Known issues
Getting the latest Insider Preview build of the MSIX Packaging Tool
If you have opted in to our Insider Program, make sure you have the correct version of the MSIX Packaging Tool:
- Go to the About section in the MSIX Packaging Tool to view which version you are on.
- Go here to determine the latest Insider Preview version, and confirm you have that version of the MSIX Packaging Tool installed.
- Make sure the MSA that's signed up for flighting is the account that is signed into the Microsoft Store.
- Manually update the MSIX Packaging Tool through the Microsoft Store on your computer. If this option if available to you, open the Store, go to Downloads and updates, and click Get updates. Alternatively, search for the MSIX Packaging Tool, and on the product page you can then prompt it for an update.
- To install the MSIX Packaging Tool for offline use, follow these instructions to ensure you get the latest app through our offline process.
If you are interested in joining our Insider Program, go to Join MSIX Packaging Tool Insiders!.
MSIX Packaging Tool driver
The MSIX Packaging Tool driver is delivered as a Feature on Demand (FOD) package from Windows Update. It will fail to install if the Windows Update service is disabled on the computer or if Windows Insider flight ring settings do not match the OS build of the computer.
If you are running into problems acquiring the driver, or you are working in an offline environment, you can find links to download the driver here.
If you have downloaded the driver and are running into issues during your package conversion, it may be one of the following issues.
Network connectivity issues
The following error codes might indicate that you are encountering connection issues:
- -2145107924 (0x8024402c)
- -2145107945 (0x80244017)
- -2145123272 (0x80240438)
Windows Server Update Service (WSUS), Configuration Manager, or group policies affecting Windows Update connectivity
The following error code may indicate that policies on your computer are be affecting Windows Update connectivity: -2145124306 (0x8024002e).
If you receive this error code, you may need to check your environment settings and policies.
Driver required a reinstall
In this scenario, the MSIX Packaging Tool will notify you in the error message and logs that your driver needs a restart. Restart your computer and start your conversion again to fix this issue.
Error starting the MSIX packaging tool driver 0x80131500
If you get this error during the conversion, when you check the log file you should find an entry like the following one:
[Error] Error monitoring: Insufficient system resources exist to complete the requested service
This error happens when the tool starts a new system event tracing session, but you have exceeded the maximum number of sessions that Windows can create system-wide. If you exceed the default limit (64) you will hit an ERROR_NO_SYSTEM_RESOURCES error, which causes the driver to fail.
The solution is to stop some of the existing Event Trace sessions by following these steps:
- Open the Start menu and look for Performance Monitor.
- Right-click on it and choose More -> Run as Administrator.
- From the tree menu, choose Data Collector Sets -> Event Trace Sessions.
- Right-click on some of the existing sessions in the list and choose Stop.
Now you can try again performing the conversion with the MSIX Packaging Tool.
Minimum version
There are a few features to be aware of that automatically change the minimun version support in your MSIX Package.
Enforce Microsoft store versioning requirements
If you convert your existing installer using a version of the MSIX Packaging Tool earlier than 1.2019.701.0, the tool had Enforce Microsoft Store versioning requirements on, or used another tool to create your package that did not set the minimum version to 10.0.16299.0 (Windows 10, version 1709). This will cause an error message when deploying your app to Windows 10, version 1709 or a later version.
To fix this issue, open the MSIX Packaging Tool and edit your app through Package Editor. Open your manifest and set the MinVersion
attribute of the TargetDeviceFamily
element to "10.0.16299.0".
<Dependencies>
<TargetDeviceFamily> Name="Windows.Desktop" MinVersion="10.0.16299.0" MaxVersionTested = "10.0.17763.0" />
</Dependencies>
MSIX with services
In version 1.2019.1220.0 of the MSIX Packaging Tool, we added support for creating an MSIX package with Services. Due to the OS restrictions with services support, the MSIX Packaging Tool automatically changes the min version supported in an MSIX package with services to 10.0.19025.0. This means that you cannot install an MSIX with services on an OS lower than the Windows 10 version 2004, but you can create that MSIX using the MSIX Packaging Tool down to Windows 10 1809. If you need to install this app on a lower OS, update the min version appropriately but note that support for services will not work.
Frameworks and drivers
If the app requires a framework, make sure the framework is installed during the monitoring phase of the conversion. Go through the logs to ensure this is happening. If your app requires a driver to install, you need to evaluate whether this is required for your app to run properly. MSIX currently does not support driver installation.
Remote Machine
If you are running into issues with using a remote VM for your conversions, see Setup instructions for remote machine conversions.
Issues during conversion
- Some installers might fail to convert with exit code 259. This indicates that the installer spawned a thread and did not wait for it to complete. In other words, the main thread finished installing but it exited with error 259 because it spawned a thread that is still running. We recommend that you use the appropriate install option for setup.exe.
Issues during signing
Bad PE certificate (0x800700C1)
This problem occurs when the package contains a binary file that has a corrupt certificate. To resolve this issue, use the dumpbin.exe /headers
command to dump the file headers and inspect for bad elements. Manually rewrite the headers to fix the issue. In general, the MSIX Packaging tool automatically detects bad headers. If this issue persists, file feedback. More information can be found here.
Device Guard signing
Make sure to follow these steps and that you are assigning the appropriate roles in the Microsoft Store for Business.
Expired certificate
- Use a timestamp when you sign your package.
- You can resign with a valid sign or timestamp certificate.
You can resign your app using the batch conversion script at MSIX Toolkit - Scripts.
Troubleshooting
Log files
Whether or not your conversion was successful, log files are generated for every conversion. They can be found here:
%localappdata%\packages\Microsoft.MsixPackagingTool_8wekyb3d8bbwe\LocalState\DiagOutputDir\
Failure codes are written and indicate any point of failure during the conversion process. The error codes are meant to be user friendly.
Log files from remote devices or VMs
If the conversion is performed on a remote device or a VM, we recommend that you copy the log files from that device and attach them as part of the feedback item. This will help us diagnose and resolve issues more efficiently.
You will find the logs from the remote conversions here:
%localappdata%\packages\Microsoft.MsixPackagingTool_8wekyb3d8bbwe\LocalState\DiagOutputDir\<Logs_#>\RemoteServer\Log.txt
It would even more beneficial if you can share the whole Logs folder that will include the operations occurring on the local client as well the remote server.
Common problems
MakePri/Manifest translation errors
This error occurs when there is an issue with the package’s manifest. To identify the issue, go to Package Editor and open the manifest. When you open the manifest, you can identify the issue and provide the proper fix.
File not found
The file may either be open or non-existent. To resolve this issue, add the appropriate file or close the file that is currently in use. Note that you will not get a File not Found
error if it is open. Instead, you’ll get an Access Denied
or File in Use
error.
File Type Associations
The issues regarding File Type Associations (FTA) vary from package to package. MSIX Packaging Tool support file associations for double click installs. For example, if your app has context menu, it is not automatically added, so you will need to add it manually to the manifest. See the desktop4:FileExplorerContextMenus manifest element for an example.
Shortcuts with arguments
MSIX Packaging tool will capture all the user level shortcuts along with arguments. In case these shortcuts are not detected properly, you can add it manually to the manifest. See desktop7:Shortcut for more details.
Install directory
This is more common for those who use a secondary drive to perform app conversions. If you choose to change the installation location, it changes the root of where all of the files go. This means that the MSIX Packaging tool will need to know where all these files go and will be captured during conversion.
You can fix this by using the Package Support Framework write to install directory fix. We have added this as a capability by default in the MSIX Tool, which allows this down to 1809. If your application isn't working in 1709 and is in 1809, this is likely the issue.
Sending feedback
The best way to send your feedback is through the Feedback Hub.
- Open Feedback Hub or type Windows + F.
- Provide a title and necessary steps to reproduce the issue.
- Under Category, select Apps and select MSIX Packaging Tool.
- Attach any log files associated to the conversion. You can find the logs in the folder provided above.
- Attach the converted MSIX package (if possible).
- Click Submit.
You can also send us feedback directly from the MSIX Packaging Tool by going to the Feedback tab under Settings.