Comparteix a través de


MetricsBuilderExtensions.DisableMetrics Método

Definición

Sobrecargas

DisableMetrics(IMetricsBuilder, String)

Deshabilita todos los instrumentos para el medidor determinado, para todos los IMetricsListeners registrados.

DisableMetrics(MetricsOptions, String)

Deshabilita todos los instrumentos para el medidor determinado, para todos los IMetricsListeners registrados.

DisableMetrics(IMetricsBuilder, String, String, String, MeterScope)

Deshabilita un objeto especificado Instrument para los especificados Meter y IMetricsListener.

DisableMetrics(MetricsOptions, String, String, String, MeterScope)

Deshabilita un objeto especificado Instrument para los especificados Meter y IMetricsListener.

DisableMetrics(IMetricsBuilder, String)

Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs

Deshabilita todos los instrumentos para el medidor determinado, para todos los IMetricsListeners registrados.

public:
[System::Runtime::CompilerServices::Extension]
 static Microsoft::Extensions::Diagnostics::Metrics::IMetricsBuilder ^ DisableMetrics(Microsoft::Extensions::Diagnostics::Metrics::IMetricsBuilder ^ builder, System::String ^ meterName);
public static Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder DisableMetrics (this Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder builder, string? meterName);
static member DisableMetrics : Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder * string -> Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder
<Extension()>
Public Function DisableMetrics (builder As IMetricsBuilder, meterName As String) As IMetricsBuilder

Parámetros

builder
IMetricsBuilder

El parámetro de cadena de consulta IMetricsBuilder.

meterName
String

Prefijo Name o . Un valor NULL coincide con todos los medidores.

Devoluciones

Original IMetricsBuilder para encadenar.

Se aplica a

DisableMetrics(MetricsOptions, String)

Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs

Deshabilita todos los instrumentos para el medidor determinado, para todos los IMetricsListeners registrados.

public:
[System::Runtime::CompilerServices::Extension]
 static Microsoft::Extensions::Diagnostics::Metrics::MetricsOptions ^ DisableMetrics(Microsoft::Extensions::Diagnostics::Metrics::MetricsOptions ^ options, System::String ^ meterName);
public static Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions DisableMetrics (this Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions options, string? meterName);
static member DisableMetrics : Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions * string -> Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions
<Extension()>
Public Function DisableMetrics (options As MetricsOptions, meterName As String) As MetricsOptions

Parámetros

options
MetricsOptions

El parámetro de cadena de consulta MetricsOptions.

meterName
String

Prefijo Name o . Un valor NULL coincide con todos los medidores.

Devoluciones

Original MetricsOptions para encadenar.

Se aplica a

DisableMetrics(IMetricsBuilder, String, String, String, MeterScope)

Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs

Deshabilita un objeto especificado Instrument para los especificados Meter y IMetricsListener.

public static Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder DisableMetrics (this Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder builder, string? meterName, string? instrumentName = default, string? listenerName = default, Microsoft.Extensions.Diagnostics.Metrics.MeterScope scopes = Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Global | Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Local);
static member DisableMetrics : Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder * string * string * string * Microsoft.Extensions.Diagnostics.Metrics.MeterScope -> Microsoft.Extensions.Diagnostics.Metrics.IMetricsBuilder
<Extension()>
Public Function DisableMetrics (builder As IMetricsBuilder, meterName As String, Optional instrumentName As String = Nothing, Optional listenerName As String = Nothing, Optional scopes As MeterScope = Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Global | Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Local) As IMetricsBuilder

Parámetros

builder
IMetricsBuilder

El parámetro de cadena de consulta IMetricsBuilder.

meterName
String

Prefijo Name o . Un valor NULL coincide con todos los medidores.

instrumentName
String

El parámetro de cadena de consulta Name. Un valor NULL coincide con todos los instrumentos.

listenerName
String

. IMetricsListener Nombre. Un valor NULL coincide con todos los agentes de escucha.

scopes
MeterScope

Indica qué MeterScopese debe tener en cuenta. El valor predeterminado es todos los ámbitos.

Devoluciones

Original IMetricsBuilder para encadenar.

Se aplica a

DisableMetrics(MetricsOptions, String, String, String, MeterScope)

Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs
Source:
MetricsBuilderExtensions.Rules.cs

Deshabilita un objeto especificado Instrument para los especificados Meter y IMetricsListener.

public static Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions DisableMetrics (this Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions options, string? meterName, string? instrumentName = default, string? listenerName = default, Microsoft.Extensions.Diagnostics.Metrics.MeterScope scopes = Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Global | Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Local);
static member DisableMetrics : Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions * string * string * string * Microsoft.Extensions.Diagnostics.Metrics.MeterScope -> Microsoft.Extensions.Diagnostics.Metrics.MetricsOptions
<Extension()>
Public Function DisableMetrics (options As MetricsOptions, meterName As String, Optional instrumentName As String = Nothing, Optional listenerName As String = Nothing, Optional scopes As MeterScope = Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Global | Microsoft.Extensions.Diagnostics.Metrics.MeterScope.Local) As MetricsOptions

Parámetros

options
MetricsOptions

El parámetro de cadena de consulta MeterOptions.

meterName
String

Prefijo Name o . Un valor NULL coincide con todos los medidores.

instrumentName
String

El parámetro de cadena de consulta Name. Un valor NULL coincide con todos los instrumentos.

listenerName
String

. IMetricsListener Nombre. Un valor NULL coincide con todos los agentes de escucha.

scopes
MeterScope

Indica qué MeterScopese debe tener en cuenta. El valor predeterminado es todos los ámbitos.

Devoluciones

Original MeterOptions para encadenar.

Se aplica a