Uredi

Deli z drugimi prek


Handle ingestion delay in scheduled analytics rules

While Microsoft Sentinel can ingest data from various sources, ingestion time for each data source may differ in different circumstances.

This article describes how ingestion delay might impact your scheduled analytics rules and how you can fix them to cover these gaps.

Why delay is significant

For example, you might write a custom detection rule, setting the Run query every and Lookup data from the last fields to have the rule run every five minutes, looking up data from those last five minutes:

Screenshot showing the Analytics Rule Wizard - Create new rule window.

The Lookup data from the last field defines a setting known as a look-back period. Ideally, when there's no delay, this detection misses no events, as shown in the following diagram:

Diagram showing a five-minute look-back window.

The event arrives as it's generated, and is included in the lookback period.

Now, assume there's some delay for your data source. For this example, let's say the event was ingested two minutes after it was generated. The delay is two minutes:

Diagram showing five-minute look back windows with a delay of two minutes.

The event is generated within the first look-back period, but isn't ingested in your Microsoft Sentinel workspace on the first run. The next time the scheduled query runs, it ingests the event, but the time-generated filter removes the event because it happened more than five minutes ago. In this case, the rule does not fire an alert.

How to handle delay

Note

You can either solve the issue using the process described below, or implement Microsoft Sentinel's near-real-time detection (NRT) rules. For more information, see Detect threats quickly with near-real-time (NRT) analytics rules in Microsoft Sentinel.

To solve the issue, you need to know the delay for your data type. For this example, you already know the delay is two minutes.

For your own data, you can understand delay using the Kusto ingestion_time() function, and calculating the difference between TimeGenerated and the ingestion time. For more information, see Calculate ingestion delay.

After determining the delay, you can address the problem as follows:

  • Increase the look-back period. Basic intuition tells you that increasing the look-back period size will help. Since your look-back period is five minutes and your delay is two minutes, setting the look-back period to seven minutes will help address this problem. For example, in your rule settings:

    Screenshot that shows setting the look-back window to seven minutes.

    The following diagram shows how the look-pack period now contains the missed event:

    Diagram that shows seven-minute look back windows with a delay of two minutes.

  • Handle duplication. Only increasing the look-back period can create duplication, because the look-back windows now overlap. For example, a different event may look as shown in the following diagram:

    Diagram showing how overlapping look-back windows create duplication.

    Since the event TimeGenerated value is found in both look-back periods, the event fires two alerts. You need to find a way to solve the duplication.

  • Associate the event to a specific look-back period. In the first example, you missed events because your data wasn't ingested when the scheduled query ran. You extended the look-back to include the event, but this caused duplication. You have to associate the event to the window you extended to contain it.

    Do this by setting ingestion_time() > ago(5m), instead of the original rule look-back = 5m. This setting associates the event to the first look-back window. For example:

    Diagram showing how setting the ago restriction avoids duplication.

    The ingestion time restriction now trims the extra two minutes you added to the look-back period. And for the first example, the second run look-back period now captures the event:

    Diagram showing how setting the ago restriction captures the event.

The following sample query summarizes the solution for solving ingestion delay issues:

let ingestion_delay = 2min;
let rule_look_back = 5min;
CommonSecurityLog
| where TimeGenerated >= ago(ingestion_delay + rule_look_back)
| where ingestion_time() > ago(rule_look_back)

Calculate ingestion delay

By default, Microsoft Sentinel scheduled alert rules are configured to have a 5-minute look-back period. However, each data source may have its own, individual ingestion delay. When joining multiple data types, you must understand the different delays for each data type in order to configure the look-back period correctly.

The Workspace Usage Report, provided in Microsoft Sentinel out-of-the-box, includes a dashboard that shows latency and delays for the different data types flowing into your workspace.

For example:

Screenshot of the Workspace Usage Report showing End to End Latency by table

Next steps

For more information, see: