OID_DOT11_PBCC_OPTION_IMPLEMENTED (Compact 2013)
3/26/2014
When queried, this OID requests that the miniport driver return the value of the IEEE 802.11b dot11PBCCOptionImplemented management information base (MIB) object for the current PHY type on the 802.11 station.
The dot11PBCCOptionImplemented MIB object specifies whether the current PHY type supports enabled packet binary convolutional code (PBCC) modulation. For more information about PBCC modulation, refer to Clause 18.4.6.6 of the IEEE 802.11b‑1999 standard.
The data type for this OID is a BOOLEAN value. A value of TRUE indicates that the current PHY type supports PBCC modulation.
The dot11ERPPBCCOptionImplemented MIB object is valid only for the following PHY types:
- High-rate direct-sequence spread spectrum (HRDSS) PHY
- Extended-rate PHY (ERP)
If the current PHY type is not set to dot11_phy_type_hrdsss or dot11_phy_type_erp, the miniport driver must fail the query request by returning NDIS_STATUS_INVALID_DATA from its MiniportOidRequest function.
If the miniport driver is operating in Extensible Station (ExtSTA) mode, the current PHY type is determined through the ExtSTA msDot11CurrentPhyID MIB object. This MIB object specifies the index of the current PHY type within the 802.11 station’s list of supported PHY types. For more information about msDot11CurrentPhyID, see OID_DOT11_CURRENT_PHY_ID.
Requirements
Header |
windot11.h |
See Also
Reference
NDIS 5.x Legacy Wireless LAN OIDs
MiniportOidRequest
OID_DOT11_CURRENT_PHY_ID
NDIS 5.x Legacy Reference