SMS_DistributionPointInfo server WMI class
The SMS_DistributionPointInfo
WMI class is an SMS Provider server class in Configuration Manager. It provides information about a specific SMS_DistributionPoint server WMI class object.
Class SMS_DistributionPointInfo : SMS_BaseClass
{
Boolean AddressScheduleEnabled;
String BindExcept;
Boolean BindPolicy;
Boolean BitsEnabled;
Boolean CertificateType;
UInt32 Communication;
String Description;
UInt32 DPFlags;
String Drive;
UInt32 GroupCount;
Boolean HasRelationship;
Boolean HealthCheckEnabled;
UInt32 HealthCheckPriority;
String HealthCheckSchedule;
UInt32 ID;
String IdentityGUID;
Boolean InternetFacing;
Boolean IsActive;
Boolean IsMulticast;
Boolean IsPeerDP;
Boolean IsProtected;
Boolean IsPullDP;
Boolean IsPXE;
String NALPath;
String Name;
String OperatingSystem;
UInt32 Priority;
Boolean PreStagingAllowed;
String PXEPassword;
Boolean RateLimitsEnabled;
UInt32 Region;
String ResourceType;
UInt32 ResponseDelay;
String ServerName;
String ServiceType;
String ShareName;
String SiteCode;
String SiteName;
Boolean SupportUnknownMachines;
UInt32 TransferRate;
UInt32 UdaSetting;
};
The following table lists the methods in the SMS_DistributionPointInfo
class.
Method | Description |
---|---|
GetChainedPullDPs Method in Class SMSDistributionPointInfo | Ensures that when a source distribution point is assigned, a looping chain is not generated. |
SetDPMaintenanceMode method in class SMS_DistributionPointInfo | Starting in version 1902, put a distribution point in maintenance mode. |
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if a schedule on this address is configured.
Data type: String
Access type: Read/Write
Qualifiers: none
PXE bind exception.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
PXE bind policy.
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the distribution point is BITS-enabled. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
PXE certificate type.
Data type: UInt32
Access type: Read/Write
Qualifiers: none
HTTP or HTTPS. The default value is 0.
Data type: String
Access type: Read/Write
Qualifiers: None
Description of the distribution point.
Data type: UInt32
Access type: Read-only
Qualifiers: [enumeration, read]
Distribution point flags.
Value | Distribution point flag |
---|---|
0 | DP_TYPE_READONLY |
Data type: String
Access type: Read/Write
Qualifiers: None
Drive that's to be used by the distribution point. The default value is "".
Data type: UInt32
Access type: Read/Write
Qualifiers: none
Count of distribution point groups that have this distribution point.
Data type: Boolean
Access type: Read-only
Qualifiers: [read]
true
if this distribution point is assigned to a distribution point group.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if health check on this distribution point is enabled.
Data type: UInt32
Access type: Read/Write
Qualifiers: none
Distribution point health thread manager thread priority. The default value is 4.
Data type: String
Access type: Read/Write
Qualifiers: none
Schedule for health check.
Data type: UInt32
Access type: Read-only
Qualifiers: [read]
Distribution point ID. This value is stored in the database. The default value is 0.
Data type: String
Access type: Read/Write
Qualifiers: none
The distribution point identity, generated at the distribution point installation time. It's a GUID in ClientKeyData
that identifies the distribution point. The GUID is associated with a certificate.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if this distribution point is internet-facing. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if this PXE is active. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if multicast is enabled on this distribution point. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the distribution point is a branch distribution point. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true
if the distribution point site system is protected. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if the distribution point is a pull distribution point. The default value is false
.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if PXE is enabled. The default value is false
.
Data type: String
Access type: Read/Write
Qualifiers: [key]
Network abstraction layer (NAL) path to the distribution point. The default value is "".
Data type: String
Access type: Read-only
Qualifiers: [read]
Network operating system path.
Data type: String
Access type: Read/Write
Qualifiers: none
The OS of this computer.
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if pre-staging is allowed.
Data type: UInt32
Access type: Read/Write
Qualifiers: none
Distribution priority. The default value is 1.
Data type: String
Access type: Read/Write
Qualifiers: none
PXE password. The default value is "".
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if rate limits are enabled.
Data type: String
Access type: Read/Write
Qualifiers: none
The Azure region in which the cloud-based distribution point resides.
Data type: String
Access type: Read/Write
Qualifiers: [key]
Resource type of the distribution point. The default value is "". The possible values are:
Server
Server share
Data type: UInt32
Access type: Read/Write
Qualifiers: none
PXE response delay.
Data type: String
Access type: Read/Write
Qualifiers: None
Server name of the distribution point computer. The default value is "".
Data type: UInt32
Access type: Read/Write
Qualifiers: none
Service type. For cloud-based distribution points only.
Data type: String
Access type: Read/Write
Qualifiers: None
Obsolete. Shared distribution points aren't supported in Configuration Manager.
Data type: String
Access type: Read/Write
Qualifiers: [key, SizeLimit("3")]
Site code of the site that owns the distribution point. The default value is "".
Data type: String
Access type: Read/Write
Qualifiers: None
Site name. The default value is "".
Data type: Boolean
Access type: Read/Write
Qualifiers: none
true
if PXE supports unknown computers. The default value is false
.
Data type: UInt32
Access type: Read/Write
Qualifiers: none
The average transfer rate in Kbps. The default value is 0.
Data type: UInt32
Access type: Read/Write
Qualifiers: none
PXE user-device affinity (UDA) setting.
Class qualifiers for this class include:
- Read (read-only)
For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager class and property qualifiers.
For more information, see Configuration Manager server runtime requirements.
For more information, see Configuration Manager server development requirements.