Information for diagnosing and resolving WCF Send errors.

Failed to generate ODX file

Field Error Details
Product Name BizTalk Server
Product Version 3.6
Event ID 0
Event Source 0
Component 0
Symbolic Name 0
Message Text Failed to generate ODX file

Explanation

This error indicates there was an error in consuming the service.

User Action

Check that the service has valid Web Method and that metadata is hosted (if you own the WCF services). Otherwise, contact the service provider.

For additional information on consuming WCF services, see Considerations When Consuming WCF Services with the WCF Send Adapters.

Response message body was not read

Field Error Details
Product Name BizTalk Server
Product Version 3.6
Event ID 0
Event Source 0
Component 0
Symbolic Name 0
Message Text The response message body was not read (This may indicate the connection has been closed.)

Explanation

The client may be disconnected before the response message is sent back.

User Action

Check the client connectivity. The steps taken, and the extent of the action, will depend on the port type.