Uredi

Deli z drugimi prek


ToolZone.HeaderCloseVerb Property

Definition

Gets a reference to the WebPartVerb object in the header of a ToolZone control that is used to close the control.

public:
 virtual property System::Web::UI::WebControls::WebParts::WebPartVerb ^ HeaderCloseVerb { System::Web::UI::WebControls::WebParts::WebPartVerb ^ get(); };
[System.Web.UI.PersistenceMode(System.Web.UI.PersistenceMode.InnerProperty)]
public virtual System.Web.UI.WebControls.WebParts.WebPartVerb HeaderCloseVerb { get; }
[<System.Web.UI.PersistenceMode(System.Web.UI.PersistenceMode.InnerProperty)>]
member this.HeaderCloseVerb : System.Web.UI.WebControls.WebParts.WebPartVerb
Public Overridable ReadOnly Property HeaderCloseVerb As WebPartVerb

Property Value

The WebPartVerb used to close a ToolZone control.

Attributes

Examples

The following code example shows how to use the HeaderCloseVerb property with an inherited ToolZone control. The example shows how to enable and disable the close verb in the header of an EditorZone control.

The first part of the code example is a user control that is referenced in the page, and enables you to switch the page to different display modes. For more information on display modes and enabling users to switch among them, see Walkthrough: Changing Display Modes on a Web Parts Page.

<%@ control language="C#" classname="DisplayModeMenuCS"%>
<script runat="server">
  
 // Use a field to reference the current WebPartManager.
  WebPartManager _manager;

  void Page_Init(object sender, EventArgs e)
  {
    Page.InitComplete += new EventHandler(InitComplete);
  }  

  void InitComplete(object sender, System.EventArgs e)
  {
    _manager = WebPartManager.GetCurrentWebPartManager(Page);

    String browseModeName = WebPartManager.BrowseDisplayMode.Name;

    // Fill the dropdown with the names of supported display modes.
    foreach (WebPartDisplayMode mode in _manager.SupportedDisplayModes)
    {
      String modeName = mode.Name;
      // Make sure a mode is enabled before adding it.
      if (mode.IsEnabled(_manager))
      {
        ListItem item = new ListItem(modeName, modeName);
        DisplayModeDropdown.Items.Add(item);
      }
    }

    // If shared scope is allowed for this user, display the scope-switching
    // UI and select the appropriate radio button for the current user scope.
    if (_manager.Personalization.CanEnterSharedScope)
    {
      Panel2.Visible = true;
      if (_manager.Personalization.Scope == PersonalizationScope.User)
        RadioButton1.Checked = true;
      else
        RadioButton2.Checked = true;
    }
    
  }
 
  // Change the page to the selected display mode.
  void DisplayModeDropdown_SelectedIndexChanged(object sender, EventArgs e)
  {
    String selectedMode = DisplayModeDropdown.SelectedValue;

    WebPartDisplayMode mode = _manager.SupportedDisplayModes[selectedMode];
    if (mode != null)
      _manager.DisplayMode = mode;
  }

  // Set the selected item equal to the current display mode.
  void Page_PreRender(object sender, EventArgs e)
  {
    ListItemCollection items = DisplayModeDropdown.Items;
    int selectedIndex = 
      items.IndexOf(items.FindByText(_manager.DisplayMode.Name));
    DisplayModeDropdown.SelectedIndex = selectedIndex;
  }

  // Reset all of a user's personalization data for the page.
  protected void LinkButton1_Click(object sender, EventArgs e)
  {
    _manager.Personalization.ResetPersonalizationState();
  }

  // If not in User personalization scope, toggle into it.
  protected void RadioButton1_CheckedChanged(object sender, EventArgs e)
  {
    if (_manager.Personalization.Scope == PersonalizationScope.Shared)
      _manager.Personalization.ToggleScope();
  }

  // If not in Shared scope, and if user is allowed, toggle the scope.
  protected void RadioButton2_CheckedChanged(object sender, EventArgs e)
  {
    if (_manager.Personalization.CanEnterSharedScope && 
        _manager.Personalization.Scope == PersonalizationScope.User)
      _manager.Personalization.ToggleScope();
  }
</script>
<div>
  <asp:Panel ID="Panel1" runat="server" 
    Borderwidth="1" 
    Width="230" 
    BackColor="lightgray"
    Font-Names="Verdana, Arial, Sans Serif" >
    <asp:Label ID="Label1" runat="server" 
      Text=" Display Mode" 
      Font-Bold="true"
      Font-Size="8"
      Width="120" 
      AssociatedControlID="DisplayModeDropdown"/>
    <asp:DropDownList ID="DisplayModeDropdown" runat="server"  
      AutoPostBack="true" 
      Width="120"
      OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
    <asp:LinkButton ID="LinkButton1" runat="server"
      Text="Reset User State" 
      ToolTip="Reset the current user's personalization data for the page."
      Font-Size="8" 
      OnClick="LinkButton1_Click" />
    <asp:Panel ID="Panel2" runat="server" 
      GroupingText="Personalization Scope"
      Font-Bold="true"
      Font-Size="8" 
      Visible="false" >
      <asp:RadioButton ID="RadioButton1" runat="server" 
        Text="User" 
        AutoPostBack="true"
        GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
      <asp:RadioButton ID="RadioButton2" runat="server" 
        Text="Shared" 
        AutoPostBack="true"
        GroupName="Scope" 
        OnCheckedChanged="RadioButton2_CheckedChanged" />
    </asp:Panel>
  </asp:Panel>
</div>
<%@ control language="vb" classname="DisplayModeMenuVB"%>
<script runat="server">
  ' Use a field to reference the current WebPartManager.
  Dim _manager As WebPartManager

  Sub Page_Init(ByVal sender As Object, ByVal e As EventArgs)
    AddHandler Page.InitComplete, AddressOf InitComplete
  End Sub

  Sub InitComplete(ByVal sender As Object, ByVal e As System.EventArgs)
    _manager = WebPartManager.GetCurrentWebPartManager(Page)
      
    Dim browseModeName As String = WebPartManager.BrowseDisplayMode.Name
      
    ' Fill the dropdown with the names of supported display modes.
    Dim mode As WebPartDisplayMode
    For Each mode In _manager.SupportedDisplayModes
      Dim modeName As String = mode.Name
      ' Make sure a mode is enabled before adding it.
      If mode.IsEnabled(_manager) Then
        Dim item As New ListItem(modeName, modeName)
        DisplayModeDropdown.Items.Add(item)
      End If
    Next mode
      
    ' If shared scope is allowed for this user, display the scope-switching
    ' UI and select the appropriate radio button for the current user scope.
    If _manager.Personalization.CanEnterSharedScope Then
      Panel2.Visible = True
      If _manager.Personalization.Scope = PersonalizationScope.User Then
        RadioButton1.Checked = True
      Else
        RadioButton2.Checked = True
      End If
    End If
   
  End Sub

  ' Change the page to the selected display mode.
  Sub DisplayModeDropdown_SelectedIndexChanged(ByVal sender As Object, _
    ByVal e As EventArgs)
    
    Dim selectedMode As String = DisplayModeDropdown.SelectedValue   
    Dim mode As WebPartDisplayMode = _
      _manager.SupportedDisplayModes(selectedMode)
    If Not (mode Is Nothing) Then
      _manager.DisplayMode = mode
    End If

  End Sub
   
  ' Set the selected item equal to the current display mode.
  Sub Page_PreRender(ByVal sender As Object, ByVal e As EventArgs)
    Dim items As ListItemCollection = DisplayModeDropdown.Items
    Dim selectedIndex As Integer = _
      items.IndexOf(items.FindByText(_manager.DisplayMode.Name))
    DisplayModeDropdown.SelectedIndex = selectedIndex

  End Sub

  ' Reset all of a user's personalization data for the page.
  Protected Sub LinkButton1_Click(ByVal sender As Object, _
    ByVal e As EventArgs)
    
    _manager.Personalization.ResetPersonalizationState()
    
  End Sub

  ' If not in User personalization scope, toggle into it.
  Protected Sub RadioButton1_CheckedChanged(ByVal sender As Object, _
    ByVal e As EventArgs)
    
    If _manager.Personalization.Scope = PersonalizationScope.Shared Then
      _manager.Personalization.ToggleScope()
    End If

  End Sub
   
  ' If not in Shared scope, and if user is allowed, toggle the scope.
  Protected Sub RadioButton2_CheckedChanged(ByVal sender As Object, _
    ByVal e As EventArgs)
    
    If _manager.Personalization.CanEnterSharedScope AndAlso _
      _manager.Personalization.Scope = PersonalizationScope.User Then
      _manager.Personalization.ToggleScope()
    End If

  End Sub

</script>
<div>
  <asp:Panel ID="Panel1" runat="server" 
    Borderwidth="1" 
    Width="230" 
    BackColor="lightgray"
    Font-Names="Verdana, Arial, Sans Serif" >
    <asp:Label ID="Label1" runat="server" 
      Text=" Display Mode" 
      Font-Bold="true"
      Font-Size="8"
      Width="120" 
      AssociatedControlID="DisplayModeDropdown"/>
    <asp:DropDownList ID="DisplayModeDropdown" runat="server"  
      AutoPostBack="true" 
      Width="120"
      OnSelectedIndexChanged="DisplayModeDropdown_SelectedIndexChanged" />
    <asp:LinkButton ID="LinkButton1" runat="server"
      Text="Reset User State" 
      ToolTip="Reset the current user's personalization data for the page."
      Font-Size="8" 
      OnClick="LinkButton1_Click" />
    <asp:Panel ID="Panel2" runat="server" 
      GroupingText="Personalization Scope"
      Font-Bold="true"
      Font-Size="8" 
      Visible="false" >
      <asp:RadioButton ID="RadioButton1" runat="server" 
        Text="User" 
        AutoPostBack="true"
        GroupName="Scope" OnCheckedChanged="RadioButton1_CheckedChanged" />
      <asp:RadioButton ID="RadioButton2" runat="server" 
        Text="Shared" 
        AutoPostBack="true"
        GroupName="Scope" 
        OnCheckedChanged="RadioButton2_CheckedChanged" />
    </asp:Panel>
  </asp:Panel>
</div>

The second part of the code example is the Web page. The page contains an EditorZone control, which inherits from the ToolZone class. The Button1_Click method in the page sets the HeaderCloseVerb property value.

Note that after the page loads, you must switch the page into edit mode to see the effects of the code that uses the HeaderCloseVerb property on the EditorZone control. As you click the Enable/Disable Close Verb button, the verb in the header of the zone should be alternately enabled and disabled.

<%@ Page Language="C#" %>
<%@ register TagPrefix="uc1" 
  TagName="DisplayModeMenuCS" 
  Src="DisplayModeMenuCS.ascx" %>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
    "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >

<script runat="server">

  void Button1_Click(object sender, EventArgs e)
  {
    bool EnableClose = false;
    if(!EditorZone1.HeaderCloseVerb.Enabled)
      EnableClose = true;
    EditorZone1.HeaderCloseVerb.Enabled = EnableClose;
  }
</script>
<head runat="server">
    <title>Tool Zone Example</title>
</head>
<body>
    <form id="form1" runat="server">
    <div>
      <asp:WebPartManager ID="WebPartManager1" Runat="server" />
      <uc1:DisplayModeMenuCS ID="DisplayModeMenu1" runat="server" />
      <asp:WebPartZone ID="WebPartZone1" Runat="server" >
        <ZoneTemplate>
          <asp:BulletedList 
            ID="BulletedList1" 
            Runat="server"
            DisplayMode="HyperLink" 
            Title="Favorite Links" >
            <asp:ListItem Value="http://msdn.microsoft.com">MSDN</asp:ListItem>
            <asp:ListItem Value="http://www.asp.net">ASP.NET</asp:ListItem>
            <asp:ListItem Value="http://www.msn.com">MSN</asp:ListItem>
          </asp:BulletedList>
        </ZoneTemplate>
      </asp:WebPartZone>
      <asp:EditorZone 
        ID="EditorZone1" 
        Runat="server">
        <HeaderCloseVerb Text="End Editing" />
        <ZoneTemplate>
          <asp:AppearanceEditorPart ID="AppearanceEditorPart1" Runat="server" />
          <asp:LayoutEditorPart ID="LayoutEditorPart1" Runat="server" /> 
        </ZoneTemplate>
      </asp:EditorZone>
      <asp:Button ID="Button1" Runat="server" 
        Text="Enable/Disable Close Verb" 
        OnClick="Button1_Click" />
      </div>
    </form>
</body>
</html>
<%@ Page Language="VB" %>
<%@ register TagPrefix="uc1" 
  TagName="DisplayModeMenuVB" 
  Src="DisplayModeMenuVB.ascx" %>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
    "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >

<script runat="server">
  Sub Button1_Click(ByVal sender As Object, ByVal e As EventArgs)
    Dim EnableClose as Boolean = false
    If EditorZone1.HeaderCloseVerb.Enabled = False Then
      EnableClose = True
    End If
    EditorZone1.HeaderCloseVerb.Enabled = EnableClose
  End Sub
</script>
<head runat="server">
    <title>Tool Zone Example</title>
</head>
<body>
    <form id="form1" runat="server">
    <div>
      <asp:WebPartManager ID="WebPartManager1" Runat="server" />
      <uc1:DisplayModeMenuVB ID="DisplayModeMenu1" runat="server" />
      <asp:WebPartZone ID="WebPartZone1" Runat="server" >
        <ZoneTemplate>
          <asp:BulletedList 
            ID="BulletedList1" 
            Runat="server"
            DisplayMode="HyperLink" 
            Title="Favorite Links" >
            <asp:ListItem Value="http://msdn.microsoft.com">MSDN</asp:ListItem>
            <asp:ListItem Value="http://www.asp.net">ASP.NET</asp:ListItem>
            <asp:ListItem Value="http://www.msn.com">MSN</asp:ListItem>
          </asp:BulletedList>
        </ZoneTemplate>
      </asp:WebPartZone>
      <asp:EditorZone 
        ID="EditorZone1" 
        Runat="server">
        <HeaderCloseVerb Text="End Editing" />
        <ZoneTemplate>
          <asp:AppearanceEditorPart ID="AppearanceEditorPart1" Runat="server" />
          <asp:LayoutEditorPart ID="LayoutEditorPart1" Runat="server" /> 
        </ZoneTemplate>
      </asp:EditorZone>
      <asp:Button ID="Button1" Runat="server" 
        Text="Enable/Disable Close Verb" 
        OnClick="Button1_Click" />
      </div>
    </form>
</body>
</html>

Remarks

You can use the HeaderCloseVerb property programmatically or in the declarative markup of a Web page to specify various attributes for the verb that is used to close a ToolZone control.

Applies to

See also