Describes WMI SNMP provider errors 1011 through 1020.

Fatal Error 1011

Fatal Error 1012

Fatal Error 1013

Warning 1014

Fatal Error 1015

Fatal Error 1016

Fatal Error 1018

Fatal Error 1020

Fatal Error 1011

<1011, Fatal>: "<fileName>:<line#> the SYNTAX of member <identifier> of SEQUENCE, <identifier>, differs from the SYNTAX clause of the OBJECT-TYPE"

OBJECT-TYPE macro invocation module semantic error. An element of a SEQUENCE must be same as the type in the SYNTAX clause of the OBJECT-TYPE definition. The <line#> parameter is the line of the SYNTAX clause of the OBJECT-TYPE definition.

This error can occur in either SNMPv1 or SNMPv2C.

Fatal Error 1012

<1012, Fatal>: "<fileName>:<line#> An INDEX or AUGMENTS clause is required only for SEQUENCE OBJECT-TYPES"

OBJECT-TYPE macro invocation module semantic error. An INDEX clause must only be present in an OBJECT-TYPE definition whose SYNTAX resolves to a SEQUENCE type.

This error can occur when compiling either an SNMPv1 or SNMPv2C MIB.

Fatal Error 1013

<1013, Fatal>: "<fileName><line#>: <identifier> should resolve to a SEQUENCE type"

OBJECT-TYPE macro invocation module semantic error. A type used in the "SEQUENCE OF" construct must resolve to a SEQUENCE type.

This error can occur in either SNMPv1 or SNMPv2C.

Warning 1014

<1014, Warning>: "<fileName>:<line#>: Sub-identifier of value 0 not recommended in OIDs"

OBJECT-TYPE macro invocation module semantic warning. It is recommended that no object in an Internet Standard MIB use a sub-identifier of zero in its OBJECT IDENTIFIER.

This warning can occur in either SNMPv1 or SNMPv2C.

Fatal Error 1015

<1015, Fatal>: "<fileName>:<line#>: OBJECT-TYPEs <identifier> from module <identifier> and <identifier> from module <identifier> are assigned the same OID values"

OBJECT-TYPE macro invocation module semantic error. Two OBJECT-TYPE invocations (in the same or different modules) must not be assigned the same Object Identifier value.

This error can occur in either SNMPv1 or SNMPv2C.

Fatal Error 1016

<1016, Fatal>: "<fileName>:<line#>: Value in the DEFVAL clause does not match the type in the SYNTAX clause"

OBJECT-TYPE macro invocation module semantic error. A value in a DEFVAL clause must be a value of the type mentioned in the SYNTAX clause.

This error can occur in either SNMPv1 or SNMPv2C.

Fatal Error 1018

<1018, Fatal>: "<fileName><line#>: <symbol> in ENTERPRISE clause of TRAP-TYPE does not resolve to an OID value"

TRAP-TYPE macro invocation, SNMPv1-specific module semantic error. The symbol used in the ENTERPRISE clause of a TRAP-TYPE macro invocation must resolve to an Object Identifier value.

Fatal Error 1020

<1020, Fatal>: "<fileName><line#>: Value assigned to TRAP-TYPE <identifier> does not resolve to a positive integer"