Szerkesztés

Megosztás a következőn keresztül:


MsSna_PrintSessionAppc Class

Extends a print session. Uses APPC LU 6.2 protocols to communicate with the host.

The following syntax is simplified from MOF code.

Syntax

  
class MsSna_PrintSessionAppc : MsSna_PrintSession  
{  
   String LocalLUAlias;  
   String RemoteLUAlias;  
   String RemoteFQName;  
   sint16 Remote;  
   String Mode;  
   String UserId;  
   String Password;  
   String AS400Device;  
   sint16 System36;  
   sint16 HostPrintTransform;  
   sint16 DeviceType;  
   String FontId;  
   String MsgQName;  
   String MsgLibName;  
   String PrinterName;  
   sint16 PaperSrc1;  
   sint16 PaperSrc2;  
   sint16 CodePage899;  
   String SpecialObjName;  
   String SpecialLibName;  
};  

Parameters

LocalLUAlias
Data Type: String Qualifiers: MAXLEN(8), TOUPPERCASEAccess Type: Read/Write

The local LU alias to be used for this print session. Valid only when a RemoteLUAlias is provided.

RemoteLUAlias
Data Type: String Qualifiers: MAXLEN(8), TOUPPERCASEAccess Type: Read/Write

The remote LU alias. Valid only if a fully qualified name is not provided.

RemoteFQName
Data Type: String Qualifiers: MAXLEN(17)Access Type: Read/Write

The remote LU fully qualified name. Valid only if RemoteLUAlias and LocalLUAlias are not provided.

Remote
Data Type: sint16 Access Type: Read/Write

A value that specifies what type of connection to use: either a remote APPC LU alias or a fully qualified name. The following table describes the possible values for Remote.

Value Description
0 Alias
1 Fully qualified name

Mode
Data Type: String Qualifiers: MAXLEN(8), TOUPPERCASEAccess Type: Read/Write

The name of the mode to use. The default mode name is QPCSUPP.

UserId
Data Type: String Qualifiers: MAXLEN(10)Access Type: Read/Write

The remote user name.

Password
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

The remote password.

AS400Device
Data Type: String Qualifiers: MAXLEN(10), TOUPPERCASE Access Type: Read/Write

The name for the IBM i printer device. AS400Device should be a descriptive name that distinguishes different printers on the network.

System36
Data Type: sint16 Access Type: Read/Write

A value that indicates whether the remote system is an IBM i or a System/36. The following table describes the possible values for System36.

Value Description
0 AS400
1 System/36

HostPrintTransform
Data Type: sint16 Access Type: Read/Write

A value that indicates whether Host Print Transform (HPT) will be used. The following table describes the possible values for HostPrintTransform.

Value Description
0 FALSE
1 TRUE

DeviceType
Data Type: sint16 Access Type: Read/Write

The print device for Host Print Transform. The following table describes the possible values for DeviceType.

Value Description
0 5224
1 3812

The default value for DeviceType is 5224.

FontId
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

A font, which should be used instead of the default.

MsgQName
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

The qualified name of the message queue to which operational messages for this device are sent.

MsgLibName
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

The name of the library in which the message queue is located.

PrinterName
Data Type: TOUPPERCASE Access Type: Read/Write

The printer type to be used with Host Print Transform. For more information on the possible values for PrinterName, see the Remarks section.

PaperSrc1
Data Type: sint16 Access Type: Read/Write

The type of paper used in paper source 1. The following table describes the possible values for PaperSrc1.

Value Description
0 Default
1 Letter (8.5 x 11 inches)
2 Legal (8.5 x 14 inches)
3 Executive (7.25 x 10.5 inches)
4 A4 (210 x 297 mm)
5 A5 (148 x 210 mm)
6 B5 (182 x 257 mm)
7 Continuous Form (8.0 inches)
8 Continuous Form (13.2 inches)
9 None

PaperSrc2
Data Type: sint16 Access Type: Read/Write

The type of paper used in paper source 2. The following table describes the possible values for PaperSrc2.

Value Description
0 Default
1 Letter (8.5 x 11 inches)
2 Legal (8.5 x 14 inches)
3 Executive (7.25 x 10.5 inches)
4 A4 (210 x 297 mm)
5 A5 (148 x 210 mm)
6 B5 (182 x 257 mm)
7 Continuous Form (8.0 inches)
8 Continuous Form (13.2 inches)
9 None

CodePage899
Data Type: sint16 Access Type: Read/Write

A value that indicates whether code page 899 is used. The following table describes the possible values of CodePage899.

Value Description
0 FALSE
1 TRUE

SpecialObjName
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

The name of the special object.

SpecialLibName
Data Type: String Qualifiers: MAXLEN(10) Access Type: Read/Write

The name of the special library.

Remarks

The following table describes the possible values for PrinterName.

Value Description
0 *IBM2380
1 *IBM2381
2 *IBM2390
3 *IBM2391
4 *IBM3812
5 *IBM3816
6 *IBM3912HP
7 *IBM3916HP
8 *IBM39302
9 *IBM39303
10 *IBM4019
11 *IBM4019HP
12 *IBM4029
13 *IBM4029HP
14 *IBM4037
15 *IBM4037HP
16 *IBM4070
17 *IBM4070EP
18 *IBM42011
19 *IBM42012
20 *IBM42013
21 *IBM42021
22 *IBM42022
23 *IBM42023
24 *IBM42071
25 *IBM42072
26 *IBM42081
27 *IBM4212
28 *IBM4216
29 *IBM4226
30 *IBM4230
31 *IBM4232
32 *IBM47121
33 *IBM47122
34 *IBM47221
35 *IBM47222
36 *IBM4770
37 *IBM5152
38 *IBM5210
39 *IBM5202
40 *IBM5204
41 *IBM5216
42 *IBM6408
43 *IBM6412
44 *CPQPM15
45 *CPQPM20
46 *HPII
47 *HPIID
48 *HPIIP
49 *HPIIID
50 *HPIIIP
51 *HPIIISI
52 *HP4
53 *HP500
54 *HP550C
55 *HP560C
56 *HPPAINT
57 *EPAP2250
58 *EPAP3250
59 *EPAP5000
60 *EPAP5500
61 *EPDFX5000
62 *EPDFX8000
63 *EPDFX850
64 *EPDFX870
65 *EPDFX1170
66 *EPLQ570
67 *EPLQ860
68 *EPLQ870
69 *EPLQ1070
70 *EPLQ1170
71 *EPLX810
72 *EPLQ510
73 *EPLQ2550
74 *EPSQ870
75 *EPSQ1170
76 *EPEPL7000
77 *EPEPL8000
78 *OKI320IBM
79 *OKI321IBM
80 *OKI390IBM
81 *OKI393IBM
82 *OKI590IBM
83 *OKI591IBM
84 *OKI400
85 *OKI800
86 *OKI810
87 *OKI820
88 *OKI3410
89 *NECP2
90 *NEC2200
91 *NECP2200XE
92 *NECP5200
93 *NECP5300
94 *NECP6200
95 *NECP6300
96 *PAN1123EP
97 *PAN1124
98 *PAN1124IEP
99 *PAN1180EP
100 *PAN1180IEP
101 *PAN1191
102 *PAN1624EP
103 *PAN1654EP
104 *PAN1695EP
105 *PAN2123EP
106 *PAN2124
107 *PAN2180
108 *PAN2624EP
109 *PAN4410
110 *PAN4420
111 *PAN4430
112 *PAN4450IHP
113 *PAN4451HP
114 *XRX4215MRP
115 *XRX4219MRP
116 *XRX4220MRP
117 *XRX4235
118 *XRX4700II
119 *WSCST

Requirements

Platforms: Windows Server 2022, Windows Server 2019, Windows Server 2016, Windows 11, and Windows 10

See Also

WMISNA WMI Provider Classes
Administration and Management Programmer's Guide