LPHANDLER_FUNCTION_EX callback function (winsvc.h)
An application-defined callback function used with the RegisterServiceCtrlHandlerEx function. A service program can use it as the control handler function of a particular service.
The LPHANDLER_FUNCTION_EX type defines a pointer to this function. HandlerEx is a placeholder for the application-defined name.
This function supersedes the Handler control handler function used with the RegisterServiceCtrlHandler function. A service can use either control handler, but the new control handler supports user-defined context data and additional extended control codes.
LPHANDLER_FUNCTION_EX LphandlerFunctionEx;
DWORD LphandlerFunctionEx(
[in] DWORD dwControl,
[in] DWORD dwEventType,
[in] LPVOID lpEventData,
[in] LPVOID lpContext
)
{...}
[in] dwControl
The control code. This parameter can be one of the following values.
Control code | Meaning |
---|---|
|
Notifies a paused service that it should resume. |
|
Notifies a service to report its current status information to the service control manager.
The handler should simply return NO_ERROR; the SCM is aware of the current state of the service. |
|
Notifies a network service that there is a new component for binding. The service should bind to the new
component.
Applications should use Plug and Play functionality instead. |
|
Notifies a network service that one of its bindings has been disabled. The service should reread its
binding information and remove the binding.
Applications should use Plug and Play functionality instead. |
|
Notifies a network service that a disabled binding has been enabled. The service should reread its
binding information and add the new binding.
Applications should use Plug and Play functionality instead. |
|
Notifies a network service that a component for binding has been removed. The service should reread its
binding information and unbind from the removed component.
Applications should use Plug and Play functionality instead. |
|
Notifies a service that service-specific startup parameters have changed. The service should reread its startup parameters. |
|
Notifies a service that it should pause. |
|
Notifies a service that the system will be shutting down. Services that need additional time to perform
cleanup tasks beyond the tight time restriction at system shutdown can use this notification. The service
control manager sends this notification to applications that have registered for it before sending a
SERVICE_CONTROL_SHUTDOWN notification to applications that have registered for that notification.
A service that handles this notification blocks system shutdown until the service stops or the preshutdown time-out interval specified through SERVICE_PRESHUTDOWN_INFO expires. Because this affects the user experience, services should use this feature only if it is absolutely necessary to avoid data loss or significant recovery time at the next system start. Windows Server 2003 and Windows XP: This value is not supported. |
|
Notifies a service that the system is shutting down so the service can perform cleanup tasks. Note that
services that register for SERVICE_CONTROL_PRESHUTDOWN notifications cannot receive this notification because
they have already stopped.
If a service accepts this control code, it must stop after it performs its cleanup tasks and return NO_ERROR. After the SCM sends this control code, it will not send other control codes to the service. For more information, see the Remarks section of this topic. |
|
Notifies a service that it should stop.
If a service accepts this control code, it must stop upon receipt and return NO_ERROR. After the SCM sends this control code, it will not send other control codes to the service. Windows XP: If the service returns NO_ERROR and continues to run, it continues to receive control codes. This behavior changed starting with Windows Server 2003 and Windows XP with SP2. |
This parameter can also be one of the following extended control codes. Note that these control codes are not supported by the Handler function.
Control Code | Meaning |
---|---|
|
Notifies a service of device events. (The service must have registered to receive these notifications using the RegisterDeviceNotification function.) The dwEventType and lpEventData parameters contain additional information. |
|
Notifies a service that the computer's hardware profile has changed. The dwEventType parameter contains additional information. |
|
Notifies a service of system power events. The dwEventType parameter contains additional information. If dwEventType is PBT_POWERSETTINGCHANGE, the lpEventData parameter also contains additional information. |
|
Notifies a service of session change events. Note that a service will only be notified of a user logon if it is fully loaded before the logon attempt is made. The dwEventType and lpEventData parameters contain additional information. |
|
Notifies a service that the system time has changed. The lpEventData parameter contains additional information. The dwEventType parameter is not used.
Windows Server 2008, Windows Vista, Windows Server 2003 and Windows XP: This control code is not supported. |
|
Notifies a service registered for a service trigger event that the event has occurred.
Windows Server 2008, Windows Vista, Windows Server 2003 and Windows XP: This control code is not supported. |
|
Notifies a service that the user has initiated a reboot.
Windows Server 2008 R2, Windows 7, Windows Server 2008, Windows Vista, Windows Server 2003 and Windows XP: This control code is not supported. |
This parameter can also be a user-defined control code, as described in the following table.
Control code | Meaning |
---|---|
|
The service defines the action associated with the control code. |
[in] dwEventType
The type of event that has occurred. This parameter is used if dwControl is SERVICE_CONTROL_DEVICEEVENT, SERVICE_CONTROL_HARDWAREPROFILECHANGE, SERVICE_CONTROL_POWEREVENT, or SERVICE_CONTROL_SESSIONCHANGE. Otherwise, it is zero.
If dwControl is SERVICE_CONTROL_DEVICEEVENT, this parameter can be one of the following values:
- DBT_DEVICEARRIVAL
- DBT_DEVICEREMOVECOMPLETE
- DBT_DEVICEQUERYREMOVE
- DBT_DEVICEQUERYREMOVEFAILED
- DBT_DEVICEREMOVEPENDING
- DBT_CUSTOMEVENT
If dwControl is SERVICE_CONTROL_SESSIONCHANGE, this parameter can be one of the values specified in the wParam parameter of the WM_WTSSESSION_CHANGE message.
[in] lpEventData
Additional device information, if required. The format of this data depends on the value of the dwControl and dwEventType parameters.
If dwControl is SERVICE_CONTROL_DEVICEEVENT, this data corresponds to the lParam parameter that applications receive as part of a WM_DEVICECHANGE message.
If dwControl is SERVICE_CONTROL_POWEREVENT and dwEventType is PBT_POWERSETTINGCHANGE, this data is a pointer to a POWERBROADCAST_SETTING structure.
If dwControl is SERVICE_CONTROL_SESSIONCHANGE, this parameter is a pointer to a WTSSESSION_NOTIFICATION structure.
If dwControl is SERVICE_CONTROL_TIMECHANGE, this data is a pointer to a SERVICE_TIMECHANGE_INFO structure.
[in] lpContext
User-defined data passed from RegisterServiceCtrlHandlerEx. When multiple services share a process, the lpContext parameter can help identify the service.
The return value for this function depends on the control code received.
The following list identifies the rules for this return value:
- In general, if your service does not handle the control, return ERROR_CALL_NOT_IMPLEMENTED. However, your service should return NO_ERROR for SERVICE_CONTROL_INTERROGATE even if your service does not handle it.
- If your service handles SERVICE_CONTROL_STOP or SERVICE_CONTROL_SHUTDOWN, return NO_ERROR.
- If your service handles SERVICE_CONTROL_DEVICEEVENT, return NO_ERROR to grant the request and an error code to deny the request.
- If your service handles SERVICE_CONTROL_HARDWAREPROFILECHANGE, return NO_ERROR to grant the request and an error code to deny the request.
- If your service handles SERVICE_CONTROL_POWEREVENT, return NO_ERROR to grant the request and an error code to deny the request.
- For all other control codes your service handles, return NO_ERROR.
When a service is started, its ServiceMain function should immediately call the RegisterServiceCtrlHandlerEx function to specify a HandlerEx function to process control requests. To specify the control codes to be accepted, use the SetServiceStatus and RegisterDeviceNotification functions.
The control dispatcher in the main thread of a service invokes the control handler function for the specified service whenever it receives a control request from the service control manager. After processing the control request, the control handler must call SetServiceStatus if the service state changes to report its new status to the service control manager.
The control handler function is intended to receive notification and return immediately. The callback function should save its parameters and create other threads to perform additional work. (Your application must ensure that such threads have exited before stopping the service.) In particular, a control handler should avoid operations that might block, such as taking a lock, because this could result in a deadlock or cause the system to stop responding.
When the service control manager sends a control code to a service, it waits for the handler function to return before sending additional control codes to other services. The control handler should return as quickly as possible; if it does not return within 30 seconds, the SCM returns an error. If a service must do lengthy processing when the service is executing the control handler, it should create a secondary thread to perform the lengthy processing, and then return from the control handler. This prevents the service from tying up the control dispatcher and blocking other services from receiving control codes.
The SERVICE_CONTROL_SHUTDOWN control code should only be processed by services that must absolutely clean up during shutdown, because there is a limited time (about 20 seconds) available for service shutdown. After this time expires, system shutdown proceeds regardless of whether service shutdown is complete. Note that if the system is left in the shutdown state (not restarted or powered down), the service continues to run. If your service registers to accept SERVICE_CONTROL_SHUTDOWN, it must handle the control code and return NO_ERROR. Returning an error for this control code and not stopping in a timely fashion can increase the time required to shut down the system, because the system must wait for the full amount of time allowed for service shutdown before system shutdown can proceed.
If the service requires more time to clean up, it should send STOP_PENDING status messages, along with a wait hint, so the service controller knows how long to wait before reporting to the system that service shutdown is complete. However, to prevent a service from stopping shutdown, there is a limit to how long the service controller waits. If the service is being shut down through the Services snap-in, the limit is 125 seconds. If the operating system is rebooting, the time limit is specified in the WaitToKillServiceTimeout value of the following registry key:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
Be sure to handle Plug and Play device events as quickly as possible; otherwise, the system may become unresponsive. If your event handler is to perform an operation that may block execution (such as I/O), it is best to start another thread to perform the operation asynchronously.
Services can also use the SetConsoleCtrlHandler function to receive shutdown notification. This notification is received when the running applications are shutting down, which occurs before services are shut down.
Requirement | Value |
---|---|
Minimum supported client | Windows XP [desktop apps only] |
Minimum supported server | Windows Server 2003 [desktop apps only] |
Target Platform | Windows |
Header | winsvc.h (include Windows.h) |