Azure Modular Data Center 2108 OEM release notes

This article contains release and version information for Azure Modular Data Center.

Overview

This document describes the contents of Azure Modular Data Center first party updates for firmware and drivers. This update includes improvements and fixes for the latest release of Azure Modular Data Center. Below are the download links:

Baseline and document history

Release Date Description of changes
2008 10/13/2020 2.2.2010.5 OEM package updates
2102 04/07/2021 2.2.2102.16 OEM package updates
2108 09/28/2021 2.2.2108.8 OEM package updates

Azure Stack Hub node

Boot Drive Controller - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 2.5.13.3024 Initial solution version
Release version Driver version Changes
2108, 2102, 2008 1.2.0.1051 Initial solution version

Capacity Drive Controller - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 16.17.01.00 Initial solution version
Release version Driver version Changes
2108, 2102, 2008 2.51.25.02 Initial solution version

Chipset - Azure Stack Hub

Release version Driver version Changes
2108, 2102, 2008 10.1.9.2 Initial solution version

Dell uEFI Diagnostics - Azure Stack Hub

Release version Application version Changes
2108, 2102, 2008 4301A38 Initial solution version

GPU - AMD MI25 Plus - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 3.04/D0513400 Initial solution version

iDRAC - Azure Stack Hub

Release version Firmware version Changes
2108 4.40.10.00 Fixes:
- Fixed drive re-inventory problem when upgrading PERC firmware following warm boot (152057)
- Fixed an iDRAC unresponsive issue when webserver is disabled (187318)
- Fixed a PSU mismatch reporting issue on C6525 (185201)
- Fixed an issue using custom webserver ports (185650)
- Fixed redfish connection issue (186497)

Enhancements:
- Support side band management for A100 GPU card

Micron 5100 M.2 480GB & 960GB - Azure Stack Hub

Release version Firmware version Changes
2108 E013 Fixes:
- Remove monitoring of 12V power bus, to improve drive stability in noisy 12V power conditions.
- Improve wear leveling algorithms, to recover cleanly from power cycles and manage high write workloads better.
- Fix to R_ERR handling, to eliminate case where high frequency of CRC errors may cause the drive to enter bus hang state.

Micron 5300 - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 D3MS402 Initial solution version

NIC - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 14.27.60.08 Initial solution version
Release version Driver version Changes
2108, 2102, 2008 2.40.22511.0 Initial solution version

PowerEdge R840 BIOS - Azure Stack Hub

Release version BIOS version Changes
2102 2.9.4 - Updated the "Processor and Memory Reference Code" for the second-generation Intel Xeon Processor Scalable Family to IPU 2020.2.

- Removed the Logical Processor requirement for Monitor/MWait.
2008 2.8.2 Initial solution version
2108 2.10.2 Fixes:
- Fixed an Intel errata reported on IPU 2020.1 and 2020.2 where the system could potentially not respond or reboot during POST when "Configuring Memory..." is displayed on the screen. This scenario may be encountered during system boot, where self-heal is attempted. The root cause is a race condition where during the self-heal process, a refresh cycle may not have completed when the CPU issues self-heal related commands to the DRAM.
The Issue is described in Intel Xeon Processor Scalable Family Specification Update, SKX120 and second-generation Intel Xeon Scalable Processors Specification Update, CLX51.

- Fixed an issue where an invalid location was specified for a self-heal request. This results in self-heal not being performed, which could potentially not respond or reboot the system during POST when "Configuring Memory..." is displayed on the screen.

Note: The Dell PowerEdge BIOS will automatically schedule DIMM self-healing during POST, based on DIMM health monitoring of correctable and uncorrectable errors from previous system boots.

- Updated Intel processor microcode to address the following issues:
* High Levels of Posted Interrupt Traffic on The PCIe Port May Result in a Machine Check with a TOR Timeout. The Issue is described in the Intel Xeon Processor Scalable Family Specification Update, SKX123 and Second-generation Intel Xeon Scalable Processors Specification Update, CLX52.
* Some Short Loops of Instructions May Cause a 3-Strike Machine Check without a TOR Timeout. The Issue is described in the Second-generation Intel Xeon Scalable Processors Specification Update, CLX53.

Enhancements:
- Updated the Processor Microcode to version 0x3005 for the second-generation Intel Xeon Processor Scalable Family.
- Updated the Processor Microcode to version 0x6A09 for the Intel Xeon Processor Scalable Family.

PowerEdge R840 CPLD - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 1.0.6 Initial solution version

Storage Backplane - Azure Stack Hub

Release version Firmware version Changes
2108, 2102, 2008 4.35 Initial solution version

Storage Backplane Expander - Azure Stack Hub

Release version Firmware version Changes
2008 2.46 Initial solution version
2108, 2102 2.52 - Addressed an issue with select 3rd party utilities where the LED Identify operation continues to blink after a planned drive replacement operation as completed.

- Addressed a firmware update issue when performed when no hard drives are present.

HLH

Boot Drive Controller - HLH

Release version Firmware version Changes
2108, 2102, 2008 2.5.13.3024 Initial solution version
Release version Driver version Changes
2108, 2102, 2008 1.2.0.1051 Initial solution version

Capacity Drive Controller - HLH

Release version Firmware version Changes
2008 25.5.7.0005 Initial solution version
2108, 2102 25.5.8.0001 - Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).
Release version Driver version Changes
2108, 2102, 2008 2.51.25.02 Initial solution version

Chipset - HLH

Release version Driver version Changes
2108, 2102, 2008 10.1.9.2 Initial solution version

Dell uEFI Diagnostics - HLH

Release version Application version Changes
2108, 2102, 2008 4301A38 Initial solution version

iDRAC - HLH

Release version Firmware version Changes
2108 4.40.10.00 Fixes:
- Fixed drive re-inventory problem when upgrading PERC firmware following warm boot (152057)
- Fixed an iDRAC unresponsive issue when webserver is disabled (187318)
- Fixed a PSU mismatch reporting issue on C6525 (185201)
- Fixed an issue using custom webserver ports (185650)
- Fixed redfish connection issue (186497)

Enhancements:
- Support side band management for A100 GPU card

Micron 5100 M.2 480GB & 960GB - HLH

Release version Firmware version Changes
2108 E013 Fixes:
- Remove monitoring of 12V power bus, to improve drive stability in noisy 12V power conditions.
- Improve wear leveling algorithms, to recover cleanly from power cycles and manage high write workloads better.
- Fix to R_ERR handling, to eliminate case where high frequency of CRC errors may cause the drive to enter bus hang state.

NIC - HLH

Release version Firmware version Changes
2102, 2008 19.5.12 Initial solution version
2108 20.0.17 - Intel(R) Ethernet 700 Series based adapters are subject to the content of Intel Technical Advisory TA_00380. Please review INTEL_TA_00380 for more detail.

- Resolved an issue where port link status in iDRAC for Intel(R) Ethernet 10G 2P X710 OCP adapter or Intel(R) Ethernet 10G 4P X710 OCP adapter may still appear as up after cable is disconnected.

- Resolved an issue where some X710 based adapters may display the Dell Family Firmware Version (FFV) instead of the OS driver version when viewing the device driver version in iDRAC.
Release version Driver version Changes
2102, 2008 1.11.101.0 Initial solution version
2108 1.13.104.0 - Resolved an issue on Windows OSs where using "Identify Adapter" under X710 based adapters' Adapter Properties in Device Manager does not blink the adapter LEDs.

PowerEdge R640 BIOS - HLH

Release version BIOS version Changes
2102 2.10.0 - Increased the 64bit Memory Mapped I/O allocation size, used for PCIe resource management, from 64GB to 256GB per root port to support Nvidia A100 GPU and other PCIe cards that request > 64GB of 64bit PCIe memory.

- Updated the "Processor and Memory Reference Code" for the second-generation Intel Xeon Processor Scalable Family to IPU 2020.2.

- Removed the Logical Processor requirement for Monitor/MWait.
2008 2.8.2 Initial solution version
2108 2.10.2 Fixes:
- Fixed an Intel errata reported on IPU 2020.1 and 2020.2 where the system could potentially not respond or reboot during POST when "Configuring Memory..." is displayed on the screen. This scenario may be encountered during system boot, where self-heal is attempted. The root cause is a race condition where during the self-heal process, a refresh cycle may not have completed when the CPU issues self-heal related commands to the DRAM.
The Issue is described in Intel Xeon Processor Scalable Family Specification Update, SKX120 and second-generation Intel Xeon Scalable Processors Specification Update, CLX51.

- Fixed an issue where an invalid location was specified for a self-heal request. This results in self-heal not being performed, which could potentially not respond or reboot the system during POST when "Configuring Memory..." is displayed on the screen.

Note: The Dell PowerEdge BIOS will automatically schedule DIMM self-healing during POST, based on DIMM health monitoring of correctable and uncorrectable errors from previous system boots.

- Updated Intel processor microcode to address the following issues:
* High Levels of Posted Interrupt Traffic on The PCIe Port May Result in a Machine Check with a TOR Timeout. The Issue is described in the Intel Xeon Processor Scalable Family Specification Update, SKX123 and Second-generation Intel Xeon Scalable Processors Specification Update, CLX52.
* Some Short Loops of Instructions May Cause a 3-Strike Machine Check without a TOR Timeout. The Issue is described in the Second-generation Intel Xeon Scalable Processors Specification Update, CLX53.

Enhancements:
- Updated the Processor Microcode to version 0x3005 for the second-generation Intel Xeon Processor Scalable Family.
- Updated the Processor Microcode to version 0x6A09 for the Intel Xeon Processor Scalable Family.

PowerEdge R640 CPLD - HLH

Release version Firmware version Changes
2102, 2008 9.0.6 Initial solution version
2108 1.0.6 Fixes:
-Addresses a possibility of IDRAC not responding during PSU firmware update.

Storage Backplane - HLH

Release version Firmware version Changes
2108, 2102, 2008 4.35 Initial solution version

Storage Backplane Expander - HLH

Release version Firmware version Changes
2008 2.46 Initial solution version
2108, 2102 2.52 - Addressed an issue with select 3rd party utilities where the LED Identify operation continues to blink after a planned drive replacement operation as completed.

- Addressed a firmware update issue when performed when no hard drives are present.

Infrastructure

Avocent MPU4032DAC KVM

Release version KVM FW version Changes
2008 2.6.0.25542 Initial solution version
2108, 2102 2.8.3.25691 - Improved product security

Geist N30030L PDU

Release version PDU FW version Changes
2008 i03-5_6_1-07092020 Initial solution version
2108, 2102 i03-5_7_0-11112020 - Several new features via ssh and API including ability to manage TLS certs.

- Fixes related to incorrect uptime, SNMP values freezing, and phase balance sum.

Storage

Isilon Drive

Release version Firmware version Changes
2108, 2102, 2008 1.33 Initial solution version

Isilon IA2000-E-10T-400G

Release version OS Patch version Changes
2008 8.2.2_GA-RUP_2020-07_PSP-40 Initial solution version
2108, 2102 9.1.0.3_GA-RUP_2021-01_PSP-664 - Most recent rollup package to go with 9.1 (January 2021). This patch addresses multiple Userspace and Kernel issues.
Release version OS version Changes
2008 8.2.2.0 Initial solution version
2108, 2102 9.1.0.0 Initial solution version

Isilon Node

Release version Firmware version Changes
2108, 2102, 2008 10.3.3 Initial solution version

Switches

CISCO BMC - Cisco NX-OS

Release version Firmware version Changes
2008 9.3.3 Initial solution version
2108, 2102 9.3.6 Latest recommended Cisco security and bug fixes as of November 2020.

CISCO TOR - Cisco NX-OS

Release version Firmware version Changes
2008 9.3.3 Initial solution version
2108, 2102 9.3.6 Latest recommended Cisco security and bug fixes as of November 2020.

Firewall - Cisco Firepower 4115 ASA

Release version Application version Changes
2102 9.12.4.10 Latest recommended Cisco security and bug fixes as of December 2020.
2008 9.12.2.9 Initial solution version
2108 9.12.4.18 Latest recommended Cisco security and bug fixes as of April 2021.

Firewall - Cisco Firepower 4115 FX-OS

Release version Firmware version Changes
2102 9.2.6.1.214 Updated to match recommended ASA SW version (9.12.4.10)
2008 9.2.6.1.187 Initial solution version
2108 9.2.6.1.224 Latest recommended Cisco security and bug fixes as of April 2021.

Storage Backend - Dell S4148F Switch

Release version Firmware version Changes
2108, 2102, 2008 10.5.0.6.685 Initial solution version