ToolZone.HeaderCloseVerb Properti
Definisi
Penting
Beberapa informasi terkait produk prarilis yang dapat diubah secara signifikan sebelum dirilis. Microsoft tidak memberikan jaminan, tersirat maupun tersurat, sehubungan dengan informasi yang diberikan di sini.
Mendapatkan referensi ke WebPartVerb objek di header ToolZone kontrol yang digunakan untuk menutup kontrol.
public:
virtual property System::Web::UI::WebControls::WebParts::WebPartVerb ^ HeaderCloseVerb { System::Web::UI::WebControls::WebParts::WebPartVerb ^ get(); };
[System.Web.UI.PersistenceMode(System.Web.UI.PersistenceMode.InnerProperty)]
public virtual System.Web.UI.WebControls.WebParts.WebPartVerb HeaderCloseVerb { get; }
[<System.Web.UI.PersistenceMode(System.Web.UI.PersistenceMode.InnerProperty)>]
member this.HeaderCloseVerb : System.Web.UI.WebControls.WebParts.WebPartVerb
Public Overridable ReadOnly Property HeaderCloseVerb As WebPartVerb
Nilai Properti
yang WebPartVerb digunakan untuk menutup ToolZone kontrol.
- Atribut
Contoh
Contoh kode berikut menunjukkan cara menggunakan HeaderCloseVerb properti dengan kontrol yang diwariskan ToolZone . Contoh menunjukkan cara mengaktifkan dan menonaktifkan kata kerja tutup di header EditorZone kontrol.
Bagian pertama dari contoh kode adalah kontrol pengguna yang dirujuk di halaman, dan memungkinkan Anda untuk mengalihkan halaman ke mode tampilan yang berbeda. Untuk informasi selengkapnya tentang mode tampilan dan memungkinkan pengguna beralih di antara mereka, lihat Panduan: Mengubah Mode Tampilan pada Halaman Bagian Web.
<%@ control language="C#" classname="DisplayModeMenuCS"%>
<script runat="server">
// Use a field to reference the current WebPartManager.
WebPartManager _manager;
void Page_Init(object sender, EventArgs e)
{
Page.InitComplete += new EventHandler(InitComplete);
}
void InitComplete(object sender, System.EventArgs e)
{
_manager = WebPartManager.GetCurrentWebPartManager(Page);
String browseModeName = WebPartManager.BrowseDisplayMode.Name;
// Fill the dropdown with the names of supported display modes.
foreach (WebPartDisplayMode mode in _manager.SupportedDisplayModes)
{
String modeName = mode.Name;
// Make sure a mode is enabled before adding it.
if (mode.IsEnabled(_manager))
{
ListItem item = new ListItem(modeName, modeName);
DisplayModeDropdown.Items.Add(item);
}
}
// If shared scope is allowed for this user, display the scope-switching
// UI and select the appropriate radio button for the current user scope.
if (_manager.Personalization.CanEnterSharedScope)
{
Panel2.Visible = true;
if (_manager.Personalization.Scope == PersonalizationScope.User)
RadioButton1.Checked = true;
else
RadioButton2.Checked = true;
}
}
// Change the page to the selected display mode.
void DisplayModeDropdown_SelectedIndexChanged(object sender, EventArgs e)
{
String selectedMode = DisplayModeDropdown.SelectedValue;
WebPartDisplayMode mode = _manager.SupportedDisplayModes[selectedMode];
if (mode != null)
_manager.DisplayMode = mode;
}
// Set the selected item equal to the current display mode.
void Page_PreRender(object sender, EventArgs e)
{
ListItemCollection items = DisplayModeDropdown.Items;
int selectedIndex =
items.IndexOf(items.FindByText(_manager.DisplayMode.Name));
DisplayModeDropdown.SelectedIndex = selectedIndex;
}
// Reset all of a user's personalization data for the page.
protected void LinkButton1_Click(object sender, EventArgs e)
{
_manager.Personalization.ResetPersonalizationState();
}
// If not in User personalization scope, toggle into it.
protected void RadioButton1_CheckedChanged(object sender, EventArgs e)
{
if (_manager.Personalization.Scope == PersonalizationScope.Shared)
_manager.Personalization.ToggleScope();
}
// If not in Shared scope, and if user is allowed, toggle the scope.
protected void RadioButton2_CheckedChanged(object sender, EventArgs e)
{
if (_manager.Personalization.CanEnterSharedScope &&
_manager.Personalization.Scope == PersonalizationScope.User)
_manager.Personalization.ToggleScope();
}
</script>
<div>
<asp:Panel ID="Panel1" runat="server"
Borderwidth="1"
Width="230"
BackColor="lightgray"
Font-Names="Verdana, Arial, Sans Serif" >
<asp:Label ID="Label1" runat="server"
Text=" Display Mode"
Font-Bold="true"
Font-Size="8"
Width="120"
AssociatedControlID="DisplayModeDropdown"/>
<asp:DropDownList ID="DisplayModeDropdown" runat="server"
AutoPostBack="true"
Width="120"
OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
<asp:LinkButton ID="LinkButton1" runat="server"
Text="Reset User State"
ToolTip="Reset the current user's personalization data for the page."
Font-Size="8"
OnClick="LinkButton1_Click" />
<asp:Panel ID="Panel2" runat="server"
GroupingText="Personalization Scope"
Font-Bold="true"
Font-Size="8"
Visible="false" >
<asp:RadioButton ID="RadioButton1" runat="server"
Text="User"
AutoPostBack="true"
GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
<asp:RadioButton ID="RadioButton2" runat="server"
Text="Shared"
AutoPostBack="true"
GroupName="Scope"
OnCheckedChanged="RadioButton2_CheckedChanged" />
</asp:Panel>
</asp:Panel>
</div>
<%@ control language="vb" classname="DisplayModeMenuVB"%>
<script runat="server">
' Use a field to reference the current WebPartManager.
Dim _manager As WebPartManager
Sub Page_Init(ByVal sender As Object, ByVal e As EventArgs)
AddHandler Page.InitComplete, AddressOf InitComplete
End Sub
Sub InitComplete(ByVal sender As Object, ByVal e As System.EventArgs)
_manager = WebPartManager.GetCurrentWebPartManager(Page)
Dim browseModeName As String = WebPartManager.BrowseDisplayMode.Name
' Fill the dropdown with the names of supported display modes.
Dim mode As WebPartDisplayMode
For Each mode In _manager.SupportedDisplayModes
Dim modeName As String = mode.Name
' Make sure a mode is enabled before adding it.
If mode.IsEnabled(_manager) Then
Dim item As New ListItem(modeName, modeName)
DisplayModeDropdown.Items.Add(item)
End If
Next mode
' If shared scope is allowed for this user, display the scope-switching
' UI and select the appropriate radio button for the current user scope.
If _manager.Personalization.CanEnterSharedScope Then
Panel2.Visible = True
If _manager.Personalization.Scope = PersonalizationScope.User Then
RadioButton1.Checked = True
Else
RadioButton2.Checked = True
End If
End If
End Sub
' Change the page to the selected display mode.
Sub DisplayModeDropdown_SelectedIndexChanged(ByVal sender As Object, _
ByVal e As EventArgs)
Dim selectedMode As String = DisplayModeDropdown.SelectedValue
Dim mode As WebPartDisplayMode = _
_manager.SupportedDisplayModes(selectedMode)
If Not (mode Is Nothing) Then
_manager.DisplayMode = mode
End If
End Sub
' Set the selected item equal to the current display mode.
Sub Page_PreRender(ByVal sender As Object, ByVal e As EventArgs)
Dim items As ListItemCollection = DisplayModeDropdown.Items
Dim selectedIndex As Integer = _
items.IndexOf(items.FindByText(_manager.DisplayMode.Name))
DisplayModeDropdown.SelectedIndex = selectedIndex
End Sub
' Reset all of a user's personalization data for the page.
Protected Sub LinkButton1_Click(ByVal sender As Object, _
ByVal e As EventArgs)
_manager.Personalization.ResetPersonalizationState()
End Sub
' If not in User personalization scope, toggle into it.
Protected Sub RadioButton1_CheckedChanged(ByVal sender As Object, _
ByVal e As EventArgs)
If _manager.Personalization.Scope = PersonalizationScope.Shared Then
_manager.Personalization.ToggleScope()
End If
End Sub
' If not in Shared scope, and if user is allowed, toggle the scope.
Protected Sub RadioButton2_CheckedChanged(ByVal sender As Object, _
ByVal e As EventArgs)
If _manager.Personalization.CanEnterSharedScope AndAlso _
_manager.Personalization.Scope = PersonalizationScope.User Then
_manager.Personalization.ToggleScope()
End If
End Sub
</script>
<div>
<asp:Panel ID="Panel1" runat="server"
Borderwidth="1"
Width="230"
BackColor="lightgray"
Font-Names="Verdana, Arial, Sans Serif" >
<asp:Label ID="Label1" runat="server"
Text=" Display Mode"
Font-Bold="true"
Font-Size="8"
Width="120"
AssociatedControlID="DisplayModeDropdown"/>
<asp:DropDownList ID="DisplayModeDropdown" runat="server"
AutoPostBack="true"
Width="120"
OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
<asp:LinkButton ID="LinkButton1" runat="server"
Text="Reset User State"
ToolTip="Reset the current user's personalization data for the page."
Font-Size="8"
OnClick="LinkButton1_Click" />
<asp:Panel ID="Panel2" runat="server"
GroupingText="Personalization Scope"
Font-Bold="true"
Font-Size="8"
Visible="false" >
<asp:RadioButton ID="RadioButton1" runat="server"
Text="User"
AutoPostBack="true"
GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
<asp:RadioButton ID="RadioButton2" runat="server"
Text="Shared"
AutoPostBack="true"
GroupName="Scope"
OnCheckedChanged="RadioButton2_CheckedChanged" />
</asp:Panel>
</asp:Panel>
</div>
Bagian kedua dari contoh kode adalah halaman Web. Halaman berisi EditorZone kontrol, yang mewarisi dari ToolZone kelas . Metode Button1_Click
dalam halaman menetapkan HeaderCloseVerb nilai properti.
Perhatikan bahwa setelah halaman dimuat, Anda harus mengalihkan halaman ke mode edit untuk melihat efek kode yang menggunakan HeaderCloseVerb properti pada EditorZone kontrol. Saat Anda mengklik tombol Aktifkan/Nonaktifkan Tutup Kata Kerja , kata kerja di header zona harus diaktifkan dan dinonaktifkan secara bergantian.
<%@ Page Language="C#" %>
<%@ register TagPrefix="uc1"
TagName="DisplayModeMenuCS"
Src="DisplayModeMenuCS.ascx" %>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<script runat="server">
void Button1_Click(object sender, EventArgs e)
{
bool EnableClose = false;
if(!EditorZone1.HeaderCloseVerb.Enabled)
EnableClose = true;
EditorZone1.HeaderCloseVerb.Enabled = EnableClose;
}
</script>
<head runat="server">
<title>Tool Zone Example</title>
</head>
<body>
<form id="form1" runat="server">
<div>
<asp:WebPartManager ID="WebPartManager1" Runat="server" />
<uc1:DisplayModeMenuCS ID="DisplayModeMenu1" runat="server" />
<asp:WebPartZone ID="WebPartZone1" Runat="server" >
<ZoneTemplate>
<asp:BulletedList
ID="BulletedList1"
Runat="server"
DisplayMode="HyperLink"
Title="Favorite Links" >
<asp:ListItem Value="http://msdn.microsoft.com">MSDN</asp:ListItem>
<asp:ListItem Value="http://www.asp.net">ASP.NET</asp:ListItem>
<asp:ListItem Value="http://www.msn.com">MSN</asp:ListItem>
</asp:BulletedList>
</ZoneTemplate>
</asp:WebPartZone>
<asp:EditorZone
ID="EditorZone1"
Runat="server">
<HeaderCloseVerb Text="End Editing" />
<ZoneTemplate>
<asp:AppearanceEditorPart ID="AppearanceEditorPart1" Runat="server" />
<asp:LayoutEditorPart ID="LayoutEditorPart1" Runat="server" />
</ZoneTemplate>
</asp:EditorZone>
<asp:Button ID="Button1" Runat="server"
Text="Enable/Disable Close Verb"
OnClick="Button1_Click" />
</div>
</form>
</body>
</html>
<%@ Page Language="VB" %>
<%@ register TagPrefix="uc1"
TagName="DisplayModeMenuVB"
Src="DisplayModeMenuVB.ascx" %>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<script runat="server">
Sub Button1_Click(ByVal sender As Object, ByVal e As EventArgs)
Dim EnableClose as Boolean = false
If EditorZone1.HeaderCloseVerb.Enabled = False Then
EnableClose = True
End If
EditorZone1.HeaderCloseVerb.Enabled = EnableClose
End Sub
</script>
<head runat="server">
<title>Tool Zone Example</title>
</head>
<body>
<form id="form1" runat="server">
<div>
<asp:WebPartManager ID="WebPartManager1" Runat="server" />
<uc1:DisplayModeMenuVB ID="DisplayModeMenu1" runat="server" />
<asp:WebPartZone ID="WebPartZone1" Runat="server" >
<ZoneTemplate>
<asp:BulletedList
ID="BulletedList1"
Runat="server"
DisplayMode="HyperLink"
Title="Favorite Links" >
<asp:ListItem Value="http://msdn.microsoft.com">MSDN</asp:ListItem>
<asp:ListItem Value="http://www.asp.net">ASP.NET</asp:ListItem>
<asp:ListItem Value="http://www.msn.com">MSN</asp:ListItem>
</asp:BulletedList>
</ZoneTemplate>
</asp:WebPartZone>
<asp:EditorZone
ID="EditorZone1"
Runat="server">
<HeaderCloseVerb Text="End Editing" />
<ZoneTemplate>
<asp:AppearanceEditorPart ID="AppearanceEditorPart1" Runat="server" />
<asp:LayoutEditorPart ID="LayoutEditorPart1" Runat="server" />
</ZoneTemplate>
</asp:EditorZone>
<asp:Button ID="Button1" Runat="server"
Text="Enable/Disable Close Verb"
OnClick="Button1_Click" />
</div>
</form>
</body>
</html>
Keterangan
Anda dapat menggunakan HeaderCloseVerb properti secara terprogram atau dalam markup deklaratif halaman Web untuk menentukan berbagai atribut untuk kata kerja yang digunakan untuk menutup ToolZone kontrol.