Policy CSP - ADMX_WinInit
Tip
This CSP contains ADMX-backed policies which require a special SyncML format to enable or disable. You must specify the data type in the SyncML as <Format>chr</Format>
. For details, see Understanding ADMX-backed policies.
The payload of the SyncML must be XML-encoded; for this XML encoding, there are a variety of online encoders that you can use. To avoid encoding the payload, you can use CDATA if your MDM supports it. For more information, see CDATA Sections.
DisableNamedPipeShutdownPolicyDescription
Scope | Editions | Applicable OS |
---|---|---|
✅ Device ❌ User |
✅ Pro ✅ Enterprise ✅ Education ✅ Windows SE ✅ IoT Enterprise / IoT Enterprise LTSC |
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later ✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later ✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later ✅ Windows 11, version 21H2 [10.0.22000] and later |
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/DisableNamedPipeShutdownPolicyDescription
This policy setting controls the legacy remote shutdown interface (named pipe). The named pipe remote shutdown interface is needed in order to shutdown this system from a remote Windows XP or Windows Server 2003 system.
If you enable this policy setting, the system doesn't create the named pipe remote shutdown interface.
If you disable or don't configure this policy setting, the system creates the named pipe remote shutdown interface.
Description framework properties:
Property name | Property value |
---|---|
Format | chr (string) |
Access Type | Add, Delete, Get, Replace |
Tip
This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to Enabling a policy.
ADMX mapping:
Name | Value |
---|---|
Name | DisableNamedPipeShutdownPolicyDescription |
Friendly Name | Turn off legacy remote shutdown interface |
Location | Computer Configuration |
Path | Windows Components > Shutdown Options |
Registry Key Name | Software\Microsoft\Windows\CurrentVersion\Policies\System |
Registry Value Name | DisableShutdownNamedPipe |
ADMX File Name | WinInit.admx |
Hiberboot
Scope | Editions | Applicable OS |
---|---|---|
✅ Device ❌ User |
✅ Pro ✅ Enterprise ✅ Education ✅ Windows SE ✅ IoT Enterprise / IoT Enterprise LTSC |
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later ✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later ✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later ✅ Windows 11, version 21H2 [10.0.22000] and later |
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/Hiberboot
This policy setting controls the use of fast startup.
If you enable this policy setting, the system requires hibernate to be enabled.
If you disable or don't configure this policy setting, the local setting is used.
Description framework properties:
Property name | Property value |
---|---|
Format | chr (string) |
Access Type | Add, Delete, Get, Replace |
Tip
This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to Enabling a policy.
ADMX mapping:
Name | Value |
---|---|
Name | Hiberboot |
Friendly Name | Require use of fast startup |
Location | Computer Configuration |
Path | System > Shutdown |
Registry Key Name | Software\Policies\Microsoft\Windows\System |
Registry Value Name | HiberbootEnabled |
ADMX File Name | WinInit.admx |
ShutdownTimeoutHungSessionsDescription
Scope | Editions | Applicable OS |
---|---|---|
✅ Device ❌ User |
✅ Pro ✅ Enterprise ✅ Education ✅ Windows SE ✅ IoT Enterprise / IoT Enterprise LTSC |
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later ✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later ✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later ✅ Windows 11, version 21H2 [10.0.22000] and later |
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/ShutdownTimeoutHungSessionsDescription
This policy setting configures the number of minutes the system waits for the hung logon sessions before proceeding with the system shutdown.
If you enable this policy setting, the system waits for the hung logon sessions for the number of minutes specified.
If you disable or don't configure this policy setting, the default timeout value is 3 minutes for workstations and 15 minutes for servers.
Description framework properties:
Property name | Property value |
---|---|
Format | chr (string) |
Access Type | Add, Delete, Get, Replace |
Tip
This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to Enabling a policy.
ADMX mapping:
Name | Value |
---|---|
Name | ShutdownTimeoutHungSessionsDescription |
Friendly Name | Timeout for hung logon sessions during shutdown |
Location | Computer Configuration |
Path | Windows Components > Shutdown Options |
Registry Key Name | Software\Microsoft\Windows\CurrentVersion\Policies\System |
ADMX File Name | WinInit.admx |