SMS_TaskSequence_ApplyWindowsSettingsAction Server WMI Class
Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2
The SMS_TaskSequence_ApplyWindowsSettingsAction Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a task sequence action that applies Windows settings configuration information for the target computer.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Class SMS_TaskSequence_ApplyWindowsSettingsAction : SMS_TaskSequence_Action
{
String AdminPassword;
String ComputerName;
SMS_TaskSequence_Condition Condition;
Boolean ContinueOnError;
String Description;
Boolean Enabled;
String Name;
String ProductKey;
Boolean RandomAdminPassword;
String RegisteredOrgName;
String RegisteredUserName;
UInt32 ServerLicenseConnectionLimit;
String ServerLicenseMode;
String SupportedEnvironment;
UInt32 Timeout;
String TimeZone;
};
Methods
The SMS_TaskSequence_ApplyWindowsSettingsAction class does not define any methods.
Properties
AdminPassword
Data type: StringAccess type: Read/Write
Qualifiers: [VariableName("OSDLocalAdminPassword"), Secret, AllowedLen("0-255")]
Local administrator password. The name can be between 0 and 255 characters in length. This property must be set, but it is ignored if the RandomAdminPassword property is set to e.
The task sequence variable associated with this property is OSDLocalAdminPassword. For more information, see the MSDN documentation for Operating System Deployment Task Sequence Variables.
ComputerName
Data type: StringAccess type: Read/Write
Qualifiers: None
Name assigned to the target computer. The default name is "%_SMSTSMachineName%".
Condition
Data type: SMS_TaskSequence_ConditionAccess type: Read/Write
Qualifiers: None
ContinueOnError
Data type: BooleanAccess type: Read/Write
Qualifiers: None
Description
Data type: StringAccess type: Read/Write
Qualifiers: [AllowedLen("0-255")]
Enabled
Data type: BooleanAccess type: Read/Write
Qualifiers: None
Name
Data type: StringAccess type: Read/Write
Qualifiers: [AllowedLen("1-100")]
ProductKey
Data type: StringAccess type: Read/Write
Qualifiers: [QuasiSecret]
The product code for the new operating system.
RandomAdminPassword
Data type: BooleanAccess type: Read/Write
Qualifiers: [not_null]
true (default) to set the administrator password to a randomly generated value and disable the account in the operating system that is being deployed. The local administrator account, specified by AdminPassword, is disabled on the target computer. Set this property to false to enable the local administrator account and set the password as specified by the AdminPassword property. This property must be set.
RegisteredOrgName
Data type: StringAccess type: Read/Write
Qualifiers: [Not_Null, AllowedLen("1-255")]
Registered organization name in the new operating system. The name length can be between 1 and 255 characters. This property must be set.
RegisteredUserName
Data type: StringAccess type: Read/Write
Qualifiers: [Not_Null, AllowedLen("1-255")]
Registered user name in the new operating system. The name length can be between 1 and 255 characters. This property must be set.
ServerLicenseConnectionLimit
Data type: UInt32Access type: Read/Write
Qualifiers: [ValueRange("5-9999")]
Limit on server license connections. The value can be between 5 and 9999. Use this property to configure server licensing on Windows 2000 Server or Windows Server 2003.
ServerLicenseMode
Data type: StringAccess type: Read/Write
Qualifiers: None
The server licensing mode. Possible values for Windows 2000 Server and Windows Server 2003 are:
PerSeat
PerServer
SupportedEnvironment
Data type: StringAccess type: Read/Write
Qualifiers: [Not_Null:ToInstance]
See SMS_TaskSequence_Action Server WMI Class.
The default value of this property for this task sequence action is WinPE.
Timeout
Data type: UInt32Access type: Read/Write
Qualifiers: None
TimeZone
Data type: StringAccess type: Read/Write
Qualifiers: [Not_Null]
Time zone for the new operating system. This property must be set to an English language string. A non-English localized string causes the time zone setting to fail and default to Universal Coordinated Time (UTC).
Remarks
Class qualifiers for this class include:
[CommandLine("osdwinsettings.exe /config"),VariablePrefix("OSD"),
ActionCategory{"Settings,5,6"},ActionUI{"AdminUI.TaskSequenceEditor.dll", "Microsoft.ConfigurationManagement.AdminConsole.TaskSequenceEditor", "ApplyWindowsSettingsControl", "TaskSequenceOptionControl"}]
For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements
For more information, see Configuration Manager Server Development Requirements.
See Also
Concepts
Operating System Deployment Server WMI Classes
About Operating System Deployment Task Sequences
Configuration Manager Operating System Deployment
How to Create an Operating System Deployment Task Sequence
How to Add an Operating System Deployment Task Sequence Action