Szerkesztés

Megosztás a következőn keresztül:


Bug Check 0x125: NMR_INVALID_STATE

The NMR_INVALID_STATE bug check has a value of 0x00000125. This indicates that NMR (network module registrar) has detected an invalid state. See parameter 1 for the state type.

Important

This article is for programmers. If you're a customer who has received a blue screen error code while using your computer, see Troubleshoot blue screen errors.

NMR_INVALID_STATE Parameters

Parameter Description
1

The subtype of the bugcheck.

0x0 : Machine Check Exception

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

Parameter 3 - High order 32-bits of the MCi_STATUS value.

Parameter 4 - Low order 32-bits of the MCi_STATUS value.

0x1 : Corrected Machine Check

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x2 : Corrected Platform Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x3 : Non-maskable Interrupt

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x4 : PCI Express Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x5 : Generic Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x6 : INIT Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x7 : BOOT Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x8 : SCI Generic Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0x9 : Itanium Machine Check Abort

Parameter 2 - Address of the WHEA_ERROR_RECORD structure. Parameter 3 - Length in bytes of the SAL log. Parameter 4 - Address of the SAL log.

0xa : Itanium Corrected Machine Check

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.

0xb : Itanium Corrected Platform Error

Parameter 2 - Address of the WHEA_ERROR_RECORD structure.
2 Pointer to the NMI Handle
3 Pointer to the expected type, when available
4 Reserved