type: Read-Only
The DLC type. The following table describes the possible values for DLCType.
Value | Description |
---|---|
0 | Token |
1 | Ether |
DlcLocalSAP
Data Type: sint16 Qualifiers: MINVALUE(4), MAXVALUE(252) Access Type: Read/Write
A 2-digit hexadecimal number that is a multiple of 04, between 04 and EC. See your Token Ring or Ethernet manual for more information.
MaxBtu
Data Type: sint16 Qualifiers: MINVALUE(265), MAXVALUE(16393) Access Type: Read/Write
The maximum Basic Transmission Unit (BTU) Length.
Requirements
Platforms: Windows Server 2022, Windows Server 2019, Windows Server 2016, Windows 11, and Windows 10
See Also
WMISNA WMI Provider Classes
Administration and Management Programmer's Guide