Bewerken

Delen via


Components collection

Contains an object for each component in the related application. The Components collection is always related to an object in the Applications collection. The properties exposed by these objects hold settings made at the component level.

This collection supports the Remove method of the COMAdminCatalogCollection object, but not the Add method. To install or import components into an application, use methods on the COMAdminCatalog object.

Members

The Components collection inherits from the IUnknown interface but does not have additional members.

You can navigate from this collection to any of the following collections:

You can navigate to this collection from the following collections:

Properties

The following properties are supported by the COMAdminCatalogObject object within the collection:

AllowInprocSubscribers

Entry Value
Description Enables in process subscribers if the component is an event class.
Access ReadWrite
Type Bool
Default True
Minimum system Windows 2000

 

ApplicationID

Entry Value
Description The GUID for the application containing the component. Must be a valid application's GUID, which is verified before SaveChanges is called. If this value is changed to be a GUID for a different application, the component moves to that application.
Access ReadWrite
Type String
Default N/A
Minimum system Windows 2000

 

Bitness

Entry Value
Description Represents the binary bitness type of a component. On systems that use 64-bit Windows, this property distinguishes between 64-bit components and 32-bit components.
Access ReadOnly
Type Long Possible values:COMAdmin32BitComponent (0x1)COMAdmin64BitComponent (0x2)
Default N/A
Minimum system Windows XP

 

CLSID

Entry Value
Description A GUID for the component. This property is returned when the Key property method is called on an object of this collection.
Access ReadOnly
Type String
Default N/A
Minimum system Windows 2000

 

ComponentAccessChecksEnabled

Entry Value
Description Indicates whether role-based access checks are performed on calls into the component and works in conjunction with the AccessChecksLevel and ApplicationAccessChecksEnabled properties on the application.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

ComponentTransactionTimeout

Entry Value
Description When used in a transaction, specifies the time period in which this component causes the transaction to time out. The default is 60 seconds and cannot be longer than 3600 seconds (1 hour). The time-out value can be set to 0, specifying an infinite transaction time-out period. For this property to be used, ComponentTransactionTimeoutEnabled must be True. The value of this property overrides the global transaction time-out specified by the TransactionTimeout property of the LocalComputer collection.
Access ReadWrite
Type Long (0-3600)
Default 60
Minimum system Windows 2000

 

ComponentTransactionTimeoutEnabled

Entry Value
Description Specifies whether the transaction time-out period is enabled for this component. By default, the transaction time-out feature is disabled. When this property is True, the time-out specified by ComponentTransactionTimeout is used. When this property is False, the time-out specified by the TransactionTimeout property of the LocalComputer collection is used.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

COMTIIntrinsics

Entry Value
Description Enables passing of context properties from the COM Transaction Integrator (COMTI) into the context for this class. The COMTI eases the task of wrapping mainframe transactions and business logic as COM components.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

ConstructionEnabled

Entry Value
Description Determines whether the ConstructorString is passed to the object when it is constructed.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

ConstructorString

Entry Value
Description Initialization string for component construction. You can create different objects from the same generic component by using object constructor strings. If ConstructionEnabled is False, this property is ignored.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

CreationTimeout

Entry Value
Description When creating the object, number of milliseconds before a time-out error is returned. The maximum time-out is 2147483647 milliseconds (about 25 days).
Access ReadWrite
Type Long (0-2147483647)
Default 0
Minimum system Windows 2000

 

Description

Entry Value
Description Describes the component.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

DLL

Entry Value
Description The name and path of the file containing the component.
Access ReadOnly
Type String
Default N/A
Minimum system Windows 2000

 

EventTrackingEnabled

Entry Value
Description Determines whether events are tracked. Events include actions such as application shutdown; object creation and release; object references, consistency, activation, and deactivation; method calls, returns, and exceptions; transaction startup, preparing to commit, and abort; resource dispenser connection, allocation, and recycling; thread allocation and recycling.
Access ReadWrite
Type Bool
Default True
Minimum system Windows 2000

 

ExceptionClass

Entry Value
Description The CLSID, which can be a GUID or a moniker string, to activate an alternative program during the process of dealing with a repeatedly failing queued components program.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

FireInParallel

Entry Value
Description Enables events to be fired in parallel if the component is an event class.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

IISIntrinsics

Entry Value
Description Enables passing of IIS context properties, such as an application session object or a user session object, into the context for this class.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

InitializeServerApplication

Entry Value
Description Indicates whether the component is used to initialize a server application.
Access ReadWrite
Type Bool
Default False
Minimum system Windows Server 2003

 

IsEnabled

Entry Value
Description False if the COM+ application or component is disabled. If the COM+ application or component is enabled, IsEnabled is True.
Access ReadWrite
Type Bool
Default True
Minimum system Windows XP

 

IsEventClass

Entry Value
Description Indicates whether the component is an event class.
Access ReadOnly
Type Bool
Default False
Minimum system Windows 2000

 

IsInstalled

Entry Value
Description Indicates whether the component is installed in an application.
Access ReadOnly
Type Bool
Default False
Minimum system Windows Server 2003

 

IsPrivateComponent

Entry Value
Description Determines whether a server application is a private component. A private component in a server application can be activated only from within the application. For example, if you call CoCreateInstance on a private component, it fails from out-of-process but succeeds in-process. In contrast, if you call CoCreateInstance on a public component, it succeeds both in-process and out-of-process.
Access ReadWrite
Type Bool
Default False
Minimum system Windows XP

 

JustInTimeActivation

Entry Value
Description Determines whether JIT activation is enabled for the component. This property is set to True when transaction support is set to Required, Requires New, or Supported. When JustInTimeActivation is set to True, synchronization support must be set to Required (the default) or Requires New.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

LoadBalancingSupported

Entry Value
Description If the component load balancing service is installed and enabled on the server, determines whether the component participates in load balancing.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

MaxPoolSize

Entry Value
Description Maximum number of objects pooled.
Access ReadWrite
Type Long (1-1048576)
Default 1048576
Minimum system Windows 2000

 

MinPoolSize

Entry Value
Description Minimum number of objects pooled.
Access ReadWrite
Type Long (0-1048576)
Default 0
Minimum system Windows 2000

 

MultiInterfacePublisherFilterCLSID

Entry Value
Description CLSID for the publisher filter used if the component is an event class.
Access ReadWrite
Type String
Default N/A
Minimum system Windows 2000

 

MustRunInClientContext

Entry Value
Description Indicates that component must be activated in its original caller's context. Otherwise, activation fails.
Access ReadWrite
Type Bool
Default False
Minimum system Windows XP

 

MustRunInDefaultContext

Entry Value
Description Indicates that the component must be activated in the default caller's context. Otherwise, activation fails.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

ObjectPoolingEnabled

Entry Value
Description Determines whether COM+ object pooling is enabled for the component.
Access ReadWrite
Type Bool
Default False
Minimum system Windows 2000

 

ProgID

Entry Value
Description A friendly name used for identifying the component. This property is returned when the Name property method is called on an object of this collection.
Access ReadOnly
Type String
Default N/A
Minimum system Windows 2000

 

PublisherID

Entry Value
Description Identifier for the event publisher if the component is an event class.
Access ReadWrite
Type String
Default ""
Minimum system Windows 2000

 

SoapAssemblyName

Entry Value
Description A GUID identifying the GAC assembly that is run when the component is invoked as a SOAP service.
Access ReadWrite
Type String
Default NULL
Minimum system Windows Server 2003

 

SoapTypeName

Entry Value
Description The managed type name for a component that can be invoked as a SOAP service.
Access ReadWrite
Type String
Default NULL
Minimum system Windows Server 2003

 

Synchronization

Entry Value
Description Determines call synchronization for the component.
Access ReadWrite
Type Long Possible values:COMAdminSynchronizationIgnored (0)COMAdminSynchronizationNone (1)COMAdminSynchronizationSupported (2)COMAdminSynchronizationRequired (3)COMAdminSynchronizationRequiresNew (4)
Default COMAdminSynchronizationIgnored (0)
Minimum system Windows 2000

 

ThreadingModel

Entry Value
Description Determines how instances of the component are assigned to threads for method execution. Values correspond to COM threading models.
Access ReadOnly
Type Long Possible values:COMAdminThreadingModelApartment (0)COMAdminThreadingModelFree (1)COMAdminThreadingModelMain (2)COMAdminThreadingModelBoth (3)COMAdminThreadingModelNeutral (4)COMAdminThreadingModelNotSpecified (5)
Default N/A
Minimum system Windows 2000

 

Transaction

Entry Value
Description Determines how a component supports transactions. It is recommended that you use the constants in the enumeration and not the numeric values.
Access ReadWrite
Type Long Possible values:COMAdminTransactionIgnored (0)COMAdminTransactionNone (1)COMAdminTransactionSupported (2)COMAdminTransactionRequired (3)COMAdminTransactionRequiresNew (4)
Default COMAdminTransactionNone (1)
Minimum system Windows 2000

 

TxIsolationLevel

Entry Value
Description Indicates the transaction isolation levels. There are five isolation levels: none, read uncommitted, read committed, repeatable read, and serialized. The default isolation level is serialized.
Access ReadWrite
Type Long Possible values:COMAdminTxIsolationLevelAny (0)COMAdminTxIsolationLevelReadUnCommitted (1)COMAdminTxIsolationLevelReadCommitted (2)COMAdminTxIsolationLevelRepeatableRead (3)COMAdminTxIsolationLevelSerializable (4)
Default COMAdminTxIsolationLevelSerializable (4)
Minimum system Windows XP

 

VersionBuild

Entry Value
Description Version build identifier.
Access ReadOnly
Type String
Default ""
Minimum system Windows 2000

 

VersionMajor

Entry Value
Description Version identifier.
Access ReadOnly
Type String
Default ""
Minimum system Windows 2000

 

VersionMinor

Entry Value
Description Version sub-identifier.
Access ReadOnly
Type String
Default ""
Minimum system Windows 2000

 

VersionSubBuild

Entry Value
Description Version sub-build identifier.
Access ReadOnly
Type String
Default ""
Minimum system Windows 2000

 

See also

COM+ Administration Collections