Rediģēt

Kopīgot, izmantojot


Using a room control system (Surface Hub)

Room control systems can be used with your Microsoft Surface Hub. Using a room control system with your Surface Hub involves connecting room control hardware to the Surface Hub, usually through the RJ11 serial port on the bottom of the Surface Hub.

Terminal settings

To connect to a room control system control panel, you don't need to configure any terminal settings on the Surface Hub. If you want to connect a PC or laptop to your Surface Hub and send serial commands from the Surface Hub, you can use a terminal emulator program like Tera Term or PuTTY.

Setting Value
Baud rate 115200
Data bits 8
Stop bits 1
Parity none
Flow control none
Line feed every carriage return

Wiring diagram

You can use a standard RJ-11 (6P6C) connector to connect the Surface Hub serial port to a room control system. This method is the recommended method. You can also use an RJ-11 4-conductor cable, but we don't recommend this method.

This diagram shows the correct pinout used for an RJ-11 (6P6C) to DB9 cable.

Image showing the wiring diagram.

Command sets

Room control systems use common meeting-room scenarios for commands. Commands originate from the room control system, and are communicated over a serial connection to a Surface Hub. Commands are ASCII based, and the Surface Hub acknowledges when state changes occur.

The following command modifiers are available. Commands terminate with a new line character (\n). Responses can come at any time in response to state changes not triggered directly by a management port command.

Modifier Result
+ Increment a value
- Decrease a value
= Set a discrete value
? Queries for a current value

Power

Surface Hub can be in one of these power states.

State Energy Star state Description
0 S5 Off
1 - Power up (indeterminate)
2 S3 Sleep
5 S0 Ready

In Replacement PC mode, the power states are only Ready and Off and only change the display. The management port can't be used to power on the replacement PC.

State Energy Star state Description
0 S5 Off
5 S0 Ready

For a control device, anything other than 5 / Ready should be considered off. Each PowerOn command results in two state changes and responses.

Command State change Response
PowerOn Device turns on (display + PC).

PC service notifies SMC that the PC is ready.
Power=0

Power=5
PowerOff Device transitions to ambient state (PC on, display dim). Power=0
Power? SMC reports the last-known power state. Power=<#>

Brightness

The current brightness level is a range from 0 to 100.

A room control system, or other system, sends changes to brightness levels.

Command State change Response
Brightness+ System management controller (SMC) sends the brightness up command.

PC service on the room control system notifies SMC of new brightness level.
Brightness = 51
Brightness- SMC sends the brightness down command.

PC service notifies SMC of new brightness level.
Brightness = 50

Volume

The current volume level is a range from 0 to 100.

A room control system, or other system, sends changes to volume levels.

Note

The Volume command will only control the volume for embedded or Replacement PC mode, not from Guest sources.

Command State change Response
(On in Replacement PC mode)
Volume+ SMC sends the volume up command.

PC service notifies SMC of new volume level.
Volume = 51
Volume- SMC sends the volume down command.

PC service notifies SMC of new volume level.
Volume = 50

Mute for audio

Audio can be muted.

Command State change Response
AudioMute+ SMC sends the audio mute command.

PC service notifies SMC that audio is muted.
none

Video source

Several display sources can be used.

State Description
0 Onboard PC
1 DisplayPort
2 HDMI
3 VGA

Changes to display source can be sent by a room control system, or other system.

Command State change Response
Source=# SMC changes to the desired source.

PC service notifies SMC that the display source has switched.
Source=<#>
Source+ SMC cycles to the next active input source.

PC service notifies SMC of the current input source.
Source=<#>
Source- SMC cycles to the previous active input source.

PC service notifies SMC of the current input source.
Source=<#>
Source? SMC queries PC service for the active input source.

PC service notifies SMC of the current in; put source.
Source=<#>

Errors

Errors are returned following the format in this table.

Error Notes
Error: Unknown command '<input>'. The instruction contains an unknown initial command. For example, "VOL+" would be invalid and return " Error: Unknown command 'VOL'".
Error: Unknown operator '<input>'. The instruction contains an unknown operator. For example, "Volume!" would be invalid and return " Error: Unknown operator '!'".
Error: Unknown parameter '<input>'. The instruction contains an unknown parameter. For example, "Volume=abc" would be invalid and return " Error: Unknown parameter 'abc'".
Error: Command not available when off '<input>'. When the Surface Hub is off, commands other than Power return this error. For example, "Volume+" would be invalid and return " Error: Command not available when off 'Volume'".