Szerkesztés

Megosztás a következőn keresztül:


CIM_Slot class

The CIM_Slot class represents connectors into which packages are inserted. For example, a physical package that is a disk drive can be inserted into an SCA slot, or a card (a subclass of CIM_PhysicalPackage) can be inserted into a 16-, 32-, or 64-bit expansion slot on a hosting board. PCI or PCMCIA Type III Slots are examples of the latter.

Important

The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[abstract, UUID("{FAF76B86-798C-11D2-AAD1-006008C78BC7}"), AMENDMENT]
class CIM_Slot : CIM_PhysicalConnector
{
  string   Caption;
  string   ConnectorPinout;
  uint16   ConnectorType[];
  string   CreationClassName;
  string   Description;
  real32   HeightAllowed;
  datetime InstallDate;
  real32   LengthAllowed;
  string   Manufacturer;
  uint16   MaxDataWidth;
  string   Model;
  string   Name;
  uint16   Number;
  string   OtherIdentifyingInfo;
  string   PartNumber;
  boolean  PoweredOn;
  string   PurposeDescription;
  string   SerialNumber;
  string   SKU;
  boolean  SpecialPurpose;
  string   Status;
  boolean  SupportsHotPlug;
  string   Tag;
  uint32   ThermalRating;
  uint16   VccMixedVoltageSupport[];
  string   Version;
  uint16   VppMixedVoltageSupport[];
};

Members

The CIM_Slot class has these types of members:

Properties

The CIM_Slot class has these properties.

Caption

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64), DisplayName ("Caption")

Short textual description of the object.

This property is inherited from CIM_ManagedSystemElement.

ConnectorPinout

Data type: string

Access type: Read-only

Free-form string that describes the pin configuration and signal use of a physical connector.

This property is inherited from CIM_PhysicalConnector.

ConnectorType

Data type: uint16 array

Access type: Read-only

Qualifiers: Override ("ConnectorType"), MappingStrings ("MIF.DMTF|System Slot|004.2")

Type of physical connector. An array is specified to allow the description of combinations of connector information. For example, one array entry could specify RS-232, another DB-25, and a third could define the connector as "Male".

This property is inherited from CIM_PhysicalConnector.

0

Unknown

1

Other

2

Male

3

Female

4

Shielded

5

Unshielded

6

SCSI (A) High-density (50 pins)

7

SCSI (A) Low-density (50 pins)

8

SCSI (P) High-density (68 pins)

9

SCSI SCA-I (80 pins)

10

SCSI SCA-II (80 pins)

11

SCSI Fibre Channel (DB-9, Copper)

12

SCSI Fibre Channel (Fibre)

13

SCSI Fibre Channel SCA-II (40 pins)

14

SCSI Fibre Channel SCA-II (20 pins)

15

SCSI Fibre Channel BNC

16

ATA 3-1/2 Inch (40 pins)

17

ATA 2-1/2 Inch (44 pins)

18

ATA-2

19

ATA-3

20

ATA/66

21

DB-9

22

DB-15

23

DB-25

24

DB-36

25

RS-232C

26

RS-422

27

RS-423

28

RS-485

29

RS-449

30

V.35

31

X.21

32

IEEE-488

33

AUI

34

UTP Category 3

35

UTP Category 4

36

UTP Category 5

37

BNC

38

RJ11

39

RJ45

40

Fiber MIC

41

Apple AUI

42

Apple GeoPort

43

PCI

44

ISA

45

EISA

46

VESA

47

PCMCIA

48

PCMCIA Type I

49

PCMCIA Type II

50

PCMCIA Type III

51

ZV Port

52

CardBus

53

USB

54

IEEE 1394

55

HIPPI

56

HSSDC (6 pins)

57

GBIC

58

DIN

59

Mini-DIN

60

Micro-DIN

61

PS/2

62

Infrared

63

HP-HIL

64

Access.bus

65

NuBus

66

Centronics

67

Mini-Centronics

68

Mini-Centronics Type-14

69

Mini-Centronics Type-20

70

Mini-Centronics Type-26

71

Bus Mouse

72

ADB

73

AGP

74

VME Bus

75

VME64

76

Proprietary

77

Proprietary Processor Card Slot

78

Proprietary Memory Card Slot

79

Proprietary I/O Riser Slot

80

PCI-66MHZ

81

AGP2X

82

AGP4X

83

PC-98

84

PC-98-Hireso

85

PC-H98

86

PC-98Note

87

PC-98Full

88

SSA SCSI

89

Circular

90

On Board IDE Connector

91

On Board Floppy Connector

92

9 Pin Dual Inline

93

25 Pin Dual Inline

94

50 Pin Dual Inline

95

68 Pin Dual Inline

96

On Board Sound Connector

97

Mini-jack

98

PCI-X

99

Sbus IEEE 1396-1993 32 bit

100

Sbus IEEE 1396-1993 64 bit

101

MCA

102

GIO

103

XIO

104

HIO

105

NGIO

106

PMC

107

MTRJ

108

VF-45

109

Future I/O

110

SC

111

SG

112

Electrical

113

Optical

114

Ribbon

115

GLM

116

1x9

117

Mini SG

118

LC

119

HSSC

120

VHDCI Shielded (68 pins)

121

InfiniBand

CreationClassName

Data type: string

Access type: Read-only

Qualifiers: CIM_Key, MaxLen (256)

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified.

This property is inherited from CIM_PhysicalElement.

Description

Data type: string

Access type: Read-only

Qualifiers: DisplayName ("Description")

Textual description of the object.

This property is inherited from CIM_ManagedSystemElement.

HeightAllowed

Data type: real32

Access type: Read-only

Qualifiers: Units ("inches")

Maximum height, in inches, of an adapter card that can be inserted into the slot.

InstallDate

Data type: datetime

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5"), DisplayName ("Install Date")

Date and time the object was installed. This property does not need a value to indicate that the object is installed.

This property is inherited from CIM_ManagedSystemElement.

LengthAllowed

Data type: real32

Access type: Read-only

Qualifiers: Units ("inches")

Maximum length, in inches, of an adapter card that can be inserted into the slot.

Manufacturer

Data type: string

Access type: Read-only

Qualifiers: MaxLen (256)

Organization that produced the physical element. For more information, see the Vendor property of CIM_Product.

This property is inherited from CIM_PhysicalElement.

MaxDataWidth

Data type: uint16

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|System Slot|004.3"), Units ("bits")

Maximum bus width, in bits, of adapter cards that can be inserted into the slot.

8 (0)

16 (1)

32 (2)

64 (3)

128 (4)

Model

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

Name by which the physical element is generally known.

This property is inherited from CIM_PhysicalElement.

Name

Data type: string

Access type: Read-only

Qualifiers: DisplayName ("Name")

Label by which the object is known. When subclassed, this property can be overridden to be a key property.

This property is inherited from CIM_ManagedSystemElement.

Number

Data type: uint16

Access type: Read-only

Physical slot number, which can be used as an index into a system slot table, to determine whether the slot is physically occupied.

OtherIdentifyingInfo

Data type: string

Access type: Read-only

Additional data, beyond asset tag information, that can be used to identify a physical element. One example is bar-code data that is associated with an element, which also has an asset tag. Note that if only bar-code data is available, and is unique and able to be used as an element key, this property would be null and the bar-code data would be used as the class key in the Tag property.

This property is inherited from CIM_PhysicalElement.

PartNumber

Data type: string

Access type: Read-only

Qualifiers: MaxLen (256)

Part number assigned by the organization that produced or manufactured the physical element.

This property is inherited from CIM_PhysicalElement.

PoweredOn

Data type: boolean

Access type: Read-only

If TRUE, the physical element is powered on.

This property is inherited from CIM_PhysicalElement.

PurposeDescription

Data type: string

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_Slot.SpecialPurpose")

Free-form string that describes how this slot is physically unique and that it may hold special types of hardware. This property only has meaning when the corresponding Boolean SpecialPurpose property is set to TRUE.

SerialNumber

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

Manufacturer-allocated number used to identify the physical element.

This property is inherited from CIM_PhysicalElement.

SKU

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

Stock-keeping unit number for the physical element.

This property is inherited from CIM_PhysicalElement.

SpecialPurpose

Data type: boolean

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_Slot.PurposeDescription")

If TRUE, the slot is physically unique and may hold special types of hardware, (for example, a graphics processor slot). If TRUE, the PurposeDescription property should specify how the slot is unique or the slot's purpose.

Status

Data type: string

Access type: Read-only

Qualifiers: MaxLen (10), DisplayName ("Status")

Current status of the object. This property is inherited from CIM_ManagedSystemElement.

Values include the following:

OK ("OK")

Error ("Error")

Degraded ("Degraded")

Unknown ("Unknown")

Pred Fail ("Pred Fail")

Starting ("Starting")

Stopping ("Stopping")

Service ("Service")

Stressed ("Stressed")

NonRecover ("NonRecover")

No Contact ("No Contact")

Lost Comm ("Lost Comm")

SupportsHotPlug

Data type: boolean

Access type: Read-only

If TRUE, the slot supports hot-plugging of adapter cards.

Tag

Data type: string

Access type: Read-only

Qualifiers: CIM_Key, MaxLen (256)

Arbitrary string that uniquely identifies the physical element and serves as the element's key. This property can contain information, such as asset tag or serial number data. The key for CIM_PhysicalElement is placed very high in the object hierarchy to independently identify the hardware/entity, regardless of physical placement in (or on) cabinets, adapters, and so on. For example, a removable component that can be hot-swapped can be taken from its containing (scoping) package and be temporarily unused. The object still continues to exist and can even be inserted into a different scoping container. The key for a physical element is an arbitrary string that is defined independently of placement or location-oriented hierarchy.

This property is inherited from CIM_PhysicalElement.

ThermalRating

Data type: uint32

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|System Slot|004.11"), Units ("milliwatts")

Maximum thermal dissipation of the slot, in milliwatts.

VccMixedVoltageSupport

Data type: uint16 array

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|System Slot|004.9")

Vcc voltage supported by the slot.

Unknown (0)

Other (1)

3.3V (2)

5V (3)

Version

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

Version of the physical element.

This property is inherited from CIM_PhysicalElement.

VppMixedVoltageSupport

Data type: uint16 array

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|System Slot|004.10")

Vpp voltage supported by the slot.

Unknown (0)

Other (1)

3.3V (2)

5V (3)

12V (4)

Remarks

The CIM_Slot class is derived from CIM_PhysicalConnector.

WMI does not implement this class. For WMI classes derived from CIM_Slot, see Win32 Classes.

This documentation is derived from the CIM class descriptions published by the DMTF. Microsoft may have made changes to correct minor errors, conform to Microsoft SDK documentation standards, or provide more information.

Requirements

Requirement Value
Minimum supported client
Windows Vista
Minimum supported server
Windows Server 2008
Namespace
Root\CIMV2
MOF
CIMWin32.mof
DLL
CIMWin32.dll

See also

CIM_PhysicalConnector