Udostępnij za pośrednictwem


Partition Processing Destination Custom Properties

The Partition Processing destination has both custom properties and the properties common to all data flow components.

The following table describes the custom properties of the Partition Processing destination. All properties are read/write.

Property

Data Type

Description

ASConnectionString

String

The connection string to an Analysis Services project or an instance of Analysis Services.

KeyDuplicate

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates how to handle duplicate key errors. The possible values are IgnoreError (0), ReportAndContinue (1), and ReportAndStop (2). The default value of this property is IgnoreError (0).

KeyErrorAction

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates how to handle key errors. The possible values are ConvertToUnknown (0) and DiscardRecord (1). The default value of this property is ConvertToUnknown (0).

KeyErrorLimit

Integer

When UseDefaultConfiguration is False, the upper limit of key errors that are allowed.

KeyErrorLimitAction

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates the action to take when KeyErrorLimit is reached. The possible values are StopLogging (1) and StopProcessing (0). The default value of this property is StopProcessing (0).

KeyErrorLogFile

String

When UseDefaultConfiguration is False, the path and file name of the error log file.

KeyNotFound

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates how to handle missing key errors. The possible values are IgnoreError (0), ReportAndContinue (1), and ReportAndStop (2). The default value of this property is ReportAndContinue (1).

NullKeyConvertedToUnknown

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates how to handle null keys converted to the Unknown value. The possible values are IgnoreError (0), ReportAndContinue (1), and ReportAndStop (2). The default value of this property is IgnoreError (0).

NullKeyNotAllowed

Integer (enumeration)

When UseDefaultConfiguration is False, a value that indicates how to handle disallowed nulls. The possible values are IgnoreError (0), ReportAndContinue (1), and ReportAndStop (2). The default value of this property is ReportAndContinue (1).

ProcessType

Integer (enumeration)

The type of partition processing the transformation uses. The possible values are ProcessAdd (1) (incremental), ProcessFull (0), and ProcessUpdate (2).

UseDefaultConfiguration

Boolean

A value that specifies whether the transformation uses the default error configuration. If this property is False, the transformation uses the values of the error-handling custom properties listed in this table, including KeyDuplicate, KeyErrorAction, and so on.

The input and the input columns of the Partition Processing destination have no custom properties.

For more information, see Partition Processing Destination.

Zobacz także

Odwołanie

Common Properties