Compartilhar via


IContainerAppProbe Interface

Definition

[System.ComponentModel.TypeConverter(typeof(Microsoft.Azure.PowerShell.Cmdlets.App.Models.ContainerAppProbeTypeConverter))]
public interface IContainerAppProbe : Microsoft.Azure.PowerShell.Cmdlets.App.Runtime.IJsonSerializable
[<System.ComponentModel.TypeConverter(typeof(Microsoft.Azure.PowerShell.Cmdlets.App.Models.ContainerAppProbeTypeConverter))>]
type IContainerAppProbe = interface
    interface IJsonSerializable
Public Interface IContainerAppProbe
Implements IJsonSerializable
Derived
Attributes
Implements

Properties

FailureThreshold

Minimum consecutive failures for the probe to be considered failed after having succeeded. Defaults to 3. Minimum value is 1. Maximum value is 10.

HttpGetHost

Host name to connect to, defaults to the pod IP. You probably want to set "Host" in httpHeaders instead.

HttpGetHttpHeader

Custom headers to set in the request. HTTP allows repeated headers.

HttpGetPath

Path to access on the HTTP server.

HttpGetPort

Name or number of the port to access on the container. Number must be in the range 1 to 65535. Name must be an IANA_SVC_NAME.

HttpGetScheme

Scheme to use for connecting to the host. Defaults to HTTP.

InitialDelaySecond

Number of seconds after the container has started before liveness probes are initiated. Minimum value is 1. Maximum value is 60.

PeriodSecond

How often (in seconds) to perform the probe. Default to 10 seconds. Minimum value is 1. Maximum value is 240.

SuccessThreshold

Minimum consecutive successes for the probe to be considered successful after having failed. Defaults to 1. Must be 1 for liveness and startup. Minimum value is 1. Maximum value is 10.

TcpSocketHost

Optional: Host name to connect to, defaults to the pod IP.

TcpSocketPort

Number or name of the port to access on the container. Number must be in the range 1 to 65535. Name must be an IANA_SVC_NAME.

TerminationGracePeriodSecond

Optional duration in seconds the pod needs to terminate gracefully upon probe failure. The grace period is the duration in seconds after the processes running in the pod are sent a termination signal and the time when the processes are forcibly halted with a kill signal. Set this value longer than the expected cleanup time for your process. If this value is nil, the pod's terminationGracePeriodSeconds will be used. Otherwise, this value overrides the value provided by the pod spec. Value must be non-negative integer. The value zero indicates stop immediately via the kill signal (no opportunity to shut down). This is an alpha field and requires enabling ProbeTerminationGracePeriod feature gate. Maximum value is 3600 seconds (1 hour)

TimeoutSecond

Number of seconds after which the probe times out. Defaults to 1 second. Minimum value is 1. Maximum value is 240.

Type

The type of probe.

Methods

ToJson(JsonObject, SerializationMode) (Inherited from IJsonSerializable)

Applies to