Redigera

Dela via


MSSQLSERVER_5233

Applies to: SQL Server

Details

Attribute Value
Product Name SQL Server
Event ID 5233
Event Source MSSQLSERVER
Component SQLEngine
Symbolic Name DBCC4_INCORRECT_VALUE_IN_PAGE_HEADER_NO_METADATA
Message Text Table error: alloc unit ID A_ID, page P_ID. The test (TEST) failed. The values are VAL1 and VAL2.

Explanation

Page P_ID has failed auditing due to a corruption in its page header. The string in TEST gives the actual test that failed.

Look for Hardware Failure

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows system and application logs and the SQL Server error log to see whether the error occurred as the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware components to isolate the problem. Check to make sure that the system does not have write-caching enabled on the disk controller. If you suspect write-caching to be the problem, contact your hardware vendor.

Finally, you might find it useful to switch to a new hardware system. This switch may include reformatting the disk drives and reinstalling the operating system.

Restore from Backup

If the problem is not hardware related and a known clean backup is available, restore the database from the backup.

Run DBCC CHECKDB

Not applicable. This error cannot be repaired. If you cannot restore the database from a backup, contact Microsoft Customer Service and Support (CSS).