Msvm_SyntheticMouse class
Represents a synthetic mouse device.
The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.
Syntax
[Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_SyntheticMouse : CIM_PointingDevice
{
string Caption = "Mouse";
string Description = "Microsoft Synthetic Mouse";
datetime InstallDate;
string Name = "Mouse";
uint16 OperationalStatus[] = 2;
string Status;
uint16 HealthState = 5;
uint16 EnabledState = 2;
string OtherEnabledState;
uint16 RequestedState = 12;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
string SystemCreationClassName = "Msvm_ComputerSystem";
string SystemName = "GUID";
boolean PowerManagementSupported;
uint16 PowerManagementCapabilities[];
uint16 Availability;
uint16 StatusInfo;
uint32 LastErrorCode;
string ErrorDescription;
boolean ErrorCleared;
uint64 PowerOnHours;
uint64 TotalPowerOnHours;
uint16 AdditionalAvailability[] = 6;
uint64 MaxQuiesceTime;
uint16 LocationIndicator = 4;
boolean IsLocked = False;
uint16 PointingType = 3;
uint8 NumberOfButtons = 5;
uint32 Resolution;
string ElementName = "Mouse";
string StatusDescriptions[] = "OK";
string CreationClassName = "Msvm_SyntheticMouse";
string DeviceID = "Microsoft:GUID";
string OtherIdentifyingInfo[];
string IdentifyingDescriptions[];
uint16 Handedness = 2;
boolean AbsoluteCoordinates = True;
sint32 HorizontalPosition;
sint32 VerticalPosition;
sint32 ScrollPosition;
};
Members
The Msvm_SyntheticMouse class has these types of members:
Methods
The Msvm_SyntheticMouse class has these methods.
Method | Description |
---|---|
ClickButton | Performs a mouse click of the specified button. This is equivalent to calling SetButtonState twice, first to press the button, and again to release it. |
EnableDevice | This method is not supported. |
GetButtonState | Gets the current button state (up or down) of a specified button. |
OnlineDevice | This method is not supported. |
QuiesceDevice | This method is not supported. |
RequestStateChange | Requests that the state of the element be changed to the value specified in the RequestedState parameter. This method is inherited from CIM_EnabledLogicalElement and returns 1 (Not Supported). |
Reset | This method is not supported. |
RestoreProperties | This method is not supported. |
SaveProperties | This method is not supported. |
SetAbsolutePosition | Sets the horizontal and vertical position of the mouse cursor. |
SetButtonState | Sets whether the specified mouse button is currently pressed. |
SetPowerState | This method is not supported. |
SetScrollPosition | Changes the z-coordinate of the wheel control of the mouse. Values written to this property are always relative coordinate offsets. |
Properties
The Msvm_SyntheticMouse class has these properties.
-
AbsoluteCoordinates
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the device operates on absolute coordinates. If not set, the device's coordinates are relative. This property is set to True.
-
-
AdditionalAvailability
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalDevice.Availability")
Any additional availability and status of the device, beyond that specified in the Availability property. The Availability property denotes the primary status and availability of the device. This property is inherited from CIM_LogicalDevice and it is always set to 6 (Not Applicable).
-
-
Availability
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_AssociatedPowerManagementService.PowerState", "CIM_ManagedSystemElement.OperationalStatus", "CIM_EnabledLogicalElement.EnabledState"), MappingStrings ("MIF.DMTF|Operational State|006.5", "MIB.IETF|HOST-RESOURCES-MIB.hrDeviceStatus", "MIF.DMTF|Host Device|001.5"), ModelCorrespondence ("CIM_LogicalDevice.AdditionalAvailability")
This property is inherited from CIM_LogicalDevice but it is not used.
-
-
Caption
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
A short textual description (one-line string) of the object. This property is inherited from CIM_ManagedElement and it is always set to "Mouse".
-
-
CreationClassName
-
The name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice and it is always set to "Msvm_SyntheticMouse".
-
Description
-
-
Data type: string
-
Access type: Read-only
A textual description of the object. This property is inherited from CIM_ManagedElement and it is always set to "Microsoft Synthetic Mouse".
-
-
DeviceID
-
An address or other identifying information to uniquely name the logical device. This property is inherited from CIM_LogicalDevice and it is always set to "Microsoft:GUID".
-
ElementName
-
-
Data type: string
-
Access type: Read-only
A user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information. Note that the Name property of the CIM_ManagedSystemElement class is also defined as a user-friendly name. But, it is often subclassed to be a Key. It is not reasonable that the same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a Key (such as for instances of LogicalDevice), the same information can be present in both the Name and ElementName properties. This property is inherited from CIM_ManagedElement and it is always set to "Mouse".
-
-
EnabledDefault
-
-
Data type: uint16
-
Access type: Read/write
An administrator's default or startup configuration for the EnabledState of an element. This property is inherited from CIM_EnabledLogicalElement and it is always set to 2 (Enabled).
-
-
EnabledState
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.OtherEnabledState")
The enabled and disabled states of an element. This property is inherited from CIM_EnabledLogicalElement and it is set to 2 (Enabled) if the guest VM supports a synthetic mouse and 3 (Disabled) if it does not (for example, DOS).
-
-
Enabled (2)
-
Indicates that the element executes or could execute commands, processes any queued commands, and queues new requests.
-
Disabled (3)
ErrorCleared
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus")
This property is inherited from CIM_LogicalDevice but it is not used.
ErrorDescription
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.ErrorDescription")
This property is inherited from CIM_LogicalDevice but it is not used.
Handedness
-
Data type: uint16
-
Access type: Read-only
The configuration of the pointing device for right-hand or left-hand operation. This property is inherited from CIM_PointingDevice and it is always set to 2 (Right Handed Operation).
HealthState
-
Data type: uint16
-
Access type: Read-only
The current health of the element. This property is inherited from CIM_ManagedSystemElement and it is always set to 5 (OK).
OK (5)
The element is fully functional and operates within normal operational parameters and without error.
HorizontalPosition
-
Data type: sint32
-
Access type: Read-only
The absolute x-coordinate of the pointing device.
IdentifyingDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_LogicalDevice.OtherIdentifyingInfo")
An array of free-form strings that provide explanations and details behind the entries in the OtherIdentifyingInfo array. This property is inherited from CIM_LogicalDevice and it is always set to NULL.
InstallDate
-
Data type: datetime
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5")
The date and time at which the virtual system was created. This property is inherited from CIM_ManagedSystemElement.
IsLocked
-
Data type: boolean
-
Access type: Read-only
Indicates whether the device is locked, preventing user input or output. This property is inherited from CIM_UserDevice and it is set to False.
LastErrorCode
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.LastErrorCode")
This property is inherited from CIM_LogicalDevice but it is not used.
LocationIndicator
-
Data type: uint16
-
Access type: Read/write
-
Qualifiers: Experimental, ModelCorrespondence ("CIM_AlarmDevice.AlarmState", "CIM_AlarmDevice.AudioIndicatorIsDisabled", "CIM_AlarmDevice.VisualIndicatorIsDisabled", "CIM_AlarmDevice.MotionIndicatorIsDisabled")
The state of an indicator that is part of a device. This property is inherited from CIM_LogicalDevice and it is always set to 4 (Not Supported).
MaxQuiesceTime
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("No value"), Units ("MilliSeconds")
This property is inherited from CIM_LogicalDevice but it is not used.
Name
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (1024)
The label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement and it is always set to "Mouse".
NumberOfButtons
-
Data type: uint8
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIF.DMTF|Pointing Device|003.4")
The number of buttons on the pointing device. This property is inherited from CIM_PointingDevice and it is always set to 5.
OperationalStatus
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")
The current status of the element. This property is inherited from CIM_ManagedSystemElement and it is always set to 2 (OK).
OK (2)
Indicates full functionality without errors.
OtherEnabledState
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
The enabled or disabled state of the element when the EnabledState property is set to 1 (Other). This property must be set to NULL when EnabledState is any value other than 1. This property is inherited from CIM_EnabledLogicalElement and it is always set to NULL.
OtherIdentifyingInfo
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: MaxLen (256), ArrayType ("Indexed"), ModelCorrespondence ("CIM_LogicalDevice.IdentifyingDescriptions")
Any additional data, beyond device ID information, that could be used to identify a logical device. This property is inherited from CIM_LogicalDevice and it is always set to NULL.
PointingType
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIF.DMTF|Pointing Device|003.1")
The type of pointing device. This property is inherited from CIM_PointingDevice and it is always set to 3 (Mouse).
PowerManagementCapabilities
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities.PowerCapabilities")
This property is inherited from CIM_LogicalDevice but it is not used.
PowerManagementSupported
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities")
This property is inherited from CIM_LogicalDevice but it is not used.
PowerOnHours
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PoweredStatisticalData.PowerOnHours"), Units ("Hours"), Counter
This property is inherited from CIM_LogicalDevice but it is not used.
RequestedState
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
The last requested or desired state for the element. This property is inherited from CIM_EnabledLogicalElement and it is always set to 12.
Not Applicable (12)
Indicates that this instance does not support the RequestedState property.
Resolution
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Counts per Inch")
The resolution of the primary video surface. This property is inherited from CIM_PointingDevice.
ScrollPosition
-
Data type: sint32
-
Access type: Read-only
-
Qualifiers: Units ("Mickeys")
The z-coordinate position of the mouse device.
Status
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)
This property is inherited from CIM_ManagedSystemElement but it is not used.
StatusDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")
Strings that describe the various OperationalStatus array values. This property is inherited from CIM_ManagedSystemElement and it is always set to "OK".
StatusInfo
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_EnabledLogicalElement.EnabledState"), MappingStrings ("MIF.DMTF|Operational State|006.4")
This property is inherited from CIM_LogicalDevice but it is not used.
SystemCreationClassName
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key, Propagated ("CIM_System.CreationClassName"), MaxLen (256)
The creation class name of the scoping system. This property is inherited from CIM_LogicalDevice and it is always set to "Msvm_ComputerSystem".
SystemName
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key, Propagated ("CIM_System.Name"), MaxLen (256)
The name of the scoping system. This value corresponds to the value of the Name property of the Msvm_ComputerSystem class for the scoping virtual system. This property is inherited from CIM_LogicalDevice and it is always set to "GUID".
TimeOfLastStateChange
-
Data type: datetime
-
Access type: Read-only
The date or time when the enabled state of the element last changed. If the state of the element has not changed and this property is populated, then it must be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property must not be updated. This property is inherited from CIM_EnabledLogicalElement and it is always set to NULL.
TotalPowerOnHours
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PoweredStatisticalData.TotalPowerOnHours"), Units ("Hours"), Counter
This property is inherited from CIM_LogicalDevice but it is not used.
VerticalPosition
-
Data type: sint32
-
Access type: Read-only
The absolute y-coordinate of the pointing device.
Remarks
Access to the Msvm_SyntheticMouse class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 |
End of client support |
None supported |
End of server support |
Windows Server 2012 R2 |
Namespace |
Root\Virtualization |
MOF |
|