ScannerStatusConditionEvent element
The required ScannerStatusConditionEvent element provides the client with detailed information about a single status change in the scan device.
Usage
<wscn:ScannerStatusConditionEvent>
child elements
</wscn:ScannerStatusConditionEvent>
Attributes
There are no attributes.
Child elements
Element |
---|
DeviceCondition |
Parent elements
There are no parent elements.
Remarks
The WSD Scan Service sends a ScannerStatusConditionEvent element to a client when a DeviceCondition element is added or changed in the ActiveConditions element table. The body of ScannerStatusConditionEvent contains the new or changed DeviceCondition element.
The WSD Scan Service should send a ScannerStatusConditionClearedEvent element to the client when the reported DeviceCondition has been cleared.
Examples
The following code example shows how the scan device notifies the client about a scan lamp failure.
<soap:Envelope
xmlns:soap="https://www.w3.org/2003/05/soap-envelope"
xmlns:wsa="https://schemas.xmlsoap.org/ws/2004/08/addressing"
xmlns:wse="https://schemas.xmlsoap.org/ws/2004/08/eventing"
xmlns:wscn="https://schemas.microsoft.com/windows/2006/01/wdp/scan"
soap:encodingStyle='https://www.w3.org/2002/12/soap-encoding'>
<soap:Header>
<wsa:To>AddressofEventSink</wsa:To>
<wsa:Action>
https://schemas.microsoft.com/windows/2006/01/wdp/scan/ScannerStatusConditionEvent
</wsa:Action>
<wsa:MessageID>uuid:UniqueMsgId</wsa:MessageID>
</soap:Header>
<soap:Body>
<wscn:ScannerStatusConditionEvent>
<wscn:DeviceCondition wscn:Id="1543">
<wscn:Time>2006-01-21T17:22:27.5242689Z</wscn:Time>
<wscn:Name>LampError</wscn:Name>
<wscn:Component>Platen</wscn:Component>
<wscn:Severity>Critical</wscn:Severity>
</wscn:DeviceCondition>
</wscn:ScannerStatusConditionEvent>
</soap:Body